For the Accu-Time Series 3000

Page 11

ACCU-RATE SET-UP AND DIAGNOSTICS

POWER UP To power up the Series 3000 a 12VDC source must be applied to the terminal power jack. The Series 3000, with the TEST/USE switch placed in the USE mode, beeps, executes a power up sequence and displays the message “TERMINAL LOCKED”. ACCESSING TEST MODE To access the test mode: 1)

Unlock the base assembly on the Series 3000.

2)

Locate the Test/Use switch on the back of the terminal.

3)

Slide the switch into the TEST position (away from the modular jacks). The Series 3000 displays “ATS TEST MODE”.

4)

By pressing the CLEAR key, the user can step through the selections. (*NOTE* Test mode may be exited at any time by placing the Test/Use switch back to the USE position and pressing the CLEAR key).

SELECTIONS: •

ATS TEST MODE: Tests the Keypad, Display, Memory, Real Time Clock, Bar Code or Magnetic Slot reader and Bar Code Wand.

•

ATS SET-UP MODE: Configures the communication parameters - Baud Rate, Parity Bit, Terminal Address, and Terminal Application Type.

•

ATS NETWORK TEST: Performs a terminal to host communication loop-back test. Verifies integrity of cabling.

•

ATS BATTERY TEST: Checks the terminal battery backup option.

•

ATS DI-DO TEST: Checks the Digital Input/Digital Output auxiliary port by performing a loop-back test.

•

ATS RESTART MODE: Resets the terminal, clears all data from memory and performs a power-up sequence.

MANU3000-01(01)

8

Page 12

ATS TEST MODE: ATS TEST MODE checks the functionality of the terminal Keypad, Memory, Real Time Clock, Bar Code or Magnetic Slot reader and Bar Code Wand. To enter the TEST MODE, press the ENTER key. The message “ATS TEST MODE” appears on the top line of the nd display. The 2 line of the display indicates the program (EPROM) number. By pressing the ENTER key the following information appears: ATS TEST MODE (XXX) (YY) -------------------------The terminal displays “ATS TEST MODE” on the top line followed by two sets of numbers. The first number (XXX) indicates the amount of memory installed (in Kilobytes). The right most number (YY) indicates the terminal Real Time Clock incrementing in seconds (00-59). Testing the Keypad At this time the user may test the keypad assembly. Each time a key is pressed the terminal will beep and the key nd value will appear on the 2 line of the display. Press the ENTER key. The message “KEY INPUT ACCEPTED” is displayed. Each time the ENTER key is pressed an internal test of the terminal’s communication port is performed. If an error is detected the message “COMM PORT FAIL” will display, the invalid light will flash and the negative acknowledgement beeper tone will cycle. This message will continue until power is removed from the terminal. Testing the Badge Reader ATS TEST MODE accepts inputs from slot readers (optical or magnetic) and bar code wands. To test the reader, simply swipe the applicable bar code or magnetic stripe badge. The terminal beeps and displays the badge data. To test the bar code wand, the user lightly drags the tip of the wand across the entire bar code badge or label. The wand should be positioned in the hand (similar to that of a pen or pencil) at approximately a 30ο angle. Begin the scanning process by dragging the wand horizontally, in a straight line, and at a constant speed across the entire label area. Each bar code label includes a preceding and trailing ¼ inch quiet zone. This area which is free of any marks or bars is a part of the bar code label and must be included when scanning the label. Upon the successful completion of a bar code read, the terminal will beep and display the data. To proceed to the ATS SETUP MODE press the CLEAR key. ATS SETUP MODE ATS SETUP MODE allows the operator to configure the terminal for communications with the host computer. The Series 3000 default parameters are set as follows: Baud Rate Parity Address Terminal Application Type

9600 ODD 01 A

To enter the ATS SETUP MODE, press the ENTER key at the “ATS SETUP MODE” display prompt. (Prior to nd pressing the ENTER key the 2 line of the display will indicate the current terminal setup values)

MANU3000-01(01)

9

Page 13

Baud Rate To change the terminal baud rate: 1. Press the CLEAR key to step through the baud rate choices: 19200 9600 4800 2400 1200 M1200 (modem) M2400 (modem) 2.

When the desired baud rate is displayed, press the ENTER key to store the value and advance to the next parameter.

3.

If a modem baud rate is selected, a self-test will be performed on the modem. The results of this test will be displayed. The operator will be prompted to enter the number of auto answer rings. NOTE: If no modem is installed and a modem baud rate has been selected, the modem self test will fail.

Parity To change the parity: 1.

Press the CLEAR key to step through the parity choices: ODD EVEN NONE

2. When the desired parity is displayed, press the ENTER key to store the value and advance to the next parameter. Address To change the terminal address: 1.

Press the CLEAR key to increment the address values from 01 to 32.

2.

When the desired address is displayed, press the ENTER key to store the value and advance to the next parameter.

Terminal Application Type The Terminal Application Type is used as a delimiter by the host for routing application information to the terminal. (Example-an access control terminal could have a different terminal type than a time and attendance terminal) To change the terminal application type: 1.

Press the CLEAR key to increment the type from A to J.

2.

When the desired type is displayed, press the ENTER key to store the value and advance to the ATS NETWORK TEST.

MANU3000-01(01)

10

Page 14

ATS NETWORK TEST ATS NETWORK TEST is a two-part test. The first allows the network wiring between the terminal and the host to be checked for open connections or wiring errors. This test requires that the ATS RS232 Communication Adapter which is plugged into the host, be unplugged and pins 2 & 3 of the adapter jumped together (a paper clip should do the trick). Secondly, a local test can be performed on the terminal communication circuitry. This test will work for both RS232 and RS485 installations (RS485 installations require an ATS 232/485 Converter). To enter NETWORK TEST, press the ENTER key at the “ATS NETWORK TEST” prompt. The following message appears: SWITCH TEST SWITCH TO USE POSITON Place the switch on the back of the terminal into the USE position. The Series 3000 performs a network test in which the terminal sends data up to the host, via the network cabling. Since a temporary jumper was installed in the ATS RS232 Communication Adapter, the data will be looped back to the terminal. The following message should appear: NETWORK TEST PASS ENTER TO RETEST To perform the local communication loop back, place the USE/TEST switch back to the TEST position and press the ENTER key. The following message should appear: NETWORK TEST PASS ENTER TO RETEST Remove the jumper from the RS232 Communication Adapter and secure it back into the host port. Press the CLEAR key to advance to the next test.

ATS BATTERY TEST: The ATS BATTERY TEST checks the terminal battery backup option if installed. To enter this test, press the ENTER key at the “ATS BATTERY TEST” prompt. The following message should appear: BATTERY TEST PASS ENTER TO RETEST Note: If the battery backup option is not installed, the battery test will fail. Press the CLEAR key to advance to the ATS DI-DO Test.

ATS DI-DO TEST The ATS DI-DO Test is a two-part test that checks the terminal auxiliary DATA IN/DATA OUT port connection by performing a loop back communication test on the port circuitry. To enter the ATS DI-DO Test: 1.

Press the ENTER key at the “ATS DI-DO TEST” prompt. The following message should appear: SWITCH TEST SWITCH TO USE POSITION

2.

Place the test switch into the USE position. Since no loop back jumper is installed during this phase of testing the following message will appear:

MANU3000-01(01)

11

Page 15

DI-DO TESTING DI-DO TEST FAILED ENTER TO RETEST 3.

Place the TEST/USE switch into the TEST position. This will provide the terminal with its own loop back jumper.

4.

Press the ENTER key. The following message should appear: DI-DO TEST PASSED ENTER TO RETEST

5.

Press the CLEAR key to advance to ATS RESTART MODE.

ATS RESTART MODE The ATS RESTART MODE clears all transaction data and any download from memory. To restart the terminal: 1.

Press the ENTER key to select the ATS RESTART MODE. The terminal displays: PRESS ENTER TO CLEAR ALL TRANSACTION DATA

2.

Press the ENTER key. The terminal displays: CLEAR FOR CYCLE TEST (Note: Cycle test is for factory diagnostics only) ENTER FOR RESTART

3.

Press the ENTER key. The terminal displays: CLEARING MEMORY. . . The green Valid LED will blink and the terminal will execute its power up sequence and return the terminal back to the beginning of the Test Mode.

4.

To exit the Test Mode, place the TEST/USE switch to the USE position and press the CLEAR key. The terminal will execute its power up sequence. The terminal displays: “TERMINAL LOCKED” The terminal can now accept a host download. This completes the ACCU-RATE test and set-up

Downloading the Series 3000 The Series 3000 terminal, when used with a standard Time and Attendance "C" application, can be downloaded with employee names, badge numbers, schedules, etc. These download commands and others are explained in the Time and Attendance Labor Tracker command set manual. For further information refer to this manual.

MANU3000-01(01)

12

Page 16

MAINTENANCE

The Series 3000 is a maintenance-free data collection device. The only required procedure is periodic cleaning of the badge reader. To clean the badge reader, swipe a pre-moistened (isopropyl alcohol) cleaning card through the reader several times. Low usage readers should be cleaned monthly. High usage readers should be cleaned weekly.

MANU3000-01(01)

13

Page 17

TROUBLESHOOTING GUIDE

Problem: Terminal does not power up and none of the status LEDs are lit. Possible cause: No DC power applied Solution: Ensure primary side of DC power pack assembly is plugged into a live AC outlet. Ensure secondary side of DC power pack assembly is plugged into the Time and Data Collection Terminal (DCT). Problem: Terminal display is blank (no character or backlight). Possible cause: The primary of the power pack assembly is not plugged into a 110VAC-wall outlet. Solution: Test the outlet by plugging in another appliance or check that the secondary supply is plugged into the terminal. Solution: If all else fails, replace the power pack assembly. NOTE: The terminal will operate for approximately 4-hours with battery power when primary voltage source is lost. After this, the terminal will power off. The yellow indicator light, located on the front of the terminal, will illuminate prior to the terminal blanking out. Problem: Yellow Low Power indicator is lit. Possible cause: Low DC power is attached. Solution: Replace 12-volt DC power pack. Possible cause: Terminal does not go blank after unplugging the battery connector. Solution: Unplug and replace the power pack assembly. Problem: Terminal is not communicating with Host. Possible cause: HOST TEST/USE switch is in the TEST position Solution: Place the HOST TEST/USE switch is in the USE position. Possible cause: DCT to Host communication cable is defective or unplugged on either end. Solution: Verify cable is tested and plugged into both ends. (Ensure cable termination guidelines and lengths are observed.) Solution: Ensure the application package is loaded and running on the host. Possible cause: Communication parameters for the DCT do not match those of the Host. Solution: Refer to the ACCU-RATE test and diagnostics section for set-up directions. Problem: DCT does not accept badge data. Possible cause: Bar code badge is not manufactured to proper specification.

MANU3000-01(01)

14

Page 18

Solution: Refer to vendor’s specifications for manufacturing criteria. Possible cause: Badge is being swiped in the wrong direction. Solution: Ensure media faces to the right (away from the keypad). Possible cause: Badge reader needs cleaning. Solution: Swipe a pre-moistened (isopropyl alcohol) cleaning card through the reader several times. Possible cause: Badge number does not exist in validation file. Solution: See Supervisor Note: If all solutions fail try reading badge in the ACCU-RATE test mode. Problem: Terminal does not accept keypad input. Possible cause: Keyed data does not exist in validation file Solution: See Supervisor Possible cause: Keypad connector is unplugged. Solution: Test keypad in the ACCU-RATE test mode. If all solutions have been explored and the problem still exists, contact the Accu-Time Product Service Department at (860) 870-5000 during normal working hours 9 AM to 5 PM- Monday through Friday. Prior to contacting AccuTime, please have available the serial number and if possible the configuration number of the product. NOTE: The DCT has no user serviceable parts. The Accu-Time terminal must be operated within the parameters included in this manual. Any operation performed contrary to these parameters will void the warranty

MANU3000-01(01)

15

Page 19

FCC STATEMENT

This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: * * *

Reorient or relocate the receiving antenna. Increase the distance between the time clock and the receiver. Connect the equipment into an outlet on a circuit different from that which the receiver is connected.

FCC Warning: To assure continued FCC emission limit compliance, the user must use only the recommended shielded interfacing cable when connecting to a host computer. Also, any unauthorized changes or modifications to this equipment would void the user authority to operate this device.

MANU3000-01(01)

16

Page 20

3000 SERIES MOUNTING TEMPLATE 6" 3" "A"

"A" 4 3/4" 2 3/8"

"B" 2 3/8"

"B" "A"

• •

When securing to a flat wall, use the mounting-hole pattern, labeled “A”. When securing to a standard 4” electrical box, use the mounting-hole pattern labeled “B”.

MANU3000-01(01)