Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 10

Model 30 Hardware Operations Manual, pages 31 to 40

Pages 31 to 40 of 96

The original document is the PDF (557 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Accu-Sort Model 30

Page 31

2-9

What to Do After Receiving Your Model 30

Mounting the Photoeye

This section describes how to mount your photoeye to the photoeye mounting bracket. Photoeyes work by bouncing a light beam off a reflector and detecting when something breaks the path of light. In order for your photoeyes to work properly, you must make sure the following things are done: • The photoeye must have a reflector mounted directly opposite it on the other side of the conveyor. • The photoeye must be mounted so the light exit window is perpendicular to the conveyor, facing the reflector. • The reflector must be mounted perpendicular to the conveyor, facing the photoeye. Use the drawing below to help you mount your photoeye. The table below provides information pertaining to each item number in the drawing.

Reflector Mtg Surface Photoeye Mtg Brkt Surface

Photoeye Mounting Diagram Use the following table to match item numbers with the photoeye mounting diagram above: Quantity Required

Description

Part Number

Item Number

1

#8-32 Nut

N#8-32

11

1

#8 Internal Tooth Lock Washer

L#8

10

1

#8 Flat Washer

W#8

9

1

3" Reflector

C110MH

8

1

8-32 2" Machined Pan HD

8-32X2MPHZP

7

1

Model 30 P.E. Mtg. Bracket

A-33055

6

2

#6-32 Nut

N#6-32

5

2

#6 Internal Tooth Lock Washer

L#6

4

4

#6 Flat Washer

W#6

3

2

6-32 2" Machined Pan HD

6-32X2MPHZP

2

1

Polorized Photoeye

B-33107

1

Model 30 Hardware Operations Manual

Page 32

2-10

Setting Up Your Model 30

Chapter 2

The steps below are one recommended way to set up your Model 30 Scanning System: 1.

Remove all materials from the box.

2.

Check the materials against the packing list and make sure everything is there.

3.

Make sure none of the parts are broken.

4.

Make all the appropriate connections to your Model 30 as explained in Chapter Three.

5.

Mount your Model 30 as described earlier in this chapter.

6.

Begin reading your bar codes.

If you have any problems or questions concerning setting up your Model 30, contact Accu-Sort immediately (refer to the Customer Service Section of this manual.)

Accu-Sort Systems

Page 33

Chapter

3

Making Model 30 Connections

Chapter Contents Introduction ..................................................................................... 3-1 Model 30 External Connections .................................................... 3-2 Providing Power To Your Model 30 ............................................ 3-3 Connecting Your Model 30 To A Decoder Logic ....................... 3-4 Supplying A Trigger Input To Your Model 30........................... 3-5

Page 34

Chapter 3

Accu-Sort Systems

Page 35

Making Model 30 Connections

Introduction

3-1

This chapter explains how to supply power to your Model 30, and how to connect your Model 30 to a decoder logic or a trigger input. You must make these connections before you can begin setting up or using your Model 30.

Model 30 Hardware Operations Manual

Page 36

3-2

Chapter 3

Model 30 External Connections

There are two external connections that can be made to the Model 30: • Logic (J1) • Photoeye (J2) These connections are shown below and described in detail on the next few pages:

ACCU-SORT SYSTEMS, iNC. TELFORD, pa 18969 USA

SERIAL WWXXXXXX

DATE

January 1, 2000

J1

J2

J2 9 PIN (D) FEMALE PHOTOEYE CONNECTOR (TRIGGER INPUT)

J1 9 PIN (D) MALE LOGIC CONNECTOR

Model 30 Connector Panel

Accu-Sort Systems

Page 37

3-3

Making Model 30 Connections

Providing Power To Your Model 30 J1 9 PIN (D) MALE LOGIC CONNECTOR

The power connector on the Model 30 is port J1, the 9-pin male logic connector, as shown on the connector panel cutout to the left. The Model 30 is designed to operate from a power source of +12VDC +/- 1 Volt. (The input current required is less than 0.5 amp.) This power source is provided from the decoder logic. When the logic is powered up, so is the Model 30. The Model 30 then transfers signals to the logic through port J1.

J1

See page 3-2 for a full view of the Model 30 connector panel.

The drawing below shows the power input requirements for the Model 30 and any connecting equipment. MODEL 30 SCAN HEAD

VIBRATING VANE ASSEMBLY

!

CAUTION

WARNING: Do not make any connections to the Model 30 while the unit is receiving power from the connected logic unit.

ALLOWABLE INPUT VOLTAGE RANGE V+ 11.O TO 14.0 VDC

@

IS 600mA MAX

+

IV 200mA MAX

=

IT 800mA MAX

NOTES: 1) ACTUAL CURRENTS ARE DEPENDENT ON SUPPLY VOLTAGE V+ 2) IS IS A FUNCTION OF SCAN RATE. (I S MIN = APPROX. 400mA @ MIN SCAN RATE) 3) IV IS A FUNCTION OF VANE PERIOD. (IV MIN = APPROX. 100 mA @ MIN VANE PERIOD)

Model 30 Power Input Requirements

Model 30 Hardware Operations Manual

Page 38

3-4

Chapter 3

Connecting Your Model 30 To A Decoder Logic J1 9 PIN (D) MALE LOGIC CONNECTOR

The Logic connector on the interface box is a 9 pin "D" male, labelled LOGIC (J1), as shown on the connector panel cutout to the left. Use the Accu-Sort Interconnect Cable (part # 5473C) to connect your scanner to the logic. If you do not purchase this cable, you can create your own. The following drawings show the pin connections for the designated LOGIC (J1) connector on the Model 30. Use these drawings to help you make a cable to connect your logic to the Model 30.

J1

See page 3-2 for a full view of the Model 30 connector panel.

DEM-9S C88300004

9000 9000 DRX

DEM-9S C88300004

GRN WHT SCAN 1 1 CODE 22 3 3 DECODE 1 2345 WHT 4 4 CODE TRIGGER 55 BLK 6 6 TRIGGER/ENABLE BLK GND 6789 77 BLK 8 8 GND RED 9 9 V+ BLK(RED)

SCAN J1P1GRN 11 CODE 22 DECODE 3 3 CODE 4 4 WHT 1 2345 TRIGGER 55 TRIGGER/EN6 6 BLK ABLE GND 7 7 BLK 6789 GND 8 8 BLK V+ 9 9 RED

GRN

DECODER LOGIC

ASSY# 3012

MODEL 30 STANDARD WHT

GRN

RED BLK(WHT) BLK(GRN)

RED BLK(WHT) BLK(GRN) SHIELD

WIRING VIEW

WIRING VIEW

BLK(RED)

RECOMMENDED CABLE TYPE ALPHA P/N 5473C OR EQUIVALENT MAXIMUM CABLE LENGTH: 50 FT.

ASSY# 3012A

* MODEL 30GR GUN REPLACEMENT

DEM-9S

BLK(GRN) GRN C88300004 J1 P1 WHT SCAN 11

1234 5

CODE 2 2 WHT DECODE BLK

6 78 9

TRIGGER 5 5 GRN TRIGGER/EN- 6 6 BLK ABLE GND BLK

33 CODE 4 4 77

GND 8 8 RED +12V 9 9 RED BLK(RED) BLK(WHT)

1150 1200 1400

DECODER LOGICS (STD) 4410 (STD) (STD) 4710 (SPECIAL) (STD) 4810 (SPECIAL)

207752-1 1-66505-0 61831-1 GUN WHT BLK(GRN) 745002-2 PORT GRN 1 1 SCAN WHT 2 2 CODE 3 5 2 4 1 BLK 3 3 DECODE 44 GRN 5 5 TRIGGER BLK 6 6 +12V CONTROL 67 89 BLK 7 7 GND RED GND 88 +12V RED 99 BLK(WHT)

WIRING VIEW

BLK(RED)

WIRING VIEW

*JUMPERS E12 AND E1 ON RECOMMENDED CABLE TYPE A/D BOARD MUST BE IN ALPHA P/N 5473C OR EQUIVALENT POSITION 2-3. MAXIMUM CABLE LENGTH 20 FT.

Pin Connections for Connecting Your Logic to the Model 30

Accu-Sort Systems

SHIELD

Page 39

3-5

Making Model 30 Connections

Supplying A Trigger Input To Your Model 30

A triggering device can be used to supply an electronic signal or pulse to inform the scanner of the presence of an object within its reading zone. The trigger connector on the Model 30 is a 9 pin "D" female, labelled PHOTOEYE (J2), as shown on the connector panel cutout to the left. The drawing below shows the internal wiring of the trigger circuit.

J2 9 PIN (D) FEMALE PHOTOEYE CONNECTOR

+5V

J2

5 4 3 2 1 2 . 2K

9 8 7 6

1 A 2 2 0 K 2 74HC132

J2 OUTSIDE VIEW P2 INSIDE VIEW DEM - 9P

See page 3-2 for a full view of the Model 30 connector panel.

NORMALLY NORMALLY OPEN CLOSED

3

+5V 2 . 2K

P2 J2 TRIGGER 1 1 TRIGGER 2 2 GND 3 3 4 4 V+ 5 5 I6 6 I+ 7 7 GND 8 8 TRIGGER INV 9 9 ANLG CODE

220K

IL217

4 B 5 74HC132

6

HTRIGGER

INTERNAL CIRCUITRY 30 D - 33025 REV. 1

2 . 4K 0 . 25W 7406

RESET ON POWER UP

DRY CONTACTS: MINIMUM CURRENT RATING = 2mA OR LESS

Internal Wiring for Photoeye (J2) Connection

The following drawings represent some common triggering inputs the Model 30 uses.

DEM - 9P P2 1

NORMALLY OPEN

J2 1

TRIGGER TRIGGER

2

2

3

3

4

4

V+

5

5

I-

6

6

7 8

7 8

9

9

GND

I+ GND TRIGGER INV ANLG CODE

DRY CONTACTS: MINIMUM CURRENT = 2mA OR LESS RATING CONTACT BOUNCE = 5mS OR LESS

Wiring Your Model 30 to a (Form A) Triggering Input

Model 30 Hardware Operations Manual

Page 40

3-6

Chapter 3

DEM - 9P P2 1 2

J2 1 2

3

3

4

4

V+

5

5

I-

6

6

7

7

8

8

9

9

12 - 24 VOLT DC NORMALLY OV OR OPEN

TRIGGER TRIGGER GND

I+ GND TRIGGER INV ANLG CODE

Wiring Your Model 30 to a (12-24 Volt) Triggering Input

74XX NORMALLY HIGH

DEM - 9P P2 1

J2 1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

TRIGGER TRIGGER GND V+ II+ GND TRIGGER INV ANLG CODE

MODEL 30 REPRESENTS APPROXIMATELY 2 TTL LOADS

Wiring Your Model 30 to a (TTL) Triggering Input

Accu-Sort Systems