Page 31
2-9
What to Do After Receiving Your Model 30
Mounting the Photoeye
This section describes how to mount your photoeye to the photoeye mounting bracket. Photoeyes work by bouncing a light beam off a reflector and detecting when something breaks the path of light. In order for your photoeyes to work properly, you must make sure the following things are done: • The photoeye must have a reflector mounted directly opposite it on the other side of the conveyor. • The photoeye must be mounted so the light exit window is perpendicular to the conveyor, facing the reflector. • The reflector must be mounted perpendicular to the conveyor, facing the photoeye. Use the drawing below to help you mount your photoeye. The table below provides information pertaining to each item number in the drawing.
Reflector Mtg Surface Photoeye Mtg Brkt Surface
Photoeye Mounting Diagram Use the following table to match item numbers with the photoeye mounting diagram above: Quantity Required
Description
Part Number
Item Number
1
#8-32 Nut
N#8-32
11
1
#8 Internal Tooth Lock Washer
L#8
10
1
#8 Flat Washer
W#8
9
1
3" Reflector
C110MH
8
1
8-32 2" Machined Pan HD
8-32X2MPHZP
7
1
Model 30 P.E. Mtg. Bracket
A-33055
6
2
#6-32 Nut
N#6-32
5
2
#6 Internal Tooth Lock Washer
L#6
4
4
#6 Flat Washer
W#6
3
2
6-32 2" Machined Pan HD
6-32X2MPHZP
2
1
Polorized Photoeye
B-33107
1
Model 30 Hardware Operations Manual
Page 32
2-10
Setting Up Your Model 30
Chapter 2
The steps below are one recommended way to set up your Model 30 Scanning System: 1.
Remove all materials from the box.
2.
Check the materials against the packing list and make sure everything is there.
3.
Make sure none of the parts are broken.
4.
Make all the appropriate connections to your Model 30 as explained in Chapter Three.
5.
Mount your Model 30 as described earlier in this chapter.
6.
Begin reading your bar codes.
If you have any problems or questions concerning setting up your Model 30, contact Accu-Sort immediately (refer to the Customer Service Section of this manual.)
Accu-Sort Systems
Page 33
Chapter
3
Making Model 30 Connections
Chapter Contents Introduction ..................................................................................... 3-1 Model 30 External Connections .................................................... 3-2 Providing Power To Your Model 30 ............................................ 3-3 Connecting Your Model 30 To A Decoder Logic ....................... 3-4 Supplying A Trigger Input To Your Model 30........................... 3-5
Page 34
Chapter 3
Accu-Sort Systems
Page 35
Making Model 30 Connections
Introduction
3-1
This chapter explains how to supply power to your Model 30, and how to connect your Model 30 to a decoder logic or a trigger input. You must make these connections before you can begin setting up or using your Model 30.
Model 30 Hardware Operations Manual
Page 36
3-2
Chapter 3
Model 30 External Connections
There are two external connections that can be made to the Model 30: • Logic (J1) • Photoeye (J2) These connections are shown below and described in detail on the next few pages:
ACCU-SORT SYSTEMS, iNC. TELFORD, pa 18969 USA
SERIAL WWXXXXXX
DATE
January 1, 2000
J1
J2
J2 9 PIN (D) FEMALE PHOTOEYE CONNECTOR (TRIGGER INPUT)
J1 9 PIN (D) MALE LOGIC CONNECTOR
Model 30 Connector Panel
Accu-Sort Systems
Page 37
3-3
Making Model 30 Connections
Providing Power To Your Model 30 J1 9 PIN (D) MALE LOGIC CONNECTOR
The power connector on the Model 30 is port J1, the 9-pin male logic connector, as shown on the connector panel cutout to the left. The Model 30 is designed to operate from a power source of +12VDC +/- 1 Volt. (The input current required is less than 0.5 amp.) This power source is provided from the decoder logic. When the logic is powered up, so is the Model 30. The Model 30 then transfers signals to the logic through port J1.
J1
See page 3-2 for a full view of the Model 30 connector panel.
The drawing below shows the power input requirements for the Model 30 and any connecting equipment. MODEL 30 SCAN HEAD
VIBRATING VANE ASSEMBLY
!
CAUTION
WARNING: Do not make any connections to the Model 30 while the unit is receiving power from the connected logic unit.
ALLOWABLE INPUT VOLTAGE RANGE V+ 11.O TO 14.0 VDC
@
IS 600mA MAX
+
IV 200mA MAX
=
IT 800mA MAX
NOTES: 1) ACTUAL CURRENTS ARE DEPENDENT ON SUPPLY VOLTAGE V+ 2) IS IS A FUNCTION OF SCAN RATE. (I S MIN = APPROX. 400mA @ MIN SCAN RATE) 3) IV IS A FUNCTION OF VANE PERIOD. (IV MIN = APPROX. 100 mA @ MIN VANE PERIOD)
Model 30 Power Input Requirements
Model 30 Hardware Operations Manual
Page 38
3-4
Chapter 3
Connecting Your Model 30 To A Decoder Logic J1 9 PIN (D) MALE LOGIC CONNECTOR
The Logic connector on the interface box is a 9 pin "D" male, labelled LOGIC (J1), as shown on the connector panel cutout to the left. Use the Accu-Sort Interconnect Cable (part # 5473C) to connect your scanner to the logic. If you do not purchase this cable, you can create your own. The following drawings show the pin connections for the designated LOGIC (J1) connector on the Model 30. Use these drawings to help you make a cable to connect your logic to the Model 30.
J1
See page 3-2 for a full view of the Model 30 connector panel.
DEM-9S C88300004
9000 9000 DRX
DEM-9S C88300004
GRN WHT SCAN 1 1 CODE 22 3 3 DECODE 1 2345 WHT 4 4 CODE TRIGGER 55 BLK 6 6 TRIGGER/ENABLE BLK GND 6789 77 BLK 8 8 GND RED 9 9 V+ BLK(RED)
SCAN J1P1GRN 11 CODE 22 DECODE 3 3 CODE 4 4 WHT 1 2345 TRIGGER 55 TRIGGER/EN6 6 BLK ABLE GND 7 7 BLK 6789 GND 8 8 BLK V+ 9 9 RED
GRN
DECODER LOGIC
ASSY# 3012
MODEL 30 STANDARD WHT
GRN
RED BLK(WHT) BLK(GRN)
RED BLK(WHT) BLK(GRN) SHIELD
WIRING VIEW
WIRING VIEW
BLK(RED)
RECOMMENDED CABLE TYPE ALPHA P/N 5473C OR EQUIVALENT MAXIMUM CABLE LENGTH: 50 FT.
ASSY# 3012A
* MODEL 30GR GUN REPLACEMENT
DEM-9S
BLK(GRN) GRN C88300004 J1 P1 WHT SCAN 11
1234 5
CODE 2 2 WHT DECODE BLK
6 78 9
TRIGGER 5 5 GRN TRIGGER/EN- 6 6 BLK ABLE GND BLK
33 CODE 4 4 77
GND 8 8 RED +12V 9 9 RED BLK(RED) BLK(WHT)
1150 1200 1400
DECODER LOGICS (STD) 4410 (STD) (STD) 4710 (SPECIAL) (STD) 4810 (SPECIAL)
207752-1 1-66505-0 61831-1 GUN WHT BLK(GRN) 745002-2 PORT GRN 1 1 SCAN WHT 2 2 CODE 3 5 2 4 1 BLK 3 3 DECODE 44 GRN 5 5 TRIGGER BLK 6 6 +12V CONTROL 67 89 BLK 7 7 GND RED GND 88 +12V RED 99 BLK(WHT)
WIRING VIEW
BLK(RED)
WIRING VIEW
*JUMPERS E12 AND E1 ON RECOMMENDED CABLE TYPE A/D BOARD MUST BE IN ALPHA P/N 5473C OR EQUIVALENT POSITION 2-3. MAXIMUM CABLE LENGTH 20 FT.
Pin Connections for Connecting Your Logic to the Model 30
Accu-Sort Systems
SHIELD
Page 39
3-5
Making Model 30 Connections
Supplying A Trigger Input To Your Model 30
A triggering device can be used to supply an electronic signal or pulse to inform the scanner of the presence of an object within its reading zone. The trigger connector on the Model 30 is a 9 pin "D" female, labelled PHOTOEYE (J2), as shown on the connector panel cutout to the left. The drawing below shows the internal wiring of the trigger circuit.
J2 9 PIN (D) FEMALE PHOTOEYE CONNECTOR
+5V
J2
5 4 3 2 1 2 . 2K
9 8 7 6
1 A 2 2 0 K 2 74HC132
J2 OUTSIDE VIEW P2 INSIDE VIEW DEM - 9P
See page 3-2 for a full view of the Model 30 connector panel.
NORMALLY NORMALLY OPEN CLOSED
3
+5V 2 . 2K
P2 J2 TRIGGER 1 1 TRIGGER 2 2 GND 3 3 4 4 V+ 5 5 I6 6 I+ 7 7 GND 8 8 TRIGGER INV 9 9 ANLG CODE
220K
IL217
4 B 5 74HC132
6
HTRIGGER
INTERNAL CIRCUITRY 30 D - 33025 REV. 1
2 . 4K 0 . 25W 7406
RESET ON POWER UP
DRY CONTACTS: MINIMUM CURRENT RATING = 2mA OR LESS
Internal Wiring for Photoeye (J2) Connection
The following drawings represent some common triggering inputs the Model 30 uses.
DEM - 9P P2 1
NORMALLY OPEN
J2 1
TRIGGER TRIGGER
2
2
3
3
4
4
V+
5
5
I-
6
6
7 8
7 8
9
9
GND
I+ GND TRIGGER INV ANLG CODE
DRY CONTACTS: MINIMUM CURRENT = 2mA OR LESS RATING CONTACT BOUNCE = 5mS OR LESS
Wiring Your Model 30 to a (Form A) Triggering Input
Model 30 Hardware Operations Manual
Page 40
3-6
Chapter 3
DEM - 9P P2 1 2
J2 1 2
3
3
4
4
V+
5
5
I-
6
6
7
7
8
8
9
9
12 - 24 VOLT DC NORMALLY OV OR OPEN
TRIGGER TRIGGER GND
I+ GND TRIGGER INV ANLG CODE
Wiring Your Model 30 to a (12-24 Volt) Triggering Input
74XX NORMALLY HIGH
DEM - 9P P2 1
J2 1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
TRIGGER TRIGGER GND V+ II+ GND TRIGGER INV ANLG CODE
MODEL 30 REPRESENTS APPROXIMATELY 2 TTL LOADS
Wiring Your Model 30 to a (TTL) Triggering Input
Accu-Sort Systems