The text of a manual · part 1 of 5
timeQplus BIOMETRIC Terminal User Manual (TQ100 Terminal User Manual), pages 1 to 9
Pages 1 to 9 of 44
The original document is the PDF (881 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Acroprint TQ100
Page 1
FIREWALL INFORMATION Attention Microsoft Windows XP and Windows 2003 Users! Microsoft Windows Firewall: Microsoft has included firewall protection on Windows XP with Service Pack 2 and on Windows 2003 Server with Service Pack 1. If you will be installing your timeQplus BIOMETRIC server on either of these two operating systems you will need to grant access on the firewall to the following applications and services after your installation is complete.
BIOMETRIC FINGERPRINT TECHNOLOGY
• Attendance Rx Note: You will be prompted to unblock this application after the installation is complete, or you can grant access via the firewall. • arxsvc.exe • ARXTQ100N.exe • File and Printer Sharing
Other Firewalls:
Some firewalls block ports, and authorized applications can be granted access to use specific ports. If you have this type of firewall you should open the following ports: • TCP • UDP
Open ports 49183 to 49188 Open ports 49211 to 49212
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna; Increase the separation between the equipment and receiver; Connect the equipment into an outlet on a circuit different from that to which the receiver is connected; Consult the dealer or an experienced radio/TV technician for help. PN: 06-0349-000 Rev C.
44 timeQplus BIOMETRIC™ Terminal User Manual
TQ100 Terminal User Manual
Page 2
2 timeQplus BIOMETRIC™ Terminal User Manual timeQplus BIOMETRIC™ Terminal User Manual
43
Page 3
Product Reference Guide Additional terminals, product upgrades and cables are available. Please contact Acroprint at 1.800.334.7190 to order today.
Part Number: 01-0229-000 TQ100 terminal
Chapter One: Introduction 1.1 1.2 1.3
Operating Environment………………………..…..... 4 System Description ……………………………......... 4 Enclosed Items …………………………………........ 4
Part Number: 01-0229-001 TQ100b - Terminal with operational back-up battery
Chapter Two: Hardware Setup
Part Number: 08-0140-086 25 employee user upgrade
Chapter Three: Menu Structure
Part Number: 87-0106-000 FIU optical overlay Part Number: 72-0203-000 485 cable for timeQplus Biometric (6 ft) Part Number: 25-0134-000 485/232 Converter assembly (RJ11/9 PIN)
2.1 2.2 3.1 3.2 3.3
Terminal Installation ………………………………...... 5 Keyboard ……………………………………………....... 5 Data Management………………………………......… 7 Setup…………………………………………………........ 8 System Info …………………………………………...... 9
Chapter Four: Communications 4.1 4.2 4.2.1 4.2.2 4.2.3
Communication Interfaces ……………………….... 10 Communication Options…………………………….... 10 RS232 Serial Communication……………............ 11 RS485 Network Communication……......…........ 12 Ethernet Communication…………………............. 13
Chapter Five: Fingerprint Registration/Enrollment 5.1 5.2
Enrollment Method………………………..…........... 14 Fingerprint Registration……………………............ 16
Chapter Six: Terminal Usage and Punching In/Out 6.1 6.2
Successful validation when punching In/Out..... 20 Unsuccessful validation when punching In/Out.. 21
Chapter Seven: Administrator Functions 7.1 7.2 7.3
Data Management……………………………........... 23 Setup………………………………………………........... 29 System Info ……………………………………........... 36
Chapter Eight: Appendix 8.1 8.2
42 timeQplus BIOMETRIC™ Terminal User Manual
RS232 Interface ………………………………........... 37 RJ45 Interface…………………………..……............ 38 timeQplus BIOMETRIC™ Terminal User Manual
3
Page 4
Chapter One: Introduction Thank you for your recent purchase of the TQ100, a data collection terminal for timeQplus BIOMETRIC™ time and attendance system. This user manual provides specific information that will help you better understand the functionality of the terminal (TQ100). Some key areas that are important to the terminal’s (TQ100) performance are the operating environment, the system overview, communication options and enrollment.
Ethernet Communication Diagram
1.1 Operating Environment Please read the manual carefully before using the product. The terminal operates most efficiently by following these recommendations: 1. DO NOT expose the TQ100 to direct sun light. Direct sunlight may impact the fingerprint reader optics and affect enrollment, quality of the templates, and performance of the fingerprint recognition process. 2. TQ100 operating temperature is 39F-110F. Do not operate the terminal outdoors. High temperature and humidity may affect its performance.
1.2 System Description The timeQplus BIOMETRIC™ time and attendance system consists of two parts: 1. Fingerprint terminal TQ100 2. AttendanceRx, the time and attendance management software that runs on the PC. The TQ100 terminal’s main function is to register employees’ fingerprints and record daily time and attendance. The PC software is used to manage the TQ100 and process employee information using a set of attendance rules defined by the Administrator. The PC software interacts with the terminal TQ100, calculates time, and generates reports. The time and attendance PC software application compatible with the TQ100 is called AttendanceRx. Three communication options are available between the TQ100 terminal and the PC software: serial (RS232) and network (RS485, Ethernet).
1.3 Enclosed Items 1. Quick Start timeQplus BIOMETRIC installation guide 2. Time and attendance software CD, AttendanceRx 3. TQ100 biometric terminal 4. Hardware user manual for the TQ100 5. Serial RS232 cable, 30 feet (9 m) 6. CAT5 Ethernet cable, 6 feet (2 m) 7. Power adapter 8. Mounting plate and screws
4 timeQplus BIOMETRIC™ Terminal User Manual timeQplus BIOMETRIC™ Terminal User Manual
41
Page 5
Chapter Two: Hardware Setup
RS485 Wiring Diagram
2.1 Terminal Installation To power up the TQ100 biometric terminal: A) Unwrap the package and take out the terminal and accessories. B) Using the screws supplied, fasten the mounting plate on the wall in an appropriate place. Avoid areas with strong magnetic and/or electric fields. C) Attach the terminal to the mounting plate. D) Plug in the power supply and turn the terminal on (Press button).
2.2 Keyboard image and functions Junction Box Terminal 2
PC
Junction Box Terminal 1
To Terminals 3 - 32
Keypad configuration is presented in Figure 2.1:
Teflon Cable
Junction Box
To Terminal 2
To Terminal 1 (short as possible)
2
3
ESC
4
5
6
▲
7
8
9
▼
•
0
OK
MENU
RJ11 Cable
RS232/RS485 Converter
Attach an RJ11 connector to the Cat5 cable terminated with an RJ45 connector and supplied with the standard package. Looking at the RJ11 connector pictured above the Brown wire goes to the leftmost PIN and the Brown/White wire goes to the rightmost PIN.
1
Figure 2.1 To serial port on host computer
The keypad functionality is described below ESC
To perform EXIT, CANCEL, IGNORE when using the menu
MENU
To access the Menu structure
OK
To confirm and save the selection Power switch Scroll-up button for menu operations Scroll-down button for menu operations
0-9
Keys to use when operating or performing system setup or entering User ID or password
40 timeQplus BIOMETRIC™ Terminal User Manual timeQplus BIOMETRIC™ Terminal User Manual
5
Page 6
Chapter Three: TQ100 Biometric Terminal Menu Structure The terminal uses function and number keys to navigate through the menu options and to access system settings. Level-1 menus include: Data management, Settings and System Information. Each menu consists of subordinate level-2 menus such as User Registration and View Punches. Level-3 menu include enrollment method selection, sensitivity settings, etc.
RS485 Connection For the RS485 communication, TQ100 only uses two wires in the cable, the Brown (8) and the Brown/White (7). The RS485 communication setup requires the following steps: 1.
Take the CAT5 Ethernet cable supplied in the box and cut one end, exposing the wires.
2.
Attach an RJ11 connector to the bare end of the cable; looking at the RJ11 connector (see the RS485 wiring diagram below) the Brown wire goes to the leftmost pin. The Brown/White wire goes to the rightmost pin of the RJ11 connector.
3.
Connect the cable above one end at the RJ45 Interface of terminal and the RJ11 connector to a Junction Box; the Black wire in the Junction Box should go to the Brown (8) wire in the CAT5 cable, and the Yellow wire in the Junction Box should go to the Brown/White (7) wire.
4.
Connect the last Junction Box to a RS485/RS232 converter using a standard phone cable.
5.
Connect the RS232 interface to the PC.
Menu structure contains: a. Data Management: to setup, change or delete data (e.g. enroll fingerprints, passwords, administrators, delete records, track attendance); to perform audits for system changes and set up sensitivity levels for the fingerprint reader. b. Setup: to set up the TQ100 to communicate with the PC software application. c. System Information: to examine the information recorded in the terminal and view statistical data. The structural diagram of the menu is illustrated as follows:
Data Management Menu
RS485 Communication Design
Setup System Information
Level 1
6 timeQplus BIOMETRIC™ Terminal User Manual timeQplus BIOMETRIC™ Terminal User Manual
39
Page 7
8.2 RJ45 Interface
3.1 Data Management
The RJ45 interface provides RS485 and Ethernet communication.
With Data Management option highlighted, press OK to access Data Management level-2 menu and browse through the seven items available. Some of the items have corresponding sub-items, the level-3 menu, as shown below:
Level-1 Menu
Level-2 Menu
Level-3 Menu
User Registration
Fingerprint Password
Administrator Registration
Sensitivity
The wiring diagram of the supplied RJ45 connection cable is as follows:
PIN
Definition
1
TCP_TX+
2
TCP_TX-
3
TCP_RX+
Fingerprint or Password
Data Management
Sensitivity Level Setting
User Setting
Global Setting Delete Registration Data
4 5 6
TCP_RX-
7
RS485A
8
RS485B
View Punches
View Admin Record
Delete All Records
38 timeQplus BIOMETRIC™ Terminal User Manual timeQplus BIOMETRIC™ Terminal User Manual
7
Page 8
3.2 Setup
Chapter Eight: Appendix
With Setup highlighted, press OK to access the Setup level-2 menus and browse the four items available. There are a total of 18 level-3 menus as per the diagram below. For more information on each menu, please refer to page 26.
Two types of interfaces are available in the terminal: 9-pin RS232 interface (for direct RS232 serial communication) and an RJ45 interface (for RS485 and TCP/IP over Ethernet communications).
Level-1 Menu
Level-2 Menu
Level-3 Menu Admin max number
Language
PIN
Definition
1
Reserved
Date Format
2
RS232 TX
AM/PM
3
RS232 RX
4
LOCK Data 1
5
GND
Unlock
6
Reserved
Auto Shutdown
7
Data ()
Card*
8
Reserved
9
Reserved
Admin Record Setup
Record Setting
The RS232 interface (refer to page 10 figure 4.1) provides RS232 communication, Lock and Wiegand entrance guide function with 9 pins in total. Definitions of each pin are listed in the following table:
Time
Voice Out System Setting
8.1 RS232 Interface
Total Punches Alert Duplicate Punches Device ID
Note: For door access and/or access control applications: connect with the pins four and five when using the simple entrance guard; white connect pins four five and seven when adopting Wiegand output.
A typical RS232 connections diagram looks like the figure below:
Baud rate Port number Communication Setting
RS232 Communication Diagram
Password IP Address Subnet Mask
Display Adjustment
Default RS485 Ethernet
*The card option is not available on standard units.
8 timeQplus BIOMETRIC™ Terminal User Manual timeQplus BIOMETRIC™ Terminal User Manual
37
Page 9
7.2.4 Display Adjustment Setting
3.3 System Info
Select Setup menu and press OK to display the following:
With System Information highlighted, press OK to access System Information level-2 menus. You will see three menu items displayed. Press OK in each menu to display the corresponding item as follows:
Setup System Record Communication Display Adjust
Level-1 Menu
Level-2 Menu
Select Display Adjust and press OK. A “click” sound will be produced indicating that the brightness auto match function of the sampling instrument in the machine is complete. The software will search for the optimal brightness value for the display.
User (# of users)
7.3 System Info Select System Information menu and press OK to access the level-3 menu as follows:
Fingerprint Registration
System Info User Finger Punches
5 5 10
System Info Admin Password Admin Recs
Level-2 Menu Press OK
Administrator (# of Administrators)
Press OK
Password
System Info
1 0 7
There are 6 level-3 menus in System Information, namely User registration, Administrator registration, Fingerprint registration, Password registration, total Punches and Administrator Records. These items can be alternated using the OK button.
Total (# Punches)
Press OK
Admin Recs (# Admin Recs)
Note: When User is selected, pressing OK switches between User and Admin. The other items work in a similar way.
1) User Registration: to view the total number of users registered. 2) Administrator Registration: to view the total number of administrators registered. 3) Fingerprint Registration: to view the total number of fingerprints registered. 4) Password Registration: to view the total number of passwords registered. 5) Total Punches: to view the total number of punches recorded. 6) Administrator records: to view the total number of admin records.
36 timeQplus BIOMETRIC™ Terminal User Manual timeQplus BIOMETRIC™ Terminal User Manual
9