For the Accu-Sort Model 20

Page 1

Model 20 Series II Bar Code Scanner OPERATIONS AND MAINTENANCE MANUAL

Revision: 2.2

Release Date: 12/02

Page 2

This page is a scan with no text; see it in the PDF.

Page 3

Product Addendum Model 20 Operations Manual Model 22 Operations Manual Date: 8/7/00 Filename: ecn4681_add.doc ECN: 4681 Writer: ERZ

Introduction This addendum documents an additional mounting option for your Model 20 and 22 laser scanners. This information supersedes any similar information in your manual.

Specifications This new mounting assembly p/n 100499 can be used to mount the Models 20 and 22 to any structure. It is shown below with a Model 10. To use the 100499 with a Model 20 an M26B is required. To use with a Model 22, a MDL22-8B is required.

Accu-Sort Systems

Addendum 1

Page 4

Addendum 2

Accu-Sort Systems

Page 5

I

INTRODUCTION This is the Operations and Maintenance Manual for the Model 20. It provides details on everything you need to know to unpack, set up, operate, and maintain your system. This note box is used throughout this manual to indicate supplementary information important to the current topic.

This document does not provide detailed information about any equipment used in or with this system that Accu-Sort Systems does not manufacture. This manual is not a troubleshooting or service procedure guide. Customers can purchase technical service training directly from Accu-Sort. Direct any questions about detailed troubleshooting or service to the Accu-Sort Systems Customer Service Department. MANUAL REVISIONS This Operations and Maintenance Manual is under revision control. Any addenda or other documents associated with this manual are under separate revision controls. A revision number is changed by 0.1 whenever technical information is changed or added to a document. Any revision less than 0.1 is automatically considered preliminary. Any document with a revision 1.0 or greater has been officially released by the Accu-Sort Systems ECN process. The document revision history can be found in the Revision History section at the end of this manual. DISCLAIMER Information in this manual is subject to change without notice. No part of this document is to be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, or by an information storage and retrieval system without the prior written consent of Accu-Sort Systems, inc. All drawings and specifications contained in this manual are the property of Accu-Sort Systems, inc. and shall not be reproduced, copied or used in whole or in part as the basis for the sale or manufacture of devices without written permission. Copyright© 2000 Accu-Sort Systems, inc. All Rights Reserved

Page 6

II

WARRANTY Accu-Sort Systems, inc. warrants that its scanner and component parts will be free from defects in material and workmanship for a period of one year from the date of shipment (15 months for distributors to account for stocking of units). All new replacement units will also be warranted for the remainder of the original one-year time period. Unless otherwise stated, warranty for products not manufactured by ASI is limited to the manufacturer’s warranty. Accu-Sort’s sole obligation with respect to damage (whether direct, incidental or consequential, resulting from the use or performance of the unit) is to replace the defective units thereof. Service requests due to misuse, abuse, neglect, changes in the original specifications, or service calls not related to the Accu-Sort equipment, will be charged at the then current service rate plus all travel related expenses. • If the unit fails within two weeks of shipping (Out Of Box Failure):

Standard units and custom units with only custom software are replaced within 48 hours with new units. Units with custom hardware will be replaced in 72 hours with new units. If the defective unit is not returned within 30 days, the customer will be contacted. If the defective unit is not returned after 45 days, the customer will be invoiced for that unit. Accu-Sort will issue an RA# (return authorization number) for each defective unit. • If the unit fails after two weeks of shipment, but before the end of the warranty period: These procedures are the same as Out Of Box Failures, except Accu-Sort will send refurbished units instead of new units. These refurbished units will be warranted for 90 days from date of shipment or the balance of the original oneyear warranty, whichever is greater. • If the unit fails after the original warranty period (Out Of Warranty

Failures): These procedures are the same as Out Of Box Failures, except Accu-Sort will send refurbished units instead of new units. These refurbished units will be warranted for 90 days from date of shipment. All out of warranty defective units will be replaced for a fixed price. Contact the Accu-Sort Customer Service Department for the current prices.

Additional details on the coverage, support, and services available for your bar code scanning and automated systems equipment is available from: 2800 Crystal Drive Hatfield, PA 19440

Accu-Sort Systems, inc. 511 School House Road Telford, PA 18969

2398 North Penn Road Hatfield, PA 19440

Phone: (215) 723-0981 1-800-BAR-CODE FAX: Telford Main ..........(215) 721-5551 Customer Service ...(215) 723-1515 Systems ..................(215) 996-8181 Sales .......................(215) 996-8282 Acct/Mktg ..............(215) 996-8249 TMS .......................(215) 996-8787 North Penn .............(215) 997-4848 Internet: www.accusort.com

Page 7

III

CUSTOMER SERVICE If you have any problems or questions that require Accu-Sort’s help, direct your calls to the Customer Service Department. Accu-Sort Customer Service: phone:

fax:

(215) 723-0981 1-800-BAR-CODE (ask for Customer Service) (215) 723-1515

To ensure that Accu-Sort’s response is prompt and accurate, please have the following information ready to give the Customer Service Department when calling: • Product Serial Number • Product Type or name • Detailed description of the question or problem • Customer contact name and phone number Product Type

Serial Number

Model 20 Serial Tag

Serial Number Breakdown: WWXXXXXX (YY...) WW - Two digit year of manufacture XXXXXX - Six digit sequential build number Y - Optional suffix(es) that reflect actual catalog options for the off-the shelf units Model 20 Suffix

Interface Box Suffix

A Standard B High Density C High Speed

A B

Without relays With relays

Add Ons Z ZR1 ZR2

Custom Custom 1@10 Raster Custom 1/2@10 Raster

- ex: M20A would have "A" as suffix - at least 6 digits can be placed on the tag - if "Z" is called out, this indicates a custom unit requiring folder - could be used for special designations The WWXXXXXX fields are bar coded with a Code 128 type bar code.

Page 8

IV

SAFETY RECOMMENDATIONS AND PRECAUTIONS The Model 20 is an electronic microprocessor-based imaging unit. Please follow the safety precautions and warnings found throughout this manual in order to prevent personal injury or damage to the unit. Failure to follow these precautions may void your warranty. The following note boxes are displayed throughout this manual to indicate safety concerns and/or warnings. This note box is used to provide precautions and/or guidelines, warning the user that personal injury or damage to the unit may occur during the task they are performing. This note box is used to alert the user they are about to perform an action involving a dangerous level of voltage, or to warn against an action that could cause electrical shock. Measures must be taken to prevent Electrostatic Discharge (ESD) at all times when the cover is off the Model 20. Circuit Boards are at the most risk. See Safety Recommendations and Precautions - Electrostatic Discharge.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

WHEN UNPACKING AND MOUNTING • Do not drop the unit • Do not touch the exit window glass WARNING This is a Class A product. In a domestic environment this product can cause radio interference in which case the user may be required to take adequate measures. (ref. CISPR 22 = EN 55 022:1995) WARNING In order to maintain Electromagnetic Compatibility (EMC) Compliance interconnecting cables must be connected using a 360° shield connection of all the interface cables with a conductive strain relief for RF shielding purposes (I.e.:'metalized' 'D' sub-strain relief). This applies to all I/O cables connected through 'D' sub-connectors. WARNING If for any reason your Model 20 does not work, do not attempt to open the unit. The Model 20 is designed to be returned to the factory for repair/replacement.

Page 9

V

GENERAL PRECAUTIONS Please follow these precautions: • Avoid staring at the laser beam. Staring at the laser beam for prolonged periods could result in eye damage. • Do not create any obstructions of airflow to the unit. Keep the area around the unit clean to provide for cooling. • Any service should be performed so as not to violate compliance with the Code of Federal Regulations, Title 21, Part 1040, Section 10 (21 CFR 1040.10), as administered by the Center for Devices and Radiological Health, a service of the Food and Drug Administration under the Department of Health and Human Services. Do not attempt to defeat any safety provisions. • Learn where the disconnect switches or circuit breakers are for your area. (Ensure that others using the equipment know this also.) • Use shielded interface cables with this product. To maintain FCC compliance, the cable shield must make a mating connector. • Before performing any type of maintenance, turn off power to the unit and disconnect the power source. • Be certain your hands and the floor of your work area are dry before touching electrical equipment or connecting cords. • Routinely check all connections to your Model 20. If a cable is damaged in any way, replace it. • Routinely examine all wiring and plugs for any signs of exposed wire or deteriorating insulation. • Check mounting hardware periodically for tightness and stability. • Do not use sheet rock or wood as a mounting surface for the Model 20. Use steel or aluminum as a mounting structure. LASER SAFETY To prevent possible exposure to laser light that may exceed the CDRH’s Accessible Emission Limit for a Class II laser, your Model 20 has a “Scanning Safeguard” feature which shuts off the laser power if the mirror wheel fails to rotate. This ensures that a stationary laser beam cannot exit the scan head. The following software command has been provided as an alternate to the beam attenuator. When <ESC><ESC><ESC> is sent to the scanner, it causes the unit to turn the laser off. The commands 1600 (save), 1602 (abort), or 1603 (use) will cause the laser to turn back on. The use of optical instruments with this product will increase eye hazard. Do not look into the laser beam with instruments such as telescopes, binoculars, or cameras. Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure.

Page 10

VI

GROUNDING THE MODEL 20 The system must be grounded electrically at all times. Please follow these precautions: • Ensure your AC power outlet has a properly grounded receptacle. • Make sure you have the appropriate power cord for your country before turning on the unit. • Do not turn on the system until all components are properly cabled and grounded with three-conductor AC power cords. Do not use a two-prong adapter. • Do not cut or remove the round grounding prong from the plug under any circumstances. • Do not use an extension cord to defeat the ground. ELECTROSTATIC DISCHARGE Electrostatic discharge (ESD), the transfer of static electricity from one object to another, is an often-unnoticeable hazard to electronic components. Boards and other devices with integrated circuits are particularly sensitive to ESD damage. Product failures may not occur until days or weeks after the component was damaged. Static damage to components can take the form of upset failures or catastrophic failures (direct and latent). An upset failure occurs when an electrostatic discharge is not significant enough to cause total failure, but may result in intermittent gate leakage, causing loss of software or incorrect storage of information. Direct catastrophic failures occur when a component is damaged to the point where it is permanently damaged. The following note box is displayed where ESD precautions must be followed: Measures must be taken to prevent Electrostatic Discharge (ESD) at all times when the cover is off the Model 20. Circuit Boards are at the most risk. See Safety Recommendations and Precautions - Electrostatic Discharge.

Five Basic Rules for ESD Control

Below are some keys to effectively control unnecessary ESD damage. When working with ESD-sensitive devices: • Define an ESD protective area and work on the ESD-sensitive devices in this area only; • Define the sensitivity of devices to be handled in the ESD protective area; • Establish a suitable static control program that both limits static generation to less than the damage threshold of the most sensitive device in the environment, and provides a safe, defined path for the dissipation of static charges; • Prevent contamination of the protective area by unnecessary non-static controlled materials; and • Audit the ESD protective area regularly to ensure that static control is maintained. Document the findings for future reference.