SERIES 2102 ACCU-TOUCH®2 TIME AND DATA COLLECTION TERMINAL
Accu-Time Systems, Inc. 420 Somers Road, Ellington, CT 06029 Tel: (860) 870-5000 Fax: (860) 872-1511 Web Site: www.accu-time.com
Page 2
Copyright 2000 Accu-Time Systems, Inc. Accu-Time is a registered trademark of Accu-Time Systems, Inc. The material contained in this manual is subject to change. No part of this manual may be reproduced or distributed in any form or by any means, or stored in any database or retrieval system, without AccuTime’s prior written permission. Accu-Time Systems, Inc. makes no warranty of any kind including, but not limited to, and implied warrantees of merchantability, and fitness for a particular purpose in regard to this manual. All Rights Reserved. Printed in the USA.
Page 3
ACCU-TIME SERIES 2102
TABLE OF CONTENTS
Introduction Theory of Operation Features Specifications
1 2 3 4
Installation Test Enrollment
5 9
ACCU-RATE Diagnostics Ethernet Testing and Setup
12 17
Maintenance Troubleshooting Guide Ethernet Troubleshooting Guide
20 21 23
MANU2102-01
Page 4
INTRODUCTION The Accu-Time Series 2102 Accu-Touch2 is a complete biometric security package for any time and data collection environment. Versatile and dependable, the Series 2102 verifies a quick two-finger enrolment of either the right or left hand. By utilizing a dual peg finger-alignment feature, the Series 2102 is unparalleled in accuracy and ease of use. Offering automatic template updating, the Accu-Touch2 device adjusts to subtle variances in finger characteristics and positioning. The Series 2102 is complete with the capability to communicate in RS232, RS485 and Ethernet 10-base-T formats. Among the many features of the Series 2102 are: !
Multi-Media: Multiple cues, audio and visual, assist the user in the operation of the terminals. The Accu-Touch2 three dimensional finger geometry is a highly accurate and easy to use personal identification or verification product.
!
Flexibility: The Series 2102 works equally well with the right or left hand and also has an optional badge reader, making the device highly versatile. The terminal can act as a stand alone time station or as part of a local or wide area network. The ability to interface with virtually any host hardware or software platform gives the device a large range of communication possibilities.
!
Custom Applications: Custom programs and programmable function keys can provide users with the flexibility to create a variety of options.
!
Reliability: A Real Time Clock (RTC) provides 12 or 24 hour time formats with quartz precision. An optional non-interruptible power supply (UPS) provides terminal operation during power outages (up to 1.5 hours). Data storage will be preserved for up to 4 days with the memory backup system.
!
Durability: The durable enclosure protects circuitry from environmental conditions such as extreme temperatures and airborne dust. The terminal contains no moving parts and is housed behind a tough, environmentally resistant casing.
Versatility, Reliability and Affordability in a state-of-the-art ergonomically designed terminal and backed by the ACCU-TEAM.
1 MANU2102-01
Page 5
THEORY OF OPERATION The basic premise of the Series 2102 is to capture and store the geometric characteristics of the first and second finger on the right or left hand, for example. Although not required, the first two fingers of either hand are recommended for ease of use. This process is done to ensure proper and precise identification of an individual in a time and data collection environment. In order to accomplish this task, an essential function must occur; enrollment. In general terms, enrollment is a process used to capture and preserve the biometrics two finger image as a data template, which will later be used in the verification process. In order to capture the three-dimensional finger geometry during the enrollment, ATS incorporates the use of an optical chassis, opto-electronics, and electronic camera. This process automatically stores the information as a data template. To begin the enrollment process, the user first makes a primary identification claim by entering a personal identification number (PIN) by way of the keypad or swiping a card through a reader. The first and second fingers (recommended) are placed on the platen on either side of the two pegs and “photographed” three different times, removing and replacing the fingers each of the 3 times. The three dimensional image is captured and integrated with the PIN number, accelerating the verification process under normal operating conditions. The PIN and finger transaction must both be accomplished for a positive read even after enrollment. The enrollment template (finger geometry) may be stored inside the terminal, transferred to other terminals or uploaded to a host.
Template Updating The user’s finger data is modified and the template updated every time a successful transaction is completed (application dependent). The Series 2102 Accu-Touch2 is designed to track and update gradual alterations in finger shape that accompany aging, weight gain or loss, etc. and finger positioning.
2 MANU2102-01
Page 6
FEATURES •
Single or multi-clock environments on a variety of host platforms with application programs integrating the ATS DATA TRAKER family of modules.
•
128K byte capacitor back memory base, expandable to 768K
•
TCP/IP Ethernet 10-base-T compatible (802.3)
•
EIA Standard RS232 or RS485 compatible.
•
Up to 19.2 -baud modem operation
•
On-board ACCU-RATE terminal set-up and diagnostics package.
•
Custom keypad legends with software defined function keys.
•
Large sealed 20 key tactile 4x5 matrix keypad.
•
Dual tone audible annunciator
•
4 line x 20 Character liquid crystal backlit display
•
Integrated or External Bar Code readers
•
Magnetic slot or proximity readers
•
Individual user threshold values, automatic template updating, auto-recalibration
•
Dual DI/DO ports for access control
•
Optional Printer port
•
Low voltage power source locally or remotely supplied (consult factory for remote power)
•
Diagnostic LEDs for Ethernet - 2 yellow, 1 green, and 1 red.
•
Die cast aluminum housing with steel key-lockable, tamper resistant base assembly
•
FCC part 15 and CE Certified
3 MANU2102-01
Page 7
SPECIFICATIONS Display:
4 line x 20-character backlit super-twist LCD
Clock:
12 or 24 hour-format-USA or International (quartz precision) Time stamp of data transactions
Indicators:
Yellow LED low power indicator (on face of terminal) Two programmable LED indicators, RED and GREEN (on face of terminal) Diagnostic LEDs for Ethernet: Yellow = busy Green = linked Yellow = receive Red = Transmit Six red LED position indicators in pyramid form for finger positioning
Memory:
128K Byte of capacitor backed memory (i.e. 600-employee base-program dependent) Expandable to 768K Byte (Over 2000-employee base-program dependent)
Programming:
ATS DATA TRAKER modules, “C” programming language or third party custom application packages.
Interface:
TCP/IP Ethernet 10-base-T (802.3) EIA Standard RS232 or RS485 (2 or 4 wire) Standard AT Command set for up to 9600-Baud internal Modem operation Dual DI/DO or Serial Interface Printer ports
Enclosure:
Die cast aluminum housing with steel key-lockable base assembly
Power:
Regulated 12VDC @ 2½ amps Local, remote or centrally powered (consult factory for remote or central power) Non-interruptible power source with charger (optional)
Environment:
Operation: 32° to 110° F (0° to 43° C)
Certification:
FCC part 15 and CE Certified
Physical:
7.09” Length x 10.1” Width x 12.02” Height. Weight: 11.8 Lbs. (18.01cm length x 25.65cm width x 30.53cm height. Weight: 5.35)
Accessories:
Integrated or external Optical Bar Code slot readers Integrated magnetic slot readers Wiegand slot and RF ID readers Digital Bar Code Wands Solid State or Dry Contact relay modules Serial Interface Printer Port 4
MANU2102-01
Page 8
INSTALLATION GENERAL INSTALLATION GUIDELINES Environment Although the Series 2102 Time and Data Collection Terminal is a durable industrial-grade device, which will endure harsh environments, it never the less is an electronic device. Environmental constraints exist and care should be given when selecting a location for installing and operating the Series 2102. The ATS terminal is designed to operate indoors. Exposures to outdoor elements such as rain or snow will not only void the manufacturer warranty, but may cause damage to the device. Select a location, which has adequate lighting and accessibility to operate the terminal safely. Operating parameters Accu-Time recommends the Series 2102 operate in an ambient temperature range of between 32° and 110° Fahrenheit. Non-condensing humidity should be less than 95%. The terminal should be mounted on a vibration free area and out of direct sunlight. The back-plate should be mounted vertically with the finger platen approximately 43 inches from floor to terminal. The RS232 Series 2102 must be located no greater than fifty (50) wire-feet from the host computer. EIA standards for RS232 protocol data transmission dictate this cable distance. Exceeding this requirement greatly increases the chances for continual data re-transmission, which may never be acknowledged. The RS485 Series 2102 locally powered must be located no greater than five thousand (5000) wire-feet from the host computer. EIA standards for RS485 protocol data transmission dictate this cable distance. The Ethernet Series 2102 may be located at any point within a TCP/IP Ethernet 10-base-T Network, providing the single segment length from the network hub does not exceed three hundred and twenty-eight (328) wire-feet. A typical topology for the Series 2102 in an Ethernet 10-base-T network is a star configuration. Base Locate a flat wall surface to accommodate the Series 2102. Unlock and remove the top cover from the base. The bottom keyholes should be installed into the wall first and then the top holes. A mounting template is provided on the last page of this manual. With terminal power being supplied locally, insure that a conventional 110VAC-wall outlet, 220VAC in Europe and other areas, (check local electrical code requirements) is available to accept the Series 2102 12VDC power pack assembly. The outlet should be no further than four (4) feet from the terminal.
5 MANU2102-01
Page 9
For RS232 communication applications, one end of the communication cable terminates into the Series 2102 communication port while the other terminates into the host computer’s serial port via an ATS RS232 Communication Adapter. For remote powering, consult factory.
RS232 INSTALLATION
12 VDC POWER SUPPLY
Pin # 1 2 3 4 5 6 7 8
ENROLL
Description Earth Ground Receive Transmit N/C N/C Ground +VDC Ground
NOTE: Pinouts are referenced to the terminal
TO HOST
COMM ADAPTER DB25-RJ45 W/PWR
2101.232PO.DRW
For RS485 communication applications, ATS recommends using a data transmission cable that adheres to the following specifications:
Five conductor shielded 24-gage wire with a drain. The impedance of the cable should be 100 Ohms. The capacitance should be 12 pico-farads per foot. The jacket of the cable is typically PVC or Plenum material. (*NOTE* If the host is not equipped with an RS485 port, an ATS RS232/485 Converter with its own 12 volt power pack assembly will convert the terminal communication lines to RS232 levels. The host output of the RS232/485 converter plugs directly into the ATS RS232 Communication Adapter.) RS485 allows for the Series 2102 to be used in multi-dropped networks. Thirty-two (32) terminals can be supported on a single host communication port. The use of ATS Series 1000 Network Controllers allow up to 256 terminals on a single host communication port.
6 MANU2102-01
Page 10
MULTI-CLOCK - RS485 INSTALLATION
1
4
5
6
5
E.GND
CO M M
1
2
3
5
4
6
7
8 P.GND
4
P.GND
3
+VDC
2
1
6
7
8
Trunk Wire Network Cabling
P.GND
+VDC
P.GND
E.GND
COMM
8
P.GND
CO M M
7 +VDC
Description Earth Ground DI DO + DO DI + Ground +VDC Ground
3
P.GND
E.GND
Pin # 1 2 3 4 5 6 7 8
2
D C PO W ER JP2
JP1
NC
JP3
NO
JP4 NC
NO
12 VDC POWER SUPPLY
NOTE: Pinouts are referenced to the terminal D RO P 1
D RO P 2
DR OP 3
D RO P 4
E.G N D
COMM ADAPTER DB25-RJ45 W/PWR RS-232 TO RS-485 CONVERTER
TO HOST
NETWORK CONTINUED
12 VDC POWER SUPPLY ENROLL
ENROLL
12 VDC POWER SUPPLY
7 MANU2102-01