Accu-Sort's two-page specification sheet (version 1.0, July 1999) for the Model EM-50 Scanner Expansion Module. The EM-50 is an interface box that powers an Accu-Sort Model 10, 20 or 22 scanner and adds parallel outputs, serial pass-through and optional fieldbus links. The sheet gives its outputs, connectors, power, size and environmental specifications.
- Device
- Scanner expansion module (interface box) for Accu-Sort scanners; can power Models 10, 20 and 22 p. 1
- Parallel outputs
- 2 standard NPN/PNP selectable outputs (NPN 60V/140mA max., PNP 30V 200mA max.); 2 optional solid state relays up to 240 VAC/3A p. 2
- Communications
- Serial port pass-through from scanner: RS-232, RS-422, RS-485 multidrop; service port for scanner programming and diagnostics p. 2
- Fieldbus options
- DeviceNet, Profibus and Ethernet p. 1, 2
- Power
- 15-30VDC standard, overvoltage and reverse polarity protected; 100-240VAC 50/60Hz optional p. 2
- Power draw
- 5 Watts plus the attached scanner p. 2
- Connectors
- Service port D connector; spring-actuated terminal blocks for power input, trigger/tach input, serial port and parallel outputs p. 2
- Diagnostics
- Power, Trigger and Status LEDs, visible through the lid p. 1, 2
- Enclosure
- NEMA 4 (IP 65) cast aluminum, watertight cable glands p. 1, 2
- Size and weight
- 5.8 x 4.3 x 3.0 in. (148 x 108 x 76 mm); 2 lbs (0.9 kg) p. 2
- Temperature range
- 32°-122°F (0°-50°C) p. 2
- Relative humidity
- 10%-95% non-condensing p. 2
- Other options
- Keyswitch (for scanner matchcode learn or custom functions), beeper, remote display p. 2
What this sheet walks you through
- Connecting Accu-Sort scanners to DeviceNet, Profibus or Ethernet p. 1
- Powering the attached scanner from DC or the optional AC supply p. 1
- Programming and monitoring a Model 10, 20 or 22 through the service port p. 1
Good to know
- Specifications may change without notice. p. 2
- The sheet states that UL, FCC and CE approvals were pending. p. 2
Questions this sheet answers
What scanners does the Accu-Sort EM-50 work with?
The sheet names the Accu-Sort Models 10, 20 and 22, which the EM-50 can power and connect to for programming. p. 1
What voltage does the EM-50 need?
15-30VDC as standard, or 100-240VAC 50/60Hz with the optional internal AC supply; it draws 5 W plus the scanner. p. 2
Does the EM-50 support Profibus or DeviceNet?
Yes, as options, along with Ethernet. p. 2
What outputs does the EM-50 have?
Two NPN/PNP selectable parallel outputs as standard, with two optional solid state relays rated up to 240 VAC/3A. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Model
EM-50
Scanner Expansion Module
Accu-Sort’s newest scanner interface offers many interface options. The EM-50 offers a great variety of parallel outputs, making it directly compatible with a wide range of industrial equipment. Fieldbus options are available, enabling you to attach Accu-Sort scanners to the increasingly popular buses such as DeviceNet and Profibus. The integral DC-DC converter has a wide voltage input range, allowing the EM-50 (and the scanner attached to it) to be powered by commonly available DC power. When AC power is required, the optional AC power supply installs in the same enclosure, eliminating the need for separate mounting. The EM-50 can be used to power Models 10, 20 and 22. The EM-50 is packaged in a compact, rugged, NEMA 4 rated cast-aluminum enclosure. All connections to the unit are through watertight cable glands.
Terminations are made via quick-connect terminal blocks, facilitating installation and updates. Diagnostic LEDs are visible through windows on the lid of the unit, and a beeper and keyswitch are optional.
Scanner Expansion Module
ACCU-SORT®
OUTSTANDING BENEFITS
The EM-50 comes standard with two NPN/PNP selectable parallel outputs for interfacing with most common industrial inputs. Optional solid state relays are available for high voltage/high current applications. A programming/monitor port simplifies connection to our Model 10, 20 and 22 during programming, and also can be used to monitor real-time communications. Available options include: Integral AC power supply, multiple output relay configurations, keyswitch, beeper, remote display, and the following fieldbus support:
- DeviceNet
- Profibus
- Ethernet
The EM-50’s broad I/O capability lets it interface directly with most industrial devices; spring actuated terminal blocks allow for quick connections
Fieldbus availability allows EM-50 to “drop in” to existing fieldbus systems
Integral DC-DC converter uses commonly available DC power
NEMA 4 cast aluminum enclosure withstands the toughest industrial environments
Solutions with vision
Accu-Sort® Systems, inc. • 511 School House Road • Telford • PA • 18969
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
EM-50 - Interior
Product Speci f ications Parallel Outputs: 2 Standard NPN/PNP selectable outputs: NPN -60V/140mA max. PNP - 30V200mA max. 2 Optional solid state relays, up to 240 VAC/3A Visual Diagnostics: Power, Trigger, Status LEDs Connectors: Service port “D” connector Spring-actuated terminal blocks for: Power input Trigger/tach input Serial port Parallel outputs Size: Length - 5.8” (148 mm) Width - 4.3” (108 mm) Height - 3.0” (76 mm)
Weight: 2 lbs (0.9 kg)
Temperature Range: 32°-122°F (0°-50°C)
Relative Humidity: 10%-95% non-condensing
Enclosure: NEMA 4 (IP 65)
Power: 15-30VDC standard, overvoltage and reverse polarity protected 100-240VAC 50/60Hz (optional) 5 Watts + Power consumption of attached scanner
Communications: Service port for scanner programming/diagnostics Serial port pass-through from scanner RS-232 RS-422 RS-485 Multidrop Options: Keyswitch (for scanner matchcode learn or other custom functions) Beeper Remote Display DeviceNet, Profibus, and Ethernet connectivity Safety approvals (pending): UL, FCC, CE Warranty: 1-year limited, parts and labor
Accu-Sort reserves the right to change specifications without notice
Accu-Sort® Systems, inc. • 511 School House Road • Telford • PA • 18969 800-BAR-CODE • 215-723-0981 • fax 215-996-8249 • info@accusort.com • http://www.accusort.com
ver. 1.0 7/99