Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 10 of 11

Model 10 Bar Code Scanner Operations and Maintenance Manual, pages 91 to 100

Pages 91 to 100 of 102

The original document is the PDF (6.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Accu-Sort Model 10

Page 91

GLOSSARY

11

Parameter

A value or opinion that you specify to a program. A parameter is sometimes called a switch or an argument. Parity Bit

A bit that is set at “0” or “1” in a character to ensure that the total number of 1 bits in the data field is even or odd. Percent good reads

The number of successful reads per refresh period. This is valid only when the refresh period is set to 0. Performance indicator

A bar code decoder function that counts the number of decodes during a trigger period. When the period = 0, the performance indicator provides the number of decodes (up to 100 attempts). Use the performance indicator to provide a general indication of bar code symbol quality or verify proper setup of the scanner. Performance indicator limit

A set point that will produce a discrete output if the performance indicator falls below the set point value. Pen Scanner

A pen-like device either connected by wire to a device, or self-contained, used to read bar codes. Requires direct contact with the symbol. Peripheral Device

An internal or external device, such as a printer, a disk drive, or a keyboard, connected to a computer. Photoeye

Used as a presence detector to identify objects in the scanner’s reading zone. The photoeye emits a beam and is used with a reflector to create a photoelectric circuit. When the beam is blocked by an object, breaking the circuit, a signal called CART is sent to the scanner. Picket Fence Orientation

When the bar code’s bars are positioned vertically on the product, causing them to appear as a picket fence. The first bar will enter the scan window first.

Pitch

Rotation of a code pattern about the X-axis. The normal distance between center line or adjacent characters. Polarized Laser

A specialized laser source used in high glare environments. Polling

A means of controlling devices on a multipoint line. Protocol

A formal set of conventions governing the formatting and relative timing of message exchange between two communicating systems. Pulse Width

A change from the leading edge of a bar or space to the trailing edge of a bar or space over time. Pulse width is also referred to as a transition. Queue

A buffer used to hold data in order until it is used or transmitted. Quiet Zone

Required distance before the first bar and after the last bar of the code that must be free of marks or printing.

Solutions with Vision

Page 92

12 Radio Frequency

Non-optical automatic identification devices that use radio waves to transmit data. Raster

The process of projecting the laser beam at varied angles spaced evenly from each other. Typically, the mirror wheel surfaces are angled to create multiple scan lines instead of a single beam. Raster Mirror Wheel

The standard mirror wheel forms the laser line that is projected from the scanner. Although the mirror wheel projects 8 separate lines (for an 8-sided mirror wheel), the speed of the sweep makes it appear that it is actually one line. This type of mirror wheel is adequate for a ladder orientation because the laser line will pass from the bottom to the top of the code. For a picket fence orientation the standard mirror wheel is not always adequate. One problem facing the picket fence orientation is that the same portion of the code is being repeatedly scanned. If the printing quality at this point is not good the label may not be scanned even though other parts of the label are good. Another problem for a picket fence orientation is the placement of the label. If the placement is off enough a single scan line will not read all the bar codes presented to the scanner. Read-only

A read-only file is one that you are prohibited from editing or deleting. A file can have read-only status if: • Its read-only attribute is enabled. • It resides on a physically write-protected diskette. • It is located on a network in a directory to which the system administrator has assigned read-only rights to you. Read Zone

Area in front of the scanner’s window in which the bar code should appear for scanning. This zone consists of the scan window and the raster width (if used). Reflectance

The amount of light returned from an illuminated surface. Relay

Relays are simply electrical switches that are typically used to control external diverts, alarms, etc. Relay types available are FORM A and FORM C. FORM C type relays have both normally open and normally closed contacts available while FORM A type relays have only normally open contacts available. Relay Output Duration

This is the time (in seconds) after the relay is energized that it should be turned off. Relay Output Delay

The time lapse between an event and the energizing of the relay. Request To Send (RTS)

An RS232 modem interface signal which indicates that the DTE has data to transmit. Resolution

The narrowest element dimension which can be distinguished by a particular reading device or printed with a particular device or method. Response Time

The elapsed time between the generation of the last character of a message at a terminal and the receipt of the first character of the reply. It includes terminal delay and network delay. ROM

The acronym for read-only memory. The computer contains programs essential to its operation in ROM. A ROM chip retains its contents even after you turn off your computer. RPM

The abbreviation for revolutions per minute. RS-232

Interface between data terminal equipment and data communication equipment employing serial binary data interchange. RS422

The Electronic Industries Association standard that specifies the electrical characteristics of balanced voltage digital interface circuits. RS485

The Electronic Industries Association standard that specifies the electrical characters of generators and receivers for use in balanced digital multipoint systems.

Accu-Sort Systems

Page 93

GLOSSARY

13

Scan

A single pass of the laser beam over the code or a portion of the code. The search for a bar code symbol that is to be optically recognized. Scan Area

The area intended to contain a symbol. Scan Window

The usable length of the scanning beam that may detect the bar codes. The scan window is perpendicular to the depth of field. Scanner

An electronic device that optically converts printed information into electrical signals. These signals are sent to the decoder logic. Scanner Orientation

Relationship of the scan head with reference to the bar code’s location on products. The scan head must be set up to insure that all code bars and spaces are bisected at the same time. Typically, either side read or top read is used for picket fence or ladder code orientations. SCSI

The acronym for small computer system interface. An I/O but interface with faster data transmission rates than standard ports. The user can connect up to seven devices to one SCSI interface. Self-checking

A bar code or symbol using a checking algorithm which can be independently applied to each character to guard against undetected errors. Sensor

A device that detects or measures something and generates a corresponding electrical signal to an input circuit of a controller. Serial Port

An I/O port used most often to connect a modem or a mouse to your computer, identifiable by its 9-pin connector. Serial Transmission

The most common transmission mode; serial, information bits are sent sequentially on a single data channel. Serial Asynchronous Transmission Of Data

The following are common communications interfaces: RS232, RS422, RS485, 20mA current loop and RS423. When data is transmitted serially from a communications port, the information is transferred between the two devices one data bit at a time. The data flow can follow one of three different communications modes: simplex, half duplex, or full duplex. Each character of data within the data flow is transported in a binary bit frame called the asynchronous data frame. The start bit begins each frame. A low voltage signal on the data communications line marks the beginning of the start bit, at which point the receiving device begins looking for binary zeros and ones (0’s and 1’s).The following five to eight data bits (the number depends on the format used) comprise the binary character. For error detection, an optional parity bit can define whether the total number of zeros or ones was even or odd. There are five different parity selections as shown below: ODD last data bit is a logical 0 if the total number of logical 1’s in the first seven data bits is odd. EVEN last data bit is a logical 0 if the total number of logical 1’s in the first seven data bits is even. MARK last data bit is always a logical 1 (i.e.: high/mark). SPACE last data bit is always a logical 0 (i.e.: low/space). OFF (NONE) last data bit is not present. The method used to catch errors by using parity bits is as follows: When the transmitter frames a character, it tallies the number of 0’s and 1’s within the frame and attaches a parity bit. (The parity bit varies according to whether the total is even or odd.) The

Solutions with Vision

Page 94

14 receiving end then counts the 0’s and 1’s and compares the total to the odd or even recorded by the parity bit. If a discrepancy is noticed by the receiving end, it can flag the error and request a retransmission of the data. A stop bit is used to signal the end of the character. (Stop bits are typically one or two bits in length. The slower the transmission speed, the more stop bits required for recognition of the end of the data frame.) In addition to the direction of data flow and the data framing, there are other considerations to insure uniform transmissions. Certain operating parameters must be followed to prevent the loss of valuable data. The first consideration is the speed of transmission, known as baud rate. Serial data transmission is measured in bits per second (BPS). The baud rate selections typically available are: 110, 300, 1200, 2400, 4800, 9600 and 19200. To enable two devices to interact, they must both be transmitting/receiving data at the same baud rate. If it is not possible to do this, there must be a buffer (typically additional storage memory) that accommodates the differences in communications speed. Many serial communications links also use a flow control system to handle data transmission in addition to memory buffers. X-ON/X-OFF Protocol A common type of flow control is the X-ON/X-OFF protocol. When a receive buffer nears its memory capacity, the receiving device sends an ASCII X-OFF signal to the transmitting device, telling it to stop sending data. When the memory buffer has enough space to handle more data, the X-ON signal is sent to the transmitting device, telling it to start sending data again. ACK/NAK Protocol Another common protocol is ACK/NAK protocol. When the device transmits a message to the host, the host responds with either an ACK (06H) or a NAK (15H). If the host transmits an ACK to the device, the device deletes its transmit message and the communication sequence is complete. If the host transmits a NAK, the device will retransmit. The device resends data a maximum of three times. Optionally this may be changed to 1, 2, 3, or infinite retransmits by the user. If the device receives a fourth NAK, it will delete the data in its transmit buffer and display “MAX REXMITS”. A transmitting device ignores ACK and NAK characters received during data transmission. If, for example, a device receives a NAK during a data transmission, it will not resend the data at the completion of the transmission. The device also has a retransmit timer. This timer is activated each time the device transmits data to the host. If the timer runs for two seconds (this is also changeable) and the device does not receive an ACK or NAK from the host, a timeout occurs and the device retransmits its data. Each time the device retransmits because of a timeout, it treats the timeout the same as receiving a NAK from the host computer. If the device does not receive an ACK before the end of the fourth timeout, it will delete the data in its transmit buffer and display “MAX REXMITS”. The device deletes data in its transmit buffer and displays the error message when any combination of four timeouts and NAKs from the host occurs. When the device receives a message from the host, it calculates the BCC for the message and compares the calculated BCC to the received BCC. If the two values match, the device transmits an ACK, ending the communication. If the values do not match, the device transmits a NAK to the host and waits for the host to retransmit the message. The host, like the device, should retransmit a maximum of three times. The sequence number starts at zero (30H) and is incremented each time a device transmits a new message. When the sequence number reaches nine (39H), it wraps around to one (31H). If the sequence number skips a number, the receiving device knows that a message was lost. If the same sequence number is received on two sequential messages, the second message is responded to with an ACK or NAK (as appropriate) and ignored. Shielding

Protective covering that eliminates electromagnetic and radio frequency interference. Side Read

The scanner is mounted to read the side of a box as it passes by the head. Signal

An impulse or fluctuating electrical quantity (i.e.: a voltage or current) the variations of which represent changes in information. Skew

Rotation about the Y-axis. Rotational deviation from correct horizontal and vertical orientation; may apply to single character, line or entire encoded item. Space

The lighter elements of a bar code symbol formed by the background between bars.

Accu-Sort Systems

Page 95

GLOSSARY

15

Specular Reflections

A condition when the laser light is reflected back from the code’s surface at an angle equal, or nearly equal, to the angle of incidence of the laser light. This condition makes it difficult for the scan head to detect the differences in light variation caused by the code’s bars and spaces. Spot

The undesirable presence of an area of low reflectance in a space. start and stop characters Stacked Codes

16K and Code 49 are examples where a long symbol is broken into sections and "stacked" one upon another similar to sentences in a paragraph. Extremely compact codes. Start Bit

In asynchronous transmission, the first bit or element in each character, normally a space, that prepares the receiving equipment for the reception and registration of the character. Stop Bit

The last bit in an asynchronous transmission, used to indicate the end of a character, normally a mark condition, that serves to return the line to its idle or rest state. STX (Start of Text)

A transmission control character that precedes a text and is used to terminate a heading. (^B) Symbol

A combination of characters including start/stop and checksum characters, as required, that form a complete scannable bar code. Symbologies

Code 39 A bar code with a full alphanumeric character set, a unique start and stop character, and three other characters. The name is derived from its code structure, which is 3 wide elements out of a total of 9 elements. The nine elements consist of five bars and four spaces. Code 128 A bar code symbology capable of encoding the full ASCII 128 character set. It encodes these characters using fewer code elements per character resulting in a more compact code. It features a unique start and stop character for bidirectional and variable length decoding, both bar and space character parity for character integrity, a check character for symbol integrity, a function character for symbol linking, and spare function characters for unique application definition and/or future expansion. Interleaved 2 of 5 (I 2of5) A bar code with a numeric character set with different start and stop characters. The name is derived from the method used to encode two characters. In the symbol, two characters are paired together using bars to represent the first character and the spaces to represent the second. This interleaved structure allows information to be encoded in both the bars and the spaces. A start character, bar and space arrangement, at one end, and a different stop character bar and space arrangement at the other end, provide for bidirectional decoding of this symbol. Syntax

The rules dictating how you must type a command or instruction so the computer will understand it. System.ini file

When you start Windows, it consults the system.ini file to determine a variety of options for the Windows operating environment. Among other things, the system.ini file records which video, mouse, and keyboard drivers are installed for Windows. Running the Control Panel or Windows Setup program may change options in the system.ini file. Tag

A collection of information associated with a single variable or I/O point. Two-width symbology

A bar code symbology whose bar and spaces are characterized simply as wide or narrow. Codabar, Code 39, and Interleaved 2 of 5 are examples of two-width symbologies. Terminal Program

Computer software that sends, receives, and displays serial data. Thermal Printing

Thermal printers use heated print heads and special heat activated paper. There are two types of thermal printers. One uses a method similar to the dot matrix printer where an array of heated dots move along the paper and form the character or bar code.

Solutions with Vision

Page 96

16 The other method uses a heated bar and the paper moves across the bar. Another type of thermal printer is called a Thermal Transfer printer. The main difference between this type of printer and a thermal printer is the use of heat sensitive ribbons as opposed to heat sensitive paper. This type of printing is permanent on label stock. Common Problems with thermal printing Since the paper used is heat activated the labels will deteriorate over time in a warm environment. Infrared scanners cannot detect the bar codes and consequently a visible red light laser must be used to scan these codes. Benefits of thermal printing Thermal printers are quiet and inexpensive. Thermal Transfer

A printing system like thermal except a one-time ribbon is used and common paper is used as a substrate. Eliminates the problems of fading or changing color inherent in thermal printing. Tilt

Rotation around the Z axis. Used to describe the position of the bar code with respect to the laser scan line. Trigger

(Also known as cart) A signal, typically provided by a photoeye or proximity switch, that informs the scan head of the presence of an object within its reading zone. UCC (Uniform Code Council)

The organization which administers the UPC and other retail standards. Undersquare

Used to describe bar codes that are longer (from the first to last bar) than they are high (from the top to bottom of the bars). UPC

Acronym for Universal Product Code. The standard bar code type for retail food packaging in the United States. UPS

The abbreviation for uninterruptible power supply. A battery-powered unit that automatically supplies power to your computer in the event of an electrical failure. Utility

A program used to manage system resources including memory, disk drives, and printers. Vane Raster

Decreases the amount of scans possible due to a smaller percentage of scans bisecting the code. Verifier

A device that makes measurements of the bars, spaces, quiet zones and optical characteristics of a symbol to determine if the symbol meets the requirements of a specification or standard. Vibrating Vane

A variable raster that can have an unlimited number of raster lines. It covers a larger area and is adjustable. Visible Laser Diode

A light source used in scanners to illuminate the bar code symbol. Generates visible red light at wavelengths between 660 and 700 nM. Replaced Helium-Neon tubes in most scanners because they are small and consume less power. Void

The undesirable presence of an area of high reflectance in a bar. Wand Scanner

A hand-held contact laser scanner that an operator guides across the bar code. Wedge

A device that plugs in between a keyboard and a terminal. It allows data to be entered either by keyboard or by various types of scanners. Wide Bar (WB)/Wide Space (WS)

Widest code element, bar or space, in the bar code symbol.

Accu-Sort Systems

Page 97

GLOSSARY

17

Wide to Narrow Ratio

Dividing the size of the wide elements by the size of the narrow elements of a bar code yields the bar and space ratios. Bar and space ratios can differ. NOTE: If the narrow bar and narrow space are equal and the wide bar and wide space are equal then you calculate only one ratio. Window

A display area that the users interacts with to operate a tool. Word

A unit of data which contains two bytes (16 bits). Write-protected

Read-only files are said to be write-protected. You can write-protect a 3.5-inch diskette by sliding its write-protect tab to the open position and a 5.25-inch diskette by placing an adhesive label over its write-protect notch. "X" Dimension

The dimension of the narrowest bar and narrowest space in a bar code. XON

A control character sent by the receiving device to signal the transmitting device to begin sending data. XOFF

A control character sent by the receiving device to signal the transmitting device to stop sending data.

Solutions with Vision

Page 98

18

Accu-Sort Systems

Page 99

Index Index

A Accu-Sort Diagnostic Code .............................................4-6 Application Examples Automated Blood Analyzer.........................................7-5 Bar Code Verification .................................................7-3 Label Printing Verification .........................................7-3 PC Board Tracking......................................................7-4 Product Counting ........................................................7-4 Product Identification..................................................7-5 ASCII Communications ASCII Chart ...............................................................A-9 Protocols Used With RS232, Current Loop, and 422.A-8 Standard RS485 Multidrop Communications.............A-3 ASCII Digit, RS485 Communications ...........................A-3 Automated Blood Analyzer .............................................7-5

B Back Read .....................................................................3-15 Ball and Socket Mount Dimensions ...............................................................3-10 Kit ...............................................................................1-5 Mounting Procedure..................................................3-11 Parts List ...................................................................3-10 Terms ........................................................................3-11 Bar Code Verification......................................................7-3 Bar Graph Display Description..................................................................4-3 Mode 1 – Scan Efficiency ...........................................4-4 Mode 2 – Read Rate....................................................4-5 Mode 3 – Self-Test......................................................4-6 Block Diagram of System................................................1-9 Bottom Label...................................................................1-9

C Cable Pin Configurations ................................................2-3 Checking Connections for Tightness...............................6-3 Checking the Packing Slip...............................................1-3 Connections.....................................................................2-3 Contact Points, Mounting................................................3-5 Customer Service...............................................................iii

D Damaged Equipment .......................................................1-3 DeviceNet........................................................................1-6 Dimensions, Model 10...................................................1-10 Disclaimer ...........................................................................i Display Panel Bar Graph Display ......................................................4-3 Description..................................................................4-3 Display Mode Descriptions.........................................4-4 LEDs ...........................................................................4-3 Document Reproduction......................................................i

E EM-50............................................................................. 2-4 Error Recovery, RS485 Communications ...................... A-6 Ethernet........................................................................... 1-6 Examples, Mounting..................................................... 3-13 Exit Window Cleaning ..................................................................... 6-3 Mounting Requirements ............................................. 3-4 Exterior Cleaning............................................................ 6-3 External Display.............................................................. 1-5

F FAX Numbers.................................................................... ii FCC Compliance.................................................................v Features Basic ........................................................................... 1-7 Performance.............................................................. 1-10 Physical .................................................................... 1-10

G General Description of System Operation....................... 1-7 General Precautions ............................................................v General Rules, RS485 Communications........................ A-6

H HEX Digit, RS485 Communications ............................. A-3 Hexadecimal & Decimal Character ASCII Table .......... A-9

I Installation ...................................................................... 3-3 Internet Address................................................................. ii Introduction......................................................................... i

L Label Locations................................................................. vi Label Printing Verification ............................................. 7-3 Lamp Enclosure .............................................................. 1-5 LEDs ............................................................................... 4-3

M Maintenance Tasks.......................................................... 6-3 Making Connections ....................................................... 2-3 Manual Revisions ............................................................... i Master Device ................................................................ A-3 Master/Slave Timing Diagram....................................... A-5 Message Formats, RS485 Communications................... A-4 Message Sequencing, RS485 Communications ............. A-5 Missing Equipment ......................................................... 1-3 Model Configuration....................................................... 1-9

Page 100

2

MODEL 10 OPERATIONS AND MAINTENANCE MANUAL

Mounting Ball and Socket Mount..............................................3-10 Contact Points .............................................................3-5 Examples...................................................................3-13 Mounting Column .......................................................3-6 Mounting Kit...............................................................1-5 Mounting Structure Assembly.....................................1-5 Multipurpose Mounting Bracket ......................... 3-6, 3-7 Repeatability ...............................................................3-5 Screw Selection...........................................................3-4 Universal Mounting Bracket .......................................3-9 Universal Mounting Shipkit................................ 3-8, 3-9 Multidrop Protocol Examples, RS485 Communications A-7 Multipurpose Mounting Bracket.............................. 3-6, 3-7

Retroreflective Pair ......................................................... 2-4 RS485 Communications Description ................................................................ A-3 Error Recovery .......................................................... A-6 Example..................................................................... A-3 Master Device............................................................ A-3 Master/Slave Timing Diagram................................... A-5 Message Formats ....................................................... A-4 Multidrop Protocol Examples.................................... A-7 Poll Messages ............................................................ A-3 Slave Device.............................................................. A-3 Time Limits ............................................................... A-6

N NEMA Rating..................................................................6-3

O Object-Sensing Signal Device .........................................2-4 Optical Setup .................................................................1-12

P Parts Table.......................................................................1-6 PC Board Tracking..........................................................7-4 Phone Numbers ..................................................................ii Photoeye Object-Sensing Signal Device.....................................2-4 Photoeye Kit................................................................1-4 Pin Configurations...........................................................2-3 Poll Messages, Master/Slave ..........................................A-3 Power Connection Example ...................................................3-3 Power Supply ..............................................................1-4 Precautions ........................................................................iv Product Counting.............................................................7-4 Product Identification ......................................................7-5 Product Specifications ...................................................1-10 Protocols Used With RS232, Current Loop, and 422 .....A-8

R Read Charts General Purpose ........................................................1-12 High Density .............................................................1-13 Repeatability, Mounting ..................................................3-5 Requirements Installation ..................................................................3-3 Mounting.....................................................................3-4

S Safety Recommendations and Precautions........................ iv Scanner Expansion Module ..................................... 1-4, 2-4 Screw Selection, Mounting ............................................. 3-4 Serial Tag.......................................................................... iii Side Read ...................................................................... 3-13 Slave Device .................................................................. A-3 Small Scanner Interface ........................................... 1-4, 2-4 Specifications, Model 10 .............................................. 1-10 Start-Up Tasks ................................................................ 4-8

T Time Limits, RS485 Communications........................... A-6 Timing Diagram, Master/Slave ...................................... A-5 Timing, RS485 Communications................................... A-5 Top Read....................................................................... 3-14 Troubleshooting Preliminary Steps........................................................ 5-3 Tables ......................................................................... 5-3 Typical Applications....................................................... 1-7 Typical Installation Embedded................................................................... 1-8 Material Handling....................................................... 1-8

U Universal Mounting Bracket ........................................... 3-9 Universal Mounting Shipkit..............................1-5, 3-8, 3-9

V Ventilation ...................................................................... 3-4

W Wiring and Terminating Connections ............................. 2-3