Page 51
START UP AND OPERATION
4-5
Mode 2 – Read Rate
Mode 2 Segment Values
In this mode, the Model 10 continually monitors the number of trigger cycles and good reads since the last boot sequence. The counters for Trigger and Good Reads are both 16 bits wide. For example:
The read rate is displayed below for the number of good reads compared to triggers.
Trigger
Good Reads
Read Rate (%)
1 2 3 4 65 143 685
1 2 3 4 64 138 665
100 100 100 100 98 96 97
Bar Graph Appearance
Update Frequency: End of every Trigger
Solutions with Vision
Page 52
4-6
MODEL 10 OPERATIONS AND MAINTENANCE MANUAL Mode 3 – Self-Test
Accu-Sort Diagnostic Code
This mode can be used to verify scanner operation by reading the Accu-Sort diagnostic code (ASIDiag01). To perform the test: 1. 2. 3. 4.
Save your settings. Unplug the Model from the host serial connection. Place the code in the beam path. Press the test button until C led is lit. All 5 LEDs will blink at a high rate of speed. 5. Press and hold the test button for approximately 1 second. All 5 LEDs will blink at a higher rate of speed. 6. The Model 10 attempts to read the code. If the code is read, the Model 10 dumps all three display screens (5000, 5001, 5003) at 9600 7E2, and then returns to normal operations. If the code is not read, or the button is not pressed and held, in 10 seconds, the scanner returns to normal operations. As the laser turns on the Model 10 reverts to the following settings: • 9600 baud • 7 data bits • Even parity • 2 stop bits
The following message is transmitted via both the RS485 and the RS232 interfaces: • Clear Bar Graph display • Dump of all Menus (use existing 5000, 5001, 5003 menu dumps)
There are two types of input are possible, Press And Release (PAR), and Press And Hold (PAH) PAR - Pushbutton switch is closed for a duration between 100ms and 3 seconds - Used to scroll through available Display Modes - The trailing edge of PAR (release of pushbutton) initiates action PAH - Pushbutton switch is closed for a duration greater than 3 seconds - Used to Reset Display Mode data to the Reset Value
Accu-Sort Systems
Page 53
START UP AND OPERATION
4-7
Bar Graph State
Description
Entered How?
Exited How? go to next mode
Display Data
Constantly updates the bar graph with current data corresponding to the current mode.
power on
(Stable state) Display Mode ID (Unstable state)
Normal default state. Single LED on (no blink) indicates the current Display Mode From Display Data State, 1st PAR trailing edge indicates current Mode (1 - 5). Additional PARs increment Mode and single LED scrolls through available Modes. (wraps from last to 1)
PAR
PAH during this Display Mode state will Reset Display Mode data of the current Mode to the Reset Value.
PAH never causes Mode to increment because PAR trailing edge never occurs. Without a PAR or PAH, the Model 10 returns to the Display Data state after a 3 second timeout.
Solutions with Vision
Page 54
4-8
MODEL 10 OPERATIONS AND MAINTENANCE MANUAL
START-UP TASKS Do not turn on the system until all components are properly cabled and grounded with three-conductor AC power cords. Do not use a two-prong adapter. Do not use an extension cord to defeat the ground. Ensure your AC power outlet has a properly grounded receptacle. Make sure you have the appropriate power cord for your country before powering the unit. Do NOT use the Model 10 power line to operate other equipment, especially induction motors and solenoids.
Prior to operating your Model 10 complete all of the following tasks: 1. Using the customer-specific specifications provided with your order, verify that the mounting distances, mounting angle, and product sensing signal device (photoeye) distances are correct. 2. Verify that all of the necessary connections have been made correctly and that the connected equipment is functioning properly. (Refer to Chapter Two). 3. Apply power to the Model 10. 4. Set up your software as described in the Accu-Setup Suite - Small Scanner Module Programming Manual.
Accu-Sort Systems
Page 55
Chapter Five Troubleshooting
5Heading 2
Chapter Five
Contents
TROUBLESHOOTING .................................................................................. 5-3 PRELIMINARY STEPS ............................................................................. 5-3 TROUBLESHOOTING TABLES.................................................................. 5-3
Page 56
5-2
Accu-Sort Systems
MODEL 10 OPERATIONS AND MAINTENANCE MANUAL
Page 57
TROUBLESHOOTING
5-3
TROUBLESHOOTING PRELIMINARY STEPS 1. Verify the power indicator is on steady, not blinking. 2. Verify that the Status LED is blinking green. 3. Verify that when trigger toggles, the trigger LED goes yellow following active trigger input. 4. Verify that when trigger input is active the laser is energized. The laser may be set to be on continuously.
5. Verify that when the laser is energized, the entire bar code is in the laser beam. This means that the entire bar code (either direction, first bar to last bar, or last bar to first bar) must be ’sliced’ by the laser beam. After verifying the above steps to be true, refer to the tables below. TROUBLESHOOTING TABLES The following series of tables will help you solve problems that may arise in your Model 10. The following table will help to guide you to the correct table/page for your problem: Table Problem 1 No power indication 2 Status LED blinks red 3 Status LED blinks yellow 4 Status LED blinks repeated red-green-yellow sequence 5 Input LED does not toggle 6 Model 10 will not decode 7 Model 10 will not communicate with Accu-Setup 8 Model 10 sends data but the host does not receive it
Page 5-4 5-4 5-4 5-4 5-5 5-5 5-6 5-6
Solutions with Vision
Page 58
5-4
1
MODEL 10 OPERATIONS AND MAINTENANCE MANUAL
No power indication
Possible Cause(s) A - Type of power input
Solution A - If using any interface box, verify (using the appropriate documentation that describes proper voltage and current requirements) that power is supplied to the interface box. If no interface box is being used, verify (using the appropriate documentation that describes proper voltage and current requirements) that power is supplied to the Model 10 and on the correct wires. If the correct power is being supplied, and the Model 10 does not power up, return the unit to Accu-Sort Systems, inc. for further repair.
2
Status LED blinks red
Possible Cause(s) A - Laser / Motor failure
3
Solution A - 1 - Connect the Model 10 to a PC running Accu-Setup (Small Scanner Setup). 2 - Establish a connection to the scanner (See Small Scanner Setup Instructions.) 3 - Select Utilities - Terminal Mode. It may be necessary to use the standard terminal interface, or if a button has already been defined, select Hwerr, or (<ESC><^B>3003<^M><ESC>). 4 - The HARDWARE / SOFTWARE STATS should be displayed. Look for the Laser/Motor failures. If either is greater than 0, call Accu-Sort Systems, inc. with the noted problem and return the unit for further repair.
Status LED blinks yellow
Possible Cause(s) A – Watchdog resets error
Solution A - 1 - Connect the Model 10 to a PC running Accu-Setup (Small Scanner Setup). 2 - Establish a connection to the scanner (See Small Scanner Setup Instructions.) 3 - Select Utilities - Terminal Mode. It may be necessary to use the standard terminal interface, or if a button has already been defined, select Hwerr, or (<ESC><^B>3003<^M><ESC>). 4 - The HARDWARE/SOFTWARE STATS should be displayed. Look for the Watchdog resets. If greater than 0, call Accu-Sort Systems, inc. with the noted problem and return the unit for further repair. NOTE - The Watchdog resets error is normally used to diagnose a software problem. It will be necessary to give as much detail about how this error occurs, such as scanning with excessive noise on the box, or any specific piece of nearby equipment starting/stopping).
4
Status LED blinks repeated red-green-yellow sequence
Possible Cause(s) A - Model 10 is in setup mode
Solution A – Return the Model 10 to run mode by cycling power -- or --
1 - Return the Model 10 to run mode by connecting the Model 10 to a PC running Accu-Setup (Small Scanner Setup). 2 - Establish a connection to the scanner (See Small Scanner Setup Instructions.) 3 - Select Exit Accu-Setup. 4 - If the scanner appears to go into the setup mode again, re-establish a connection to the scanner. Select Modify Setup - Port Setup. Ensure the Always allow setup mode box is not checked. This box allows the setup mode to be entered by the <ESC><ESC><ESC> sequence.
Accu-Sort Systems
Page 59
TROUBLESHOOTING
5
5-5
Input LED does not toggle
Possible Cause(s) A – Software currently not set up properly
Solution A - If using HARDWARE TRIGGER
1 - Connect the Model 10 to a PC running Accu-Setup (Small Scanner Setup). 2 - Establish a connection to the scanner (See Small Scanner Setup Instructions.) 3 - Select Modify Setup - Trigger Setup and ensure that Trigger Mode is set to Hardware trigger, and that the Trigger State is set correctly. Select OK on the Trigger Setup screen, then select OK on the Modify Setup screen. 4 - Select Utilities - Terminal Mode, and ensure that the unit is in the Run Mode. 5 - Attempt to trigger the unit using the hardware trigger device. If there is no transmission from the scanner, and the Input LED does not follow the trigger input, attempt to locate the triggering device. If the triggering device has any indication built into it, then attempt to trigger the device, and observe this built in indicator. If the indicator changes state with trigger, it may be necessary to troubleshoot the wiring. If this cannot be done on-site, call Accu-Sort Systems, inc. with the noted problem, and return the unit for further repair. - If using SERIAL TRIGGER
1 - Connect the Model 10 to a PC running Accu-Setup (Small Scanner Setup). 2 - Establish a connection to the scanner (See Small Scanner Setup Instructions.) 3 - Select Modify Setup - Trigger Setup and ensure that Trigger Mode is set to Serial trigger, and that the Character to start/end trigger is set correctly. Select OK on the Trigger Setup screen, then select Port Settings. Ensure that the Port settings match the port settings of the device being used to serially trigger the scanner. Select OK on the Port Settings screen, then Select Utilities - Terminal Mode, and ensure that the unit is in the Run Mode. 4 - Attempt to trigger the unit using the same serial characters selected in the Trigger Setup screen. If there is no transmission from the scanner, and the Input LED does not follow the trigger input call Accu-Sort Systems, inc. with the noted problem, and return the unit for further repair.
6
Model 10 will not decode
Possible Cause(s) A - Problems with bar code setup
Solution A - DETERMINE BAR CODE TYPE
1 - Connect the Model 10 to a PC running Accu-Setup (Small Scanner Setup). 2 - Establish a connection to the scanner (See Small Scanner Setup Instructions.) 3 - Select Diagnostic Mode - Learn Bar Code Type, and follow the instructions on the screen. If this diagnostic mode can determine which bar code was read, exit the diagnostic screen, and select Modify Setup - Bar Code Setup. Verify that the scanner is set up to read the correct bar code type. 4 - If the diagnostic mode cannot determine which bar code was read, it may be necessary to go to the Bar Code Setup screen and alternately enable every allowed bar code, and manually test the scanner to see which bar code is readable. If no bar code can be read, call Accu-Sort Systems, inc. with the noted problem, and return the unit for further repair. USE SCANS/100 BAR GRAPH INDICATION
1 - Once the scanner is verified to be set up to read the correct bar code type, return the scanner to the run mode, then enter the scans/100 mode. 2 - Make the trigger signal active to the scanner, and place the bar code in the laser line. 3 - Observe the bar graph display, and move the bar code in/out and side to side in the laser line slowly until the maximum readout is obtained on the bar graph display. It may be necessary to move the scanner so that it is reading the bar code in this area. 2 B - Exit Window is dirty or smudged
B - Clean Exit Window (see Maintenance Procedures, page 6-3)
C - Loose hardware connections
C - Check all hardware connections for tightness
Solutions with Vision
Page 60
5-6
7
MODEL 10 OPERATIONS AND MAINTENANCE MANUAL
Model 10 will not communicate with Accu-Setup
Possible Cause(s) A - Improper or faulty cabling
8
Solution A - 1 - Connect the Model 10 to a PC running Accu-Setup (Small Scanner Setup). 2 - Attempt to establish a connection to the scanner (See Small Scanner Setup Instructions.) 3 - If no communication can be established, observe the ’COM’ LED on the Model 10. When Accu-Setup is attempting to communicate with the Model 10, Accu-Setup will send the ’SETUP’ command to the Model 10, and the ’COM’ LED should show short red blips. If there are no red blips on the ’COM’ LED, there may be a problem with the communication cable, or the PC. If this problem is isolated to the Model 10 cabling, it may be necessary to call Accu-Sort Systems, inc. with the noted problem, and return the unit for further repair. 4 - If the LED is giving red blips, then there should also be green blips (Model 10 Response). If there are no green blips, verify that the unit is in setup by observing the ’STATUS’ LED blinking red/yellow/green. 5 - If the Model 10 is in setup, cycle power while connected to the PC running Accu-Setup. If the Model 10 again gets into setup, there is a problem with either the cabling or the PC, that is keeping the PC from receiving the response from the Model 10. If this problem is isolated to the Model 10 cabling, it may be necessary to call Accu-Sort Systems, inc. with the noted problem, and return the unit for further repair.
Model 10 sends data but the host does not receive it
Possible Cause(s) A - Model 10 currently not set up properly
Accu-Sort Systems
Solution A - 1 - Connect the Model 10 to a PC running Accu-Setup (Small Scanner Setup) 2 - Establish a connection to the scanner (See Small Scanner Setup Instructions.) 3 - Select Modify Setup - Port Setup/Advanced (if necessary). 4 - Verify that the scanner port settings match the host settings including Advanced settings. Not only is it necessary to have BAUD / PARITY / DATA / STOP / PROTOCOL / FLOW set up correctly, normally transmissions are in a packet format, TRANSMIT HEADER / DATA / TRANSMIT TRAILER. If this formatting is not set up correctly, the host will most likely not ’receive’ the data.