Page 173

Appendix A: Biometrics

Fingerprint Scanner Types

E-Field Sensor (Bioscrypt) Figure A-4 illustrates how an E-Field sensor operates to create a fingerprint image. It shows a cross-section of an E-Field sensor array reading the skin layers of a finger.

Figure A-4

E-Field Sensor Image Creation

Live skin cell layer

Conductive Ring

Outer Dead Skin Layer (Dielectric) Excitation Generator

Skin Surface

Pixel Antenna Array Semiconductor Substrate Excitation Signal Reference Plane

Capacitive Sensor (Cogent, Suprema, Crossmatch/Digital Persona) Capacitive sensors use active capacitive pixel-sensing technology to detect the finger ridge and valley patterns. They measure the capacitance of the finger to obtain an image. The capacitance of the finger changes as the distance between the finger and the array changes, C1, C2 and C3, as show in Figure A-5.

Figure A-5

Capacitive Sensor Image Creation

Air Surface Passivation

C3

Skin Surface C1

C2

Capacitor Array

Active Circuits Silicon Substrate

MANU-MAXIMUS-02 Revision-02

Maximus Reference Manual

A-9

Page 174

Fingerprint Scanner Types

Appendix A: Biometrics

Multi-Spectral Imaging Sensor (Lumidigm) The AccuTouch reader uses multi-spectral imaging to authenticate fingerscans. The multispectral sensor has the ability to “see” structures beneath the skin surface (subcutaneous structures). Your “internal fingerprint” is identical to your external fingerprint as illustrated in Figure A-6.

Figure A-6

Internal and External Fingerprint (Source: Lumidigm Corporation)

The blood vessels and other skin structures are easily imaged with the multispectral approach. Figure A-7 shows how oxygenated hemoglobin in blood affects absorption depending on the wavelength of light.

Figure A-7

A-10

Optical Absorption Due to Blood (Source: Lumidigm Corporation)

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 175

Appendix A: Biometrics

Fingerprint Scanner Types

Figure A-8 shows how collagen pushing between blood vessels creates ridges in the finger tip.

Figure A-8

Relevant Fingertip Physiology (Simone Sangiogi 2006, Source: Lumidigm Corporation) Surface ridges form by collagen pushing between the blood vessels (the photo on the left has the collagen removed for clarity)

Blood Vessels

Multi-spectral optical fingerprinting using multiple, different images taken on a single reader during a single finger placement offers the following advantages:

MANU-MAXIMUS-02 Revision-02

•

Multiple authentication images at enrollment and during authentication

•

Multiple scanning wavelengths

•

Different optical geometries

•

Surface and subsurface feature identification

•

Surface penetration up to 1500 microns deep (1.5 mm)

•

“Single reader, single finger placement” for authentication

•

No extra user actions

Maximus Reference Manual

A-11

Page 176

Finger Placement

Appendix A: Biometrics

Finger Placement Filling the sensor area with the fingerprint provides the best performance. Touching the sensor with a fingertip, as if pressing a button, creates scan that lacks information-rich fingerprint data resulting in a rejected authentication. Don’t slide your finger onto the finger scanner, as this can push debris onto the sensor.

Caution

NOTE:

For finger scans, we recommend you use an index finger, middle finger, or a ring finger, in that order. We do not recommend using a thumb.

Placement Guides E-Field (Bioscrypt) and Capacitive (Suprema and Cogent) sensors are equipped with a placement guide. The placement guide is a raised area located in front of the sensor to aid in finger positioning. Users should center the bottom of their first joint on the placement guide before lowering their finger onto the sensor. Figure A-9 shows the placement guide in front of an E-Field sensor.

Figure A-9

Placement Guide in Front of a Sensor (E-Field shown)

Placement Guide

When the terminal displays a message such as “Place finger on reader” or “Present Finger”, slide your finger across the placement guide without touching the sensor until the first joint is centered on the placement guide.

A-12

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 177

Appendix A: Biometrics

Figure A-10

Finger Placement

Knuckle Placement for Finger Scanner

Press the pad of your finger gently and constantly against the finger scanner

First knuckle rests on the placement guide

Use the following procedure to authenticate your fingerprint:

Figure A-11

•

Align: Position the finger where the center of the first joint meets the center of the placement guide as shown in Figure A-10.

•

Drop: Lower the finger evenly onto the sensor using moderate pressure as shown in Figure A-11.

•

Hold: Keep the finger on the sensor until the display shows the acceptance/ rejection message (e.g., “Your finger has been accepted”).

Correct Finger Placement on a Finger Scanner – Side View

Sensors Without Placement Guides Many multi-spectral sensors, such as the AccuTouch (Lumidigm), do not have a placement guide. Use the following procedure to enroll on a multi-spectral sensor (refer to Figure A-12):

MANU-MAXIMUS-02 Revision-02

1.

Straighten your finger.

2.

Position the pad of your finger above the center of the sensor.

3.

Keep your finger straight and lower the pad of your finger evenly onto the center of the sensor.

Maximus Reference Manual

A-13

Page 178

Finger Placement

Appendix A: Biometrics

4.

Figure A-12

Without moving or rolling your finger, hold the pad of your finger on the sensor with moderate pressure until the system reads and verifies/identifies the scan.

Correct Finger Placement on an AccuTouch Finger Scanner

Authentication Issues Common issues that produce a rejected authentication are: •

Position: Placing your finger far from the center position of the sensor will increase the rejection rate.

•

Rotation: Finger rotation should be kept to a minimum during enrollment and verification.

•

Pressure: Apply moderate pressure when making contact with the sensor. Too much pressure may cause smudging of the fingerprint. Too little pressure may not allow the sensor to recognize the presence of a finger.

Figure A-13 shows correct and incorrect finger placements.

A-14

Maximus Reference Manual

MANU-MAXIMUS-02 Revision-02

Page 179

Appendix A: Biometrics

Figure A-13

Finger Placement

Correct and Incorrect Finger Placements

Position

Rotation

Pressure