The text of a manual · part 4 of 5

timeQplus BIOMETRIC Terminal User Manual (TQ100 Terminal User Manual), pages 28 to 36

Pages 28 to 36 of 44

The original document is the PDF (881 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Acroprint TQ100

Page 28

7.1.6 Select View Admin Records menu and press OK to access the level-3 menu as follows:

User Finger Password FP+PW

ViewAdmin ID ESC

Press OK to display the following:

00000 Confirm -OK

Press OK to display the following:

After entering the administrator user ID number, press OK to display the following:

Finger New Enroll?

ViewAdmin 05/05/20 02:45 ESC

T-00001 L-00001 E_M

No-ESC Figure A Press OK to display the following:

Confirm -OK

Note: T-00001: Total number of admin events is 1 L-00001: The last recorded admin event 05/05/20 20:45: Admin/setup time E_M: indicates type of admin operation performed (see 7.1.8 below) The interface displays the total occurrences when the administrator has managed/setup the machine, the detailed time of each occurrence, and type of operation performed. 7.1.7 Select Delete All Records menu and press OK to access the level-3 menu as follows:

Delete All Rec Delete? No-ESC

Yes-OK

Yes-OK

Note: When the command “Delete all records” is confirmed, all the records stored on the terminal will be deleted.

New Enroll

Note: ID range can be any combination of numbers from 00001 - 65535

ID 00001 ESC

Set-OK

In the process of enrolling employee’s passwords, when the user ID is introduced, the zero digits located at the beginning of the number sequence are not required to key in. Example: If the user ID number is “0050”, the user needs to key in only “50”. Accept the user ID displayed or key in a user ID and press OK to display the following:

New Enroll Place Finger #1

Press OK to delete all records, press ESC to cancel and exit.

28 timeQplus BIOMETRIC™ Terminal User Manual timeQplus BIOMETRIC™ Terminal User Manual

17

Page 29

5.2 Fingerprint Registration

7.1.8 Display Messaging

There are two registration modes available for the terminal: fingerprint and password.

1. When viewing punches, the initials displayed on the interface have the following meanings: V_F: The registration type is fingerprint V_P: The registration type is password

A unique ID number per user is required for enrollment. For each ID number you can enroll up to 10 fingerprints and 1 password. When the terminal is powered up, the interface looks similar to below:

Welcome 9:00 AM 04/28/06

FRI

2. When viewing admin records, the initials on the interface have the following meanings: E_U: General User Registration E_M: Administrator Registration E_DF: Delete Fingerprint Registration Record E_DP: Delete Password Registration Record D_L: Delete All Record Data S_T: Time Setting S_S: System Setting S_L: Record Setting S_C: Communication Setting

With the terminal powered on, please follow the detailed instructions below to enroll an employee’s fingerprint:

7.2 Setup

Select the Menu option; once that is displayed you will see the following image, and then select Data Management.

Press MENU to enter and select Setup menu. Then press OK to access the level-2 menu with the following display:

Menu Data Management Setup System Info Press OK to display the following:

Setup Record Setting Communication Display Adjust

Setup System Record Communication

The Setup menu consists of System Setting, Record Setting, Communication Setting and Display Adjustment Setting. 7.2.1 System Setting

Data Management User Admin Sensitivity

16 timeQplus BIOMETRIC™ Terminal User Manual

In System Setting, press OK to display the following:

System Admin Max Language Time

5 ENG

System Voice Out Unlock Auto Off timeQplus BIOMETRIC™ Terminal User Manual

Yes Yes No

29

Page 30

There are a total of six level-3 menus in the System Setting: Total Number of Administrators, Language, Time Setting, Voice Out, Unlock and Auto Shutdown, defaulted as below:

The correct finger positioning method is illustrated below, front and side view.

1. Total Number of Administrators Setup Value

Explanation

1-10

Set the total number of the administrators for the terminal

Factory Setting

5

2. Language Setup Value

Explanation

ENG

Content of the interface is displayed in English

Factory Setting

English

Correct

3. Time Setting Setup Value

Explanation

Time

Time setting for the terminal.

Factory Setting

Time setting of the terminal is consistent to the settings of the PC. It can also be set up using the PC software.

Not flat

Tilted

Off center

Too Low

4. Voice Out Setup Value

Explanation

Yes/No

Set the voice out option

Factory Setting

Yes

30 timeQplus BIOMETRIC™ Terminal User Manual timeQplus BIOMETRIC™ Terminal User Manual

15

Page 31

Chapter Five: Fingerprint Registration/Enrollment

5. Unlock*

When the TQ100 terminal and AttendanceRx software installation is complete, fingerprints will first be enrolled and then validated. For a network installation with multiple terminals a user’s enrollment is only needed on one terminal. Any timeQplus administrator can enable the enrolled user to use any terminal in the network.

Setup Value

Explanation

Yes/No

Set the door lock option

Factory Setting

No

*Note: this function is not supported in the AttendanceRx software.

5.1 Enrollment Method

6. Auto Off

Correct enrollment method: One or multiple fingerprints can be enrolled for every employee. It is recommended to use the index finger and/or middle finger for enrollment. Position your finger in the middle of the sensor. Apply light pressure.

Setup Value

Explanation

1-255

Set the Auto shutdown option

Factory Setting

No

Tips for improving the quality of fingerprint read: Dirty or Dry Finger

How to choose your finger

Incorrect positioning

Clean your finger with a moisturized soap; Wipe your finger with a pre- moisturized tissue (alcohol-free wipes, preferably enriched to hydrate the skin) Use the index or middle finger to enroll; try left hand fingers if the right hand (index or middle finger) fingerprints are faded, worn or missing. Place your finger in the middle on the sensor; keep you finger flat on the sensor and apply pressure trying to cover as much of the sensor window as possible; DO NOT touch the sensor in an angled or tilted position, DO NOT slide your finger.

7.2.2 Record Setting Select Record Setting menu, press OK to enter the level-3 menu as follows:

Record ARecAlert PRecAlert DupPunches

100 1000 No

There are three level-3 menus in Record Setting: Administrator Record Alert, Total Punches Record Alert and Punch Interval setting, defaulted as per below: 1. Admin Record Alert

Setting Items

Explanation

No

The terminal will not give out an alert when the admin records have overflowed. If the admin records surpass the maximum storage capacity, then the terminal will not store any new admin records. The maximum storage capacity for administrator records is 1000.

Fingerprint image changes

Re-enroll your finger if your fingerprint changes as a result of an injury, etc.

Fingerprint difficult to read

Use one (1:1) identification method. Key in your PIN number and place your finger on the sensor.

1 - 255

The terminal will give out alert according to the value set to inform the overflow of management records. If the value is 100, then the alert will be given out from the 900th record.

Other reasons

Use password registration as backup for people with hard to read fingerprints.

Factory Setting

100

14 timeQplus BIOMETRIC™ Terminal User Manual

Note: The user is prompted through the message on the display that the management record space is reaching the maximum capacity. timeQplus BIOMETRIC™ Terminal User Manual

31

Page 32

2. Total Punches Alert

Setting Items

Explanation

No

Indicates that the terminal will not give out alert when punches stored on the terminal are overflowed. If the total punches surpass the maximum storage capacity, then the terminal will not store any new punches. The maximum storage capacity is 30,000 punches.

1 - 1500

The terminal will inform that the records are overflowed according to the value set. If the value is 1000, then the alert will be given out from the 29,000th record.

Factory Setting

1000

4.2.3 Network Connection using Ethernet communication function with RJ45 interface

Note: The user is prompted through the message on the display that the punch storage space is reaching maximum capacity. Once the alert is given out, download the records as soon as possible.

3. Punch Interval (duplicate punches)

Setting Items

Explanation

No

Indicates the terminal will record all punches, including duplicate punches.

1 - 255

Indicates the terminal will disregard duplicate punches for subsequent punches received within the period of time that has been set up. The unit of measure is one minute.

Factory Setting

No

Note: If the user punches the terminal repeatedly within the set up interval defined, no duplicate records will be stored.

32 timeQplus BIOMETRIC™ Terminal User Manual

A) In Communication Setting, press Scroll-down to set RS485 communication to “No” and set Ethernet to “Yes”, displayed as follows:

Communication Default gateway RS485 Ethernet

No Yes

Note: A 6 ft Ethernet cable is included in the standard package.

B) Set the IP address, subnet mask and default gateway to those of the LAN. The IP address must be unique. The same password must be used both in the terminal setup and PC software. C) Turn the terminal off. D) Connect the network cable of the LAN to the RJ45 interface of the terminal. E) Turn on the terminal.

timeQplus BIOMETRIC™ Terminal User Manual

13

Page 33

4.2.2 RS485 network connection using RJ45 interface

7.2.3 Communication Setting Select Communication Setting menu and press OK to access the level-3 menu displayed as follows:

The TQ100 terminal can be connected using RS485. [Please Note: Due to the low demand for this type of connection, the RS232/ RS485 converter is not included in the standard package. See the Appendix at the end of this manual for details of the installation and setup of the RS485 configuration].

Communication Device ID Baud Rate Port No

1 38400 5005

Communication Setting Subnet mask Default gateway RS485 Communication Ethernet

Communication Password IP Address Subnet Mask

0

1 No Yes

There are nine level-3 options available for System Setting: Device ID, Baud Rate, Port Number, Password, IP Address, Subnet Mask, Default Gateway, RS485 and Ethernet connections. 1. Device ID (machine number)

A) In Communication Setting, press Scroll-down button and set RS485 communication to “Yes” and Ethernet to “No,” displayed as follows:

Communication Setting Device ID 1 38400 Baud Rate Port No 80

Note: Device ID number and Baud Rate should be consistent to the PC settings. RS232/ RS485 converter is not included in standard configuration.

B) Turn the terminal off. C) Connect the CAT5 Ethernet cable supplied in the package to the RS485/RS232 converter (Please refer to Appendix 8.2 for definition of cables, connectors and wire connections). D) Connect RS485/RS232 converter to the serial port of the PC and the other end to the RJ45 interface of the terminal. E) Restart the terminal.

Setting Items

Explanation

1 - 255

To set the ID number for machines.

Factory Setting

1

Note: Machine number is the unique ID for each machine. If there are two machines with the same machine number in the network, they will not work properly and the PC software will be confused when polling the terminals. Unique ID numbers need to be allocated for network use.

2. Baud Rate

Setting Items

Explanation

9600

The Baud Rate of Communication Port is set to 9600bps

19200

The Baud Rate of Communication Port is set to 19200bps

38400 (default)

The Baud Rate of Communication Port is set to 38400bps

Factory Setting

38400

Note: The value must be set consistent with the communication ports of the PC Administration Machine. No communication can be achieved otherwise.

12 timeQplus BIOMETRIC™ Terminal User Manual timeQplus BIOMETRIC™ Terminal User Manual

33

Page 34

3. Port Number

Setting Items

Explanation

1 - 9999

To set the software port of the Ethernet communication of the terminal.

Factory Setting

5005

4.2.1 Direct Connection using RS232 with RS232 communications

Note: The port number must be consistent to port number of the software in the PC administration machine. No communication can be made otherwise.

4. Password

Setting Items

Explanation

0 - 999999

Set the access password of Ethernet communication

Factory Setting

No

A) In Communication Setting, press Scroll-down button. The default display is as follows: Note: RS232 is used to directly

5. IP Address connect one terminal per

Setting Items

Explanation

192.168.1.224

Set the IP address of the machine when access through Ethernet communication.

Factory Setting

192.168.1.224

Note: The IP address in the LAN must be unique.

6. Subnet Mask

Setting Items

Explanation

255.255.255.0

Set the subnet mask of the LAN when using Ethernet communication.

Factory Setting

255.255.255.0

Communication Settings Device ID 1 Baud Ratio 38400 Port No 80 computer. In this case, default setting is recommended. For network configurations using multiple terminals, the device ID number must not be repeated and must be set to different numbers.

B) Turn off the TQ100 terminal. C) Turn off your PC. D) Using the thirty foot (9 m) RS232 serial cable included in your package connect one end to your PC communication serial port and the other end to TQ100 terminal. E) Power on the PC, then the terminal.

Note: Subnet mask must be consistent to the LAN IP address of the device.

34 timeQplus BIOMETRIC™ Terminal User Manual timeQplus BIOMETRIC™ Terminal User Manual

11

Page 35

Chapter Four: Communications 4.1 Communication Interfaces There are two communication interfaces available for the TQ100 terminal: 9-pin RS232 interface and RJ45 interface, as illustrated in the Figure 4.1. The RS232 interface provides RS232 communication, while the RJ45 interface provides RS485 and Ethernet communication, see Figure 4.1 below.

7. Default Gateway

Setting Items

Explanation

192.168.1.1

Set the default gateway of the LAN when using the Ethernet communication.

Factory Setting

192.168.1.1

Note: The default gateway must be consistent to the LAN settings.

8. RS485 Communication Figure 4.1 RJ45 Interface

RS232 Interface

Attention: 1. Maximum communication distance of RS232 cable is 50 feet (15 m). 2. RS485 communication can connect multiple terminals (up to 32 terminals) and the maximum communication distance can reach 1000 feet (300 m). For optimal performance it is recommended to use up to 10 terminals in a RS485 network installation. 3. Ethernet communication mode belongs to Ethernet network connection. It can be used to connect any terminals in the LAN.

4.2 Communication Options

Setting Items

Explanation

Yes

Make the RS485 communication available.

Factory Setting

No

9. Ethernet

Setting Items

Explanation

Yes

Make the Ethernet communication available.

Factory Setting

Yes

Choose from three communication options: 1. Direct Connection using RS232 with RS232 communications. 2. RS485 network connection using RJ45 interface 3. Network Connection using Ethernet communication function with RJ45 interface.

10 timeQplus BIOMETRIC™ Terminal User Manual timeQplus BIOMETRIC™ Terminal User Manual

35

Page 36

7.2.4 Display Adjustment Setting

3.3 System Info

Select Setup menu and press OK to display the following:

With System Information highlighted, press OK to access System Information level-2 menus. You will see three menu items displayed. Press OK in each menu to display the corresponding item as follows:

Setup System Record Communication Display Adjust

Level-1 Menu

Level-2 Menu

Select Display Adjust and press OK. A “click” sound will be produced indicating that the brightness auto match function of the sampling instrument in the machine is complete. The software will search for the optimal brightness value for the display.

User (# of users)

7.3 System Info Select System Information menu and press OK to access the level-3 menu as follows:

Fingerprint Registration

System Info User Finger Punches

5 5 10

System Info Admin Password Admin Recs

Level-2 Menu Press OK

Administrator (# of Administrators)

Press OK

Password

System Info

1 0 7

There are 6 level-3 menus in System Information, namely User registration, Administrator registration, Fingerprint registration, Password registration, total Punches and Administrator Records. These items can be alternated using the OK button.

Total (# Punches)

Press OK

Admin Recs (# Admin Recs)

Note: When User is selected, pressing OK switches between User and Admin. The other items work in a similar way.

1) User Registration: to view the total number of users registered. 2) Administrator Registration: to view the total number of administrators registered. 3) Fingerprint Registration: to view the total number of fingerprints registered. 4) Password Registration: to view the total number of passwords registered. 5) Total Punches: to view the total number of punches recorded. 6) Administrator records: to view the total number of admin records.

36 timeQplus BIOMETRIC™ Terminal User Manual timeQplus BIOMETRIC™ Terminal User Manual

9