For the Accu-Sort AL5010
Page 41
To mount the Basic Interface Module: 1. Position the basic interface module in the desired mounting position. (Position the cord grips so they are face down or to the side.) 2. Using a Phillips screw driver, attach with the supplied mounting hardware.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 42
To mount the Enhanced Interface Module: 1. Position the basic interface module in the desired mounting position. (Position the cord grips so they are face down or to the side.) 2. Using a Phillips screw driver, attach with the supplied mounting hardware.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 43
Mounting the I/O Modules
I/O MODULE APPLICATIONS OUTPUT MODULES Activate diverter/sorter for no read, multi-read, match, or no match conditions. Activate device (e.g., beacon light) to indicate any of the above conditions. Activate device for use as a “life condition’ indicator. Activate device to follow the trigger condition. Activate alarm. INPUT MODULES Additional photoeye input for Start/End Trigger NOTE: The following input module applications require custom software. Transmit photoeye Divert Accomplished photoeye Reboot signal
The Enhanced Interface Module supports four (4) optional input or output modules that can be used for trigger inputs or to operate diverters, alarms, etc. The optional I/O modules are not installed at the factory.
I/O Module Location in Enhanced Interface Module
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 44
36
AccuLazr™ AL5010 Product Line Manuals
Mechanical Installation
To install your optional I/O module(s): 1. Remove the cover to gain access to the printed circuit board. 2. The I/O modules may be plugged into locations I/O 1 through I/O 4. These locations run left-to-right, as shown on the circuit board silkscreen. 3. Plug the appropriate I/O module directly into the interface module’s circuit board. 4. Using a screwdriver, secure the I/O module by tightening the captive screw (that goes through the module) into the circuit board. DO NOT over-tighten screw.
Installing an I/O Module
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 45
!""#$%&'()!$*+,+)-'./#"0)$123)4%2#%5! !
"#$%&'(%)#!*+,&)##)&(-+! !
6!))753"0'1"%5)8290%55%01.2)
:!;<8<=>!"#$%&'(%)#!*+,&)##)&(-+!./!01)#(2($3!4$'5(%$!6$%7+(%()+,! 8+#/9!0$1$')#!2'-%$34'$,!(+1-#1$!$52-,4'$!&-!1-#&)6$!(+,(3$!&7$!(+&$'8)%$! 9-34#$:!;!&')(+$3!&$%7+(%()+!94,&!2$'8-'9!&7$,$!2'-%$34'$,:!<-!+-&! )&&$92&!&-!2$'8-'9!)+=!$#$%&'(%)#!(+,&)##)&(-+!2'-%$34'$,!4+#$,,!=-4!)'$!)! &')(+$3!&$%7+(%()+:!
!
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
! !
-'3'3A#191039) P$8-'$!9-4+&(+6!)+=!%-92-+$+&,K!2#$),$!3-!&7$!8-##-J(+6Q! !! F$)3!)##!(+,&'4%&(-+,!C$8-'$!C$6(++(+6!=-4'!(+,&)##)&(-+:!! !! <$8(+$!)+3!%-+8('9!&7$!)%%4')%=!-8!=-4'!)22#(%)&(-+L,!'$R4('$9$+&,:!! !! *'+,'-!&#'!.&$/0$(0!'1'2&(,2$1!-,(,/3!0($-,/3.!%(4+,0'0!,/!5%%'/0,6!78! !! F$1($J!)##!(+,&)##)&(-+S,2$%(8(%!3')J(+6,:!! !! F$1($J!)+3!2#)+!&7$!2-J$'!'$R4('$9$+&,!8-'!=-4'!)22#(%)&(-+:! !! F$1($J!)+3!2#)+!&7$!%-994+(%)&(-+,!'$R4('$9$+&,!8-'!=-4'!)22#(%)&(-+:! !
@..59);3A#1'3/))) !! !! !! !! !! !
M7(##(2,!0%'$J!<'(1$'!DTBH! E#)&!U$)3!0%'$J!<'(1$'!D,9)##H! V('$!W4&&$',! V('$!0&'(22$',! >$$3#$S+-,$!M#($',!
!//101.2%5)82B.'C%01.2) 0$$!)#,-Q!8),-9%:#;#$#'-#%<),2#*!8-'!*+,&)##)&(-+! !! ;?@ABA!J(&7!P),(%!*+&$'8)%$!X-34#$!DBAAAA/AY@ZH! !! ;?@ABA!J(&7!"+7)+%$3!*+&$'8)%$!X-34#$!DBAAAA/AY@/H! !! ",&)C#(,7(+6!;!W-++$%&(-+!&-!&7$!G,$'!*+&$'8)%$!DBAAAA/AY@[H! !! \$&&(+6!0&)'&$3!J(&7!&7$!G,$'!*+&$'8)%$!DBAAAA/AY@]H!
!
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
./!
Page 46
Installation Sequence(s) NOTE: Everything should be MECHANICALLY INSTALLED before performing any ELECTRICAL INSTALLATION. See Chapter 3 for mechanical installation details. Installing a Single Unit To install a single unit, follow this sequence of steps: Complete mechanical installation. See Chapter 3. Complete electrical installation. Ground the mounting structure to protective earth (PE) ground. Connect AL5010 reader to interface module (two connections). Connect Ethernet network to interface module. Connect the power supply to interface module. Connect trigger to interface module. Connect tachometer to interface module (Enhanced Interface Module Only). Connect serial communications to interface module. Connect wiring for I/O module(s) to interface module (Enhanced Interface Module Only). Install Fieldbus if needed- DeviceNet or Profibus (Enhanced Interface Module Only). Attach scan head to mounting base. NOTE: To reduce the possibility of damage to the scan head, install it after the interface module is mounted, wired, and all wiring is checked for accuracy. Be sure to perform the polarity check before attaching the scan head.
Setup your AL5010. See Chapter 5. Check operations. See Chapter 6.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 47
Installing Multiple Readers For electrical installation, multiple-reader networks will require a different approach to wiring, since the trigger photoeye and tachometer are most likely being shared by the group of readers. (See drawing 113492 in Appendix F.) Special instructions for functional set-up of a multi-reader network are provided in Chapters 5 and 6. NOTE: If Tracking, Fieldbus and/or I/O Modules are not needed, an Enhanced Interface Module is not required.
Multiple Readers with EtherNet Communications
Multiple Readers with Serial Communications
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 48
Multiple Readers with a Single Interface Module
General Electrical Installation Guidelines and Precautions It is important that you follow these general precautions when installing, setting up, operating, maintaining, troubleshooting or replacing any Accu-Sort products, parts or related equipment. CAUTION: The AL5010 use lasers for bar code scanning. Do not view directly with optical instruments (binoculars or telescopes). Avoid unintentional exposure to laser light whenever possible. As you plan and install your AL5010 bar code solution application, be sure to keep the following guidelines in mind: Determine the reader is in the proper orientation and position as outlined in Chapter 3. Leave adequate clearances (approximately 8-12 inches [203.2304.8mm]) for wiring. The interface modules have several cord grip openings. Seal unused openings with rubber grommet plugs (units ship with rubber plugs in place). Remove the grommet plugs when inserting cables. Use cord grips with rubber grommets on cables that enter the interface module. Route wires carefully to reduce or minimize electrical noise. The interface modules are designed so power and communication wiring should not need to cross. WARNING: To assure no ESD damage will occur, be sure to observe the precautions outlined in Chapter 2, Safety.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 49
Cable and Cord Grip Connections Determine the wiring connections needed for your application. All permanent connections are made to the basic or enhanced interface module with either cables or through cord grips. Be sure to follow Accu-Sort’s wiring recommendations. Wiring Recommendations Connection
Recommended Wiring Type
Safety Earth Ground
For 15-20 Amp branch circuit, use #18 AWG min. For 16-25 Amp branch circuit, use #14 AWG min. For 26-32 Amp branch circuit, use #12 AWG min. #20 AWG minimum #24 AWG minimum #24 AWG minimum #24 AWG CAT5 UTP (unshielded twisted pair) #24 AWG minimum Depends upon module rating. See Appendix A.
Power RS232 RS422 Ethernet Tach / Trigger I/O Modules
Max. Length
50’ [15.2] 1000’ [300] 330’ [100]
NOTE: ALL external wiring must be UL listed or recognized rated VW-1 or FT-1 and conforming to NEC ANSI/NFPA 70. Cord Grips
Recommended Wiring Diameters
Small Diameter Large Diameter
Accommodates 0.138 to 0.276 inches (3.5 to 7.0 mm) Accommodates 0.177 to 0.394 inches (4.5 to 10.0 mm)
Cable Connections to Interface Module
Where the cabling enters the interface module, use the supplied cord grips with rubber grommets. Once all cabling is completed, plug all unused interface module openings.
IMPORTANT: All unused openings must be plugged to maintain the Interface Module’s IP54 rating.
Proper Wiring to Terminal Blocks inside Interface Modules 1. If necessary, strip the insulation off the end of wire approximately 1/4” [6,35mm]. 2. Use flathead screwdriver to push the spring-cage terminal block open until it stops. 3. Insert wire into terminal opening. 4. Allow the screwdriver to release the spring-cage terminal block. 5. Confirm the wire is held firmly in place.
Wiring the AL5010 Interface Modules After completing mechanical installation, use this section to properly wire your AL5010 reader for optimal performance in your application. All wiring connections are made via a basic or enhanced interface module. Use the conduit openings for running wires into the interface module. Route your cabling for power, tachometer, trigger, communications, and I/O through the recommended conduit openings.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 50
Basic Interface Module
Basic Interface Module Wiring tables, printed on the interface module, help simplify installation.
Basic Interface Module Terminal Block Locations See also: Drawing 113491 in Appendix F.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net