Spec sheet · Accu-Time

Accu-Time Biometric Cyber Series Time and Data Collection Terminal Spec Sheet

Spec sheet2 pagesPDF 182 KB

The text of both pages is below; the pictures of the pages are in the PDF.

What this file really is

The old site listed this file as a spec sheet for the Accu-Time CS2100 and CSS110. The sheet is the Cyber Series and never gives CS2100 or CSS110.

Download the PDF182 KB

Filed with · 2 models

Also filed with these models on the old site

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

A two-page sheet for the Accu-Time Biometric Cyber Series time and data collection terminal, with terminal types CSSB, CSEB, CS1B, CS2B and CS3B. It lists the features, specifications and accessories; it does not name the CS2100 or CSS110.

What it is
Biometric time and data collection terminal with an E-field or capacitive finger scan sensor p. 1
Display
4 line x 20 character super twist LCD p. 2
Keypad
20-key tactile 4x5 matrix, software-defined function keys, custom legends p. 2
Memory
Up to 1MB RAM, up to 512k flash p. 1, 2
Interfaces
RS232 or RS485; optional 10/100BASE-T Ethernet, internal modem, DI/DO or serial printer port p. 2
Power
+10 to +17 VDC (12 nominal); optional non-interruptible power source with charger p. 2
Operating temperature
32˚ to 110˚F (0˚ to 43˚C) p. 2
Size
7.25" x 10" x 4" (18.4cm x 25.4cm x 10.2cm) p. 2
Weight
2.45 lbs. (2.2 kg.) p. 2
Programming
ATS Universal Command Set, C, or third-party application packages p. 2
Enclosure
Die cast aluminum housing with key-lockable base p. 2
Clock
12 or 24 hour format, time stamp on transactions p. 2
Readers
Bar code wand port; optional visible or infrared bar code slot, magnetic slot, and proximity readers p. 1, 2
Certifications
The sheet states CE Mark, FCC Part 15 and Part 68 p. 2

What this sheet walks you through

  • Cyber Series features and specifications p. 1, 2
  • Terminal types and their options p. 2

Questions this sheet answers

What kind of fingerprint sensor does the Accu-Time Cyber Series use?

A choice of E-field or capacitive finger scan sensor. p. 1

What power does the Cyber Series terminal need?

+10 to +17 VDC, 12 nominal, with an optional non-interruptible power source and charger. p. 2

Does the Cyber Series clock have Ethernet?

Ethernet (802.3 10/100BASE-T) is optional; the interfaces also include RS232 or RS485. p. 2

How is the Cyber Series programmed?

With the ATS Universal Command Set, the C language or third-party application packages; it has on-board setup and diagnostics. p. 2

The file

Size and text

Pages2
PDF182 KB
TextText from the PDF itself.

Every page · 2

Read it here

The words of each page, so a phone can search and copy them. The pages themselves are in the PDF.

The text of page 1, from the PDF itself

Cyber CYBER SERIES

The Biometric Cyber Series is a time and data collection terminal that sets a new standard in the industry by incorporating your choice of two proven finger scan technologies: E-field or capacitive sensor. The Cyber Series is able to provide security that will save your company money through the elimination of buddy-punching and time theft. Enjoy all the benefits of Biometric technology in the Cyber Series without having to break the bank.

  • Single or multi-clock environment
  • Up to 1MB of RAM
  • Up to 512KB Flash
  • EIA Standard RS232 or RS485 compatible
  • 10/100BASE-T Ethernet
  • Fingerprint E-field or capacitive sensor technology
  • On-board setup and diagnostics utility
  • Digital bar code wand port
  • Expansion slot for support of plug-in options
  • External proximity reader support

Answers for HR Professionals™ To learn more about ATS and the Cyber Series, visit www.accu-time.com or call 860-870-5000.

Biometric

The text of page 2, from the PDF itself

Cyber

Specifications DISPLAY

4 line x 20 character super twist LCD

CLOCK

12 or 24 hour format, USA or international (quartz precision) Time stamp of data transactions

KEYPAD

Software-defined function keys Large 20-key tactile 4x5 matrix Custom user-defined keypad legends

MEMORY

Accu-Time Systems, Inc. One Accu-Time Plaza Route 83 Ellington, CT 06029 1-800-355-4648 www.accu-time.com

Up to 1MB RAM available Up to 512k flash memory

TEL: (860) 870-5000 FAX: (860) 872-1511 EMAIL: sales@accu-time.com

PROGRAMMING ATS Universal Command Set, C programming language, or third-party custom application packages On-board setup and full-feature diagnostics

INTERFACE

802.3 10/100BASE-T Ethernet (optional) EIA Standard RS232 or RS485 Internal modem (optional) Optional DI/DO or serial interface printer port

ENCLOSURE

Die cast aluminum housing with key-lockable base

POWER

+10 to +17 VDC (12 nominal) Optional non-interruptible power source with charger

ENVIRONMENT

Operation: 32˚ to 110˚F (0˚ to 43˚C)

PHYSICAL

Size: 7.25” x 10” x 4” (18.4cm x 25.4cm x 10.2cm) Weight: 2.45 lbs. (2.2 kg.)

Accu-Tech Systems Ltd 31 Venture Wales Bedwas House Business Park Caerphilly South Wales United Kingdom CF83 8DW +44 (0) 2920 885599 www.accu-tech.co.uk

CERTIFICATIONS CE Mark, FCC Part 15 and Part 68 ACCESSORIES

Biometric

  • Integrated visable or infrared bar code slot readers
  • Integrated magnetic slot readers
  • Solid state or dry contact relay modules
  • Integrated or external proximity readers
  • Serial interface printer port

Cyber Series Biometric Configuration Guide Terminal Type

Display

CSSB CSEB CS1B CS2B CS3B

4x20 4x20 4x20 4x20 4x20

10M--Std. -------Ethernet 10/100M------Std. Std.Modem MemoryOpt. --Opt. Opt. Opt.

128K 128K 512K 512K 1MB

Flash

256K 256K 256K 256K 512K

Mounting Prox. DI/DO

Gull Gull Lock Lock Lock

----Opt. Opt. Opt.----Opt. Opt. Opt.1 to 1 w/pin1 to X no pin

Std. Std. Std. Std. Std.

Opt. Opt. Opt. Opt. Opt.

Connecticut • Chicago • Sarasota • Boston • United Kingdom