The text of a manual · part 2 of 3
Series 2102 Accu-Touch 2 Time and Data Collection Terminal, pages 11 to 20
Pages 11 to 20 of 29
The original document is the PDF (243 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Time Series 2102
Page 11
For Ethernet communication applications, ATS recommends using a CATEGORY 5 unshielded twisted pair high-speed data transmission cable. One end of the 568B RJ45 terminated cable is plugged into the Series 2102 Ethernet port, while the other end is plugged into the network hub. RJ45 Pinouts Brown/White
8
White/Brown
7
Green/White
6
White/Blue
5
Blue/White
4
White/Green
3
Orange/White
2
White/Orange
1
Network
Pair 4
Pair 3
Pair 1
Pair 2
Pair 1 White/Blue Blue/White
Pair 2 Orange/White White/Orange
Pair 3 Green/White White/Green
Pair 4 Brown/White White/Brown
System Network Cable
Hub POWER SUPPLY
Ethernet Hub 10BASE-T ATS 12VDC POWER SUPPLY
ATS 12VDC POWER SUPPLY
ENROLL
ENROLL
8 MANU2102-01
Page 12
TEST ENROLLMENT ATS recommends that the first and second fingers of the same hand, right or left, be successfully “photographed” three (3) times to create the data template for enrollment. Remove and insert fingers for each of the 3 pictures. The three dimensional enrollment of the two fingers into a data template is one of the most essential aspects of the Series 2102 set-up. The following detailed enrollment procedure must be adhered to if consistent and accurate enrollments are to be assured. Actual enrollment is performed in the on-line or USE mode with each template matching a defined PIN number. This PIN number may be entered into the Series 2102 via the badge reader or keypad. Since the enrollment procedure may vary from application to application, the following approaches the enrollment process utilizing the ACCU-RATE test mode.
ACCU-RATE Test Enrollment: ▲ Place the Series 2102 TEST/USE switch in the TEST position. (Switch designation instructions are described in detail in the ACCU-RATE Set-up section of this manual.) ▲ The terminal will run through a power up sequence and display ATS TEST MODE. ▲ Press the Enter key. The terminal will display: ATS TEST MODE XXX YY ---------------------The display shows ATS TEST MODE on the top line followed by two sets of numbers. The first number (XXX) indicates the amount of memory installed (in Kilobytes). The right most number (YY) indicates the terminal’s Real Time Clock incrementing in seconds (00-59). !
Enter in the following number sequence to begin the test enrollment process: 3554649 followed by the Enter key. Note: The first finger sample enrolled is the most important and will contribute most heavily to the quality of the total enrollment process. Refer to the following Finger Positioning section for proper finger placement.
!
The terminal will display: PLEASE PLACE FINGERS FOR ENROLLMENT
!
If the two fingers were placed upon the platen within (18) seconds the six red LEDs will flash and the following message will be displayed: PLEASE PLACE FINGERS AGAIN FOR ENROLLMENT
!
Remove and present fingers again, as the terminal will require two more placements. The following message will appear for each of the placements. This process will take approximately four seconds. At this point, the fingers may be removed from the platen. The terminal will then display: PRESENT FINGERS
!
A small inverted pyramid of red LEDs will light, signifying that the terminal is ready to read. Present the fingers to verify the enrollment. NOTE: After the terminal reads the fingers correctly, all the red LEDs will flash once and a score will be displayed. The closer to 0 the score, the better the verification of the test enrolled template.
9 MANU2102-01
Page 13
Finger positioning: Finger positioning should be done with careful attention to the pyramid of red LEDs located below the keypad assembly. Correct finger placement:
Figure 1.
▲ The recommended index and middle fingers should be placed flat on the platen straddling/touching the pegs. ▲ Fold the thumb around the third and fourth fingers. ▲ The base between the two fingers should be touching the smaller front peg. The red LED indicators: If the top red light is activated, this indicates that the two fingers are too deep on the platen. Pull back a bit.
If the left light in the second row is illuminated, the right finger is touching the pegs but the left is not.
If the right light in the second row is illuminated, the left finger is touching the pegs but the right is not.
If the middle light in the last row of LEDs is lit, the fingers are not deep enough on the platen. Slide fingers towards the back of the platen.
10 MANU2102-01
Page 14
If the left outside light in the last row is activated, ensure that the hand is straight and not off to the left. The first and second fingers should be the only ones touching the platen.
If the right outside light in the last row of the pyramid is activated, ensure that the hand is straight and not off to the right. The first and second fingers should be the only ones touching the platen.
11 MANU2102-01
Page 15
ACCU-RATE SET-UP AND DIAGNOSTICS POWER UP To power up the Series 2102, a regulated 12VDC at 2½ amp source must be applied to the terminal power jack. The Series 2102, with the TEST/USE switch placed in the USE mode, beeps, executes a power up sequence and displays the message “TERMINAL LOCKED”. ACCESSING TEST MODE To access the test mode: 1) Unlock the terminal face from the base assembly on the Series 2102. 2) To locate the TEST/USE switch on the I/O board assembly, slide the terminal face straight out from the base being careful not to unplug the ribbon cables. 3) The switch is under the 34-pin ribbon cable and closest to the fuse. Slide the switch away from the phone jacks to enter the TEST position. 4) Reattach the faceplate to the base. The Series 2102 displays “ATS TEST MODE”. 5) By pressing the CLEAR key, the user can step through the selections. (*NOTE* Test mode may be exited at any time by placing the TEST/USE switch back to the USE position and pressing the CLEAR key.)
SELECTIONS: !
ATS TEST MODE: Tests the Keypad, Display, Memory, Real Time Clock, Bar Code/Magnetic slot reader, and Bar Code Wand circuitry.
!
ATS SET-UP MODE: Configures the communication parameters - Baud Rate, Parity Bit, Terminal Address, and Terminal Application Type.
!
ATS NETWORK TEST: Performs a terminal to host communication loop-back test. Verifies integrity of cabling.
!
ATS BATTERY TEST: For factory diagnostics only.
!
ATS DI-DO TEST: Checks the Digital Input/Digital Output auxiliary port by performing a loop-back test.
!
ATS RESTART MODE: Resets the terminal, clears all data from memory and performs a power-up sequence.
!
ATS AUX PORT TEST: For factory diagnostics only.
12 MANU2102-01
Page 16
ATS TEST MODE ATS TEST MODE checks the functionality of the terminal Keypad, Memory, Real Time Clock, Bar Code/Magnetic slot reader, and Bar Code Wand circuitry. To enter the TEST MODE, press the ENTER key. The message “ATS TEST MODE” appears on the top line of the display. The 2nd line of the display indicates the two program (EPROM) numbers. By pressing the ENTER key the following information appears. ATS TEST MODE (XXX) (YY) ----------------------The terminal displays ATS TEST MODE on the top line followed by two sets of numbers. The first number (XXX) indicates the amount of memory installed (in Kilobytes). The right most number (YY) indicates the terminal Real Time Clock incrementing in seconds (00-59). Testing the Keypad At this time the user may test the keypad assembly. Each time a key is pressed the terminal will beep and the key value will appear on the 2nd line of the display. Press the ENTER key. The message “KEY INPUT ACCEPTED” is displayed. Each time the ENTER key is pressed an internal test of the terminal communication port is performed. If an error is detected the message “COMM PORT FAIL” will display, the invalid light will flash and the negative acknowledgement beeper tone will cycle. This message will continue until power is removed from the terminal. Refer to the Troubleshooting Section of this manual. Testing the Badge Reader ATS TEST MODE accepts inputs from slot readers (optical, magnetic or Wiegand) and bar code wands. To test the reader, simply swipe the applicable media. The terminal beeps and displays the badge data. To test the bar code wand, the user lightly drags the tip of the wand across the bar code badge or label. The wand should be positioned in the hand (similar to that of a pen or pencil) at an approximate 30° angle. Begin the scanning process by dragging the wand horizontally, in a straight line, and at a constant speed across the entire label area. Each bar code label includes a preceding and trailing ¼ inch quiet zone. This area, which is free of any marks or bars, is a part of the bar code label and must be included when scanning the label. Upon the successful completion of a bar code read, the terminal will beep and display the data. To proceed to the ATS SETUP MODE press the CLEAR key. ATS SETUP MODE ATS SETUP MODE allows the operator to configure the terminal for communications with the host computer. The Series 2102 default parameters are set as follows: Baud Rate Parity Address Terminal Application Type
9600 ODD 01 A
To enter the ATS SETUP MODE, press the ENTER key at the “ATS SETUP MODE” display prompt. (Prior to pressing the ENTER key the 2nd line of the display will indicate the current terminal setup values.)
13 MANU2102-01
Page 17
Baud Rate To change the terminal baud rate: 1.
Press CLEAR to step through the baud rate choices: 19200 9600 4800 2400 1200 M1200 Not applicable M2400 Not applicable
2.
When the desired baud rate is displayed, press the ENTER key to store the value and advance to the next parameter. NOTE: Because an external modem is installed, it is suggested that no modem baud rate be selected. The modem self test will automatically fail.
Parity To change the parity: 1.
Press the CLEAR key to step through the parity choices: ODD EVEN NONE
2.
When the desired parity is displayed, press the ENTER key to store the value and advance to the next parameter.
Address To change the terminal address: 1.
Press the CLEAR key to increment the address values form 01 to 32.
2.
When the desired address is displayed, press the ENTER key to store the value and advance to the next parameter.
Terminal Application Type The Terminal Application Type is used as a delimiter by the host for routing application information to the terminal. (Example-an access control terminal could have a different terminal type than a time and attendance terminal.) To change the terminal application type: 1.
Press the CLEAR key to increment the type from A to J.
2.
When the desired type is displayed, press the ENTER key to store the value and advance to the ATS NETWORK TEST.
14 MANU2102-01
Page 18
ATS NETWORK TEST ATS NETWORK TEST is a two-part test. The first allows the network wiring between the terminal and the host to be checked for open connections or wiring errors. This test requires that the ATS RS232 Communication Adapter which is plugged into the host, be unplugged and pins 2 & 3 of the adapter jumped together (a paper clip should do the trick). Secondly, a local test can be performed on the terminal communication circuitry. This test will work for both RS232 and RS485 installations (RS485 installations require an ATS 232/485 Converter). If a modem is installed the Network Test is not applicable. To enter NETWORK TEST, press the ENTER key at the “ATS NETWORK TEST” prompt. The following message appears: SWITCH TEST SWITCH TO USE POSITION Place the switch on the back of the terminal into the USE position. The Series 2102 performs a network test in which the terminal sends data up to the host, via the network cabling. Since a temporary jumper was installed in the ATS RS232 Communication Adapter, the data will be looped back to the terminal. The following message should appear: NETWORK TEST PASS ENTER TO RETEST To perform the local communication loop back, place the USE/TEST switch back to the TEST position and press the ENTER key. The following message should appear: NETWORK TEST PASS ENTER TO RETEST Remove the jumper from the RS232 Communication Adapter and secure it back into the host port. Press the CLEAR key to advance to the next test.
ATS BATTERY TEST This test is for factory diagnostics only.
ATS DI/DO TEST The ATS DI/DO Test is a two-part test that checks the terminal auxiliary DATA IN/DATA OUT port connection by performing a loop back communication test on the port circuitry. To enter the ATS DI/DO Test: 1.
Press the Enter key at the “ATS DI-DO TEST” prompt. The following message should appear: SWITCH TEST SWITCH TO USE POSITION
2.
Place the test switch into the USE position. Since no loop back jumper is installed during this phase of testing the following message will appear: DI-DO TESTING DI-DO TEST FAILED ENTER TO RETEST
3.
Place the TEST/USE switch into the TEST position. This will provide the terminal with its own loop back jumper. 15
MANU2102-01
Page 19
4.
Press the ENTER key. The following message should appear: DI-DO TEST PASSED ENTER TO RETEST
5.
Press the CLEAR key to advance to ATS RESTART MODE.
ATS RESTART MODE The ATS RESTART MODE clears all transaction data and any download from memory. To restart the terminal: 1.
Press the ENTER key to select the ATS RESTART MODE. The terminal displays: PRESS ENTER TO CLEAR ALL TRANSACTION DATA
2.
Press the ENTER key. The terminal displays: CLEAR FOR CYCLE TEST (Note: Cycle test is for factory diagnostics only) ENTER FOR RESTART
3.
Press the ENTER key. The terminal displays: CLEARING MEMORY. . . The green Valid LED will blink and the terminal will execute a power up sequence and return the terminal back to the beginning of the Test Mode.
ATS AUX PORT TEST (For factory diagnostics only) To exit the Test Mode, place the TEST/USE switch to the USE position and press the CLEAR key. The terminal will execute a power up sequence. The terminal will display “TERMINAL LOCKED” and can now accept a host download.
This completes the ACCU-RATE test and set-up.
16 MANU2102-01
Page 20
ACCU-RATE ETHERNET SET-UP AND DIAGNOSTICS ATS TEST MODE checks the Ethernet circuitry installed in the terminals. To accurately test this circuit, please adhere to the following sequential steps. NOTE: The Ethernet communication cable must be connected to the time and data collection terminal with running Host software for this operation to be successful. With the “TEST MODE” message in the terminal display, press the CLEAR key five (5) times. The message “ATS RESTART MODE” appears on the top line of the display. Press the ENTER key three (3) times to clear all memory prior to testing the Ethernet circuit. (Omitting this step greatly increases the chances of unreliable test results in the Ethernet circuit). After resetting the terminal will again display “TEST MODE”. Press the CLEAR key one (1) time. The message “ATS SETUP MODE” Followed by: TERM 000.000.000.000 displayed for one (1) second Followed by: HOST 000.000.000.000 displayed for one (1) second Followed by: GATE 000.000.000.000 displayed for one (1) second (This message will only appear if the gate address was previously loaded) Followed by: MASK 000.000.000.000 displayed for one (1) second Followed by: BROADCAST ENABLED or DISABLED displayed for one (1) second Followed by: APP ACK ENABLED or DISABLED displayed for one (1) second Followed by: WATCHDOG ENABLED or DISABLED displayed for one (1) second The above sequence will repeat itself until either the CLEAR or ENTER key is pressed. Pressing the CLEAR key will bypass the test. Pressing the ENTER key will enable the test. Press the ENTER key. The following message will be displayed: TERMINAL IP ADDRESS
###. ###. ###. ###. _ _ _
This is the terminal's unique Internet Protocol address. (See your network administrator for assignment.) Enter, via the terminal keypad assembly, the numeric IP Terminal address in blocks of three followed by the ENTER key. Once all four octets are entered the following message will be displayed: HOST IP ADDRESS
###. ###. ###. ###. _ _ _
This is the Host’s unique Internet Protocol address. (See your network administrator for assignment.) Enter the numeric IP Host address in blocks of three followed by the ENTER key. Once all four blocks are entered the following message will be displayed: NETWORK MASK
###. ###. ###. ###. _ _ _
This is the Subnet Mask used for channeling. (See your network administrator for assignment). Enter the numeric Mask address in blocks of three followed by the ENTER key. Once all four blocks are entered the following message will be displayed: HIT ENTER IF DEFAULT ROUTE REQUIRED If a Router or Gateway is required press the ENTER key. The following message will be displayed: ROUTER IP ADDRESS ###. ###. ###. ###. _ _ _
17 MANU2102-01