The text of a manual · part 1 of 2
Series 3000 Time and Data Collection Terminal, pages 1 to 10
Pages 1 to 10 of 20
The original document is the PDF (83 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Time Series 3000
Page 1
SERIES 3000 TIME AND DATA COLLECTION TERMINAL
Accu-Time Systems, Inc. 420 Somers Road, Ellington, CT 06029 Tel: (860) 870-5000 Fax: (860) 872-1511 Web Site: www.accu-time.com
Page 2
Copyright 1992 Accu-Time Systems, Inc., Third Printing, 1998. Accu-Time is a registered trademark of Accu-Time Systems, Inc. The material contained in this manual is subject to change. No part of this manual may be reproduced or distributed in any form or by any means, or stored in any database or retrieval system, without Accu-Time’s prior written permission. Accu-Time Systems, Inc. makes no warranty of any kind including, but not limited to, any implied warranties of merchantability, and fitness for a particular purpose in regard to this manual. All Rights Reserved. Printed in the USA.
Page 3
ACCU-TIME SERIES 3000
TABLE OF CONTENTS
Introduction
1
Features Specifications Installation
2 3 4
ACCU-RATE Diagnostics Maintenance Troubleshooting guide
8 13 14
MANU3000-01(01)
Page 4
INTRODUCTION The Accu-Time Series 3000 is the benchmark for full-function Data Collection Terminals. Open ACCU-TECTURE, “C” programmable and feature-rich packaged in an attractive almost indestructible die cast housing, the Series 3000 is ideally suited in small or large employee based companies. Among the many features of the Series 3000 are: •
Multi-Media: Can support most standard bar code formats including UPC, 128, 39, 2/5, I2/5 and more, as well as IATA Track I and ABA Track II magnetic stripe input.
•
Flexibility: The Series 3000 can act as a stand alone time station or as part of a local or wide area network. The terminal can also interface with virtually any host hardware or software platform.
•
Custom Applications: Custom programs and programmable function keys can provide users with the flexibility to create a variety of options.
•
Reliability: A Real Time Clock (RTC) provides 12 or 24 hour time formats with quartz precision. An optional non-interruptible power supply (UPS) provides terminal operation for up to 4 hours during power outages. Data storage will be preserved for up to 4 days with the memory backup system.
•
Durability: Environmental enclosure protects circuitry from environmental conditions such as extreme temperatures and airborne dust.
Versatility, Reliability and Affordability in a state-of-the-art ergonomically designed terminal and backed by the ACCUTEAM.
MANU3000-01(01)
1
Page 5
FEATURES
•
EIA Standard RS232 or RS485 compatible, 12/2400-Baud Modem operation
•
On-board ACCU-RATE terminal set-up and diagnostics package.
•
Custom keypad legends with software defined function keys
•
Large 20 key tactile 4x5 matrix keypad.
•
Dual tone audible enunciator
•
Single or multi-clock environments on a variety of host platforms with application programs integrating the ATS DATA TRAKER family of modules
•
64K Byte Memory base (capacitor backed) for buffered or interactive validation
•
Integrated and/or External Bar Code slot reader
•
Integrated Magnetic slot readers
•
Digital Bar Code Wand port
•
Touch Memory and RF ID support
•
Relay and Printer Interface modules
•
Low voltage power source locally or remotely supplied
•
Non-interruptible power source with on-board charger
•
Die cast aluminum housing with steel key-lockable base assembly
•
CE Mark and FCC part 15 Certified
MANU3000-01(01)
2
Page 6
SPECIFICATIONS
Display:
2 Line x 20 Character super-twist LCD (backlit option available) 4 Line x 20 Character super-twist LCD (backlit option available) 2 Line x 20 Character Vacuum Fluorescent
Clock:
12 or 24 hour-format-USA or International (quartz precision) Time stamp of data transactions
Indicators:
Yellow LED Low Power indicator. Two programmable LED indicators, RED and GREEN.
Memory:
64K Byte of capacitor backed memory (i.e.; 300-employee base-program dependent)
Programming:
ATS DATA TRAKER modules, “C” programming language or third party custom application packages.
Interface:
EIA Standard RS232 or RS485 (2 or 4 wire) Standard AT Command set for internal 12/2400-Baud Modem
Enclosure:
Die cast aluminum housing with steel key-lockable base assembly
Power:
+10 to +17VDC (+12VDC @ 250 milliamps Nominal). Local, remote or centrally powered Non-interruptible power source with charger (optional)
Environment:
Operation: 32° to 110° F (0° to 43° C)
Certification:
CE Mark Certified (CE, RE, ESD, RS and CS), FCC part 15
Physical:
7.25” wide x 7.0” high x 3.4” deep; weight 4 pounds
Accessories:
Integrated and/or External Optical Bar Code slot readers Integrated magnetic slot readers, RF ID technology, Digital Bar Code Wands External Wand emulation Bar Code Laser and CCD readers Auxiliary relay or Printer Interface port
MANU3000-01(01)
3
Page 7
INSTALLATION
GENERAL INSTALLATION GUIDELINES
Environment Although the Series 3000 Time and Data Collection Terminal is a durable industrial-grade device, which will endure harsh environments, it never the less is an electronic device. Environmental constraints exist and care should be given when selecting a location for installing and operating the Series 3000. The ATS terminal is designed to operate indoors. Exposure to outdoor elements such as rain or snow will not only void the manufacturer warranty, but may cause damage to the device. Select a location, which has adequate lighting and accessibility to operate the terminal safely.
Operating parameters Accu-Time recommends the Series 3000 be operated in an ambient temperature range of between 32° and 110° Fahrenheit. Non-condensing humidity should be less than 95%. The terminal should be mounted on a vibration free area. The RS232 Series 3000 must be located no greater than fifty (50) wire-feet from the host computer. EIA standards for RS232 protocol data transmission dictate this cable distance. Exceeding this requirement greatly increases the chances for continual data re-transmission, which may never be acknowledged. The RS485 Series 3000 locally powered must be located no greater than five thousand (5000) wire-feet from the host computer. EIA standards for RS485 protocol data transmission dictate this cable distance.
MANU3000-01(01)
4
Page 8
INSTALLATION Base Locate a flat wall surface to accommodate the Series 3000. With terminal power being supplied locally, insure that a conventional 110VAC-wall outlet, 220VAC in Europe and other areas, (check local electrical code requirements) is dedicated to accept the Series 3000 12VDC power pack assembly. The outlet should be no further than four (4) feet from the terminal. With the supplied terminal mounting template, prepare the wall to accommodate mounting hardware (customer provided). Typical mounting height is forty-eight inches from floor to the terminal display (Compliant to the Americans with Disabilities Act). Observe OSHA and/or local safety codes when operating tools during all phases of installation. Attach the terminal wall mount to the flat wall surface. Select and remove one of the perforated knockouts on the wall mount, which will accommodate the data transmission and 12VDC power pack cable assemblies. Data Cable For RS232 applications, ATS recommends using its modular telephone type data cable. This eight- (8) conductor shielded flat cable has RJ-45 modular plugs on each end. The fifty (50) foot cable, ATS part number (63-2003-02), may run along side base-moldings, walls, overheads, or in hostile environments through conduit tubing. One end of the cable terminates into the Series 3000 communication port while the other terminates into the host computer’s serial port via an ATS RS232 Communication Adapter.
RS232 INSTALLATION
12 VDC POWER SUPPLY
ACCU-TIME SYSTEMS ELLINGTON, CT
LOW
INVALID
VALID
POWER
1
2
3
F1
4
5
6
F2
F6
7
8
9
F3
F7
CLEAR
0
ENTER
F4
F8
F5
Pin # 1 2 3 4 5 6 7 8
Description Earth Ground Receive Transmit N/C N/C Ground +VDC Ground
NOTE: Pinouts are referenced to the terminal
TO HOST
COMM ADAPTER DB25-RJ45 W/PWR ACCU-TIME SYSTEMS INC.
3K232.DRW
MANU3000-01(01)
5
Page 9
For RS485 communication applications, ATS recommends using a data transmission cable that adheres to the following specifications: Five conductor shielded 24-gage wire with a drain. The impedance of the cable should be 100 Ohms. The capacitance should be 12 Pico-farads per foot. The jacket of the cable is typically either a PVC or Plenum material. (*NOTE* If the host is not equipped with an RS485 port, an ATS RS232/485 Converter with 12 volt power pack assembly will convert the terminal communication lines to RS232 levels. The host output of the RS232/485 Converter plugs directly into the ATS RS232 Communication Adapter). RS485 allows for the Series 3000 to be used in multi-dropped networks. Thirty-two (32) terminals can be supported on a single host communication port. The use of ATS Series 1000 Network Controllers allows up to five hundred and twelve (512) terminals on a single host communication port.
MULTI-CLOCK - RS485 INSTALLATION 1
2
3
5
4
E.GND
CO M M
1
2
3
5
4
6
7
8 P.GND
5
+VDC
4
P.GND
3
+VDC
2
8
P.GND
1
7
P.GND
E.GND
CO M M
6
6
7
8 P.GND
+VDC
P.GND
E.GND
COMM
Pin # 1 2 3 4 5 6 7 8
D C PO W ER JP1
NC
JP 2
JP 3
D RO P 1
JP 4 NC
NO
D RO P 2
DR OP 3
D RO P 4
NO
Description Earth Ground DI DO + DO DI + Ground +VDC Ground
E .GN D
NOTE: Pinouts are referenced to the terminal
12 VDC POWER SUPPLY
RS-232 TO RS-485 CONVERTER
TO HOST
NETWORK CONTINUED
COMM ADAPTER DB25-RJ45 W/PWR
12 VDC POWER SUPPLY LOW
ACCU-TIME SYSTEMS
ACCU-TIME SYSTEMS
EL LINGT ON, CT
EL LINGT ON, CT
INVALID
VALID
LOW
POWER
INVALID
VALID
POWER
1
2
3
F1
F5
1
2
3
F1
F5
4
5
6
F2
F6
4
5
6
F2
F6
7
8
9
F3
F7
7
8
9
F3
F7
CLEAR
0
ENTER
F4
F8
CLEAR
0
ENTER
F4
F8
MANU3000-01(01)
6
12 VDC POWER SUPPLY
Page 10
Terminal Face
Align the faceplate of the Series 3000 over the wall mount assembly. Plug the data cable through one of the perforated knockouts of the wall mount assembly into the communication port of the Series 3000. Attach the output of a 12VDC power pack assembly into the power port of the Series 3000 (note illustration). Plug the primary of the power pack assembly to the conventional wall outlet. With the terminal’s USE/TEST switch in the USE mode, attach the face to the wall mount assembly. Secure the assembly with the key lock. The Series 3000 will power-up and display the on-line default message. (Refer to the ATS SETUP MODE section of this manual for terminal communication setup parameters) Attach the remaining end of the data cable into the host computer port. The Series 3000 is now ready for operation.
R
ATS ACCU-TIME SYSTEMS ELLINGTON, CT LOW
INVALID
VALID
Wand Port
POWER
1
2
3
F5
4
5
6
F6
Host Communication Port
7
8
9
F7
T
CLEAR
0
ENTER
F4
F8
U
Test/Use Switch Power Port Optional UPS Battery
(Front of terminal)
(Back of terminal)
MANU3000-01(01)
7
DI/DO Port