13. In Modify Settings > Raster, gradually increment your upper and lower sweep values toward 0%. Try 5% increments first, i.e.: Set both the Upper Sweep and Lower Sweep to -15, then -10, -5, 0, 5, and etc. The laser should intersect a barcode at each degree setting.
14. Check the read quality on the monitor at each increment. The quality should be 100%. 15. Continue incrementing the upper and lower sweep settings until the scan line reaches or goes just beyond the level of the highest barcode.
16. In Modify Settings > Raster, set the lower sweep at -20 and the upper sweep to the value determined in step 15.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 32
17. Click Update, and then click the Save icon ( ) at the top of the user interface screen. The laser will begin to sweep between your lowest and highest barcode indicators.
0.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 33
Run Test Labels 1. Configure the scanner for your application by setting up communications, barcode types, triggers and relays as applicable to your system (See Chapter 5 Setup). 2. In the user interface, navigate to Diagnostics > Monitor. 3. Place a test barcode at the front edge of the box in the lowest position and run the box through the system.
4. Check the Monitor screen to see how the barcode reads. The quality will likely not be 100%, but it is just important that it reads. 5. Next, place the test barcode at the front edge of the box in the highest position and run the box through the system.
6. Again, check the Monitor screen to make sure the barcode has been read.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 34
7. Continue checking for good reads by placing the label at the back edge of the box, once in the lowest position and then at the highest position.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 35
Dimensions and Clearances The overall dimensions of the AL5010 when the Universal Mounting Bracket (UMB) is used are shown on the mechanical specification drawings provided in the drawings folder of the documentation CD. This section also includes drawings without the UMB. The reader is a sealed, unventilated unit. No specific clearance is required for the purpose of cooling. However, ease-of-access should be considered when locating the mounting position. NOTE: For installation, maintenance and service reasons, approximately 8-12 inches [203-305 mm] of clearance is recommended.
Attaching the Mounting Base If your application is not using the universal mounting bracket (UMB), mount the mounting base to any flat surface with the two mounting screws provided. The length of the screws must not be greater than 0.5 inch [12.7 mm] plus the thickness of the mounting surface. Use the following diagram as a reference to create a mounting template.
Mounting Base Dimensions (not actual size)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 36
Attaching the Universal Mounting Bracket (UMB) The Universal Mounting Bracket (UMB) is an optional accessory that simplifies reader mounting and installation. Included with the bracket is the necessary hardware to attach it to the mounting structure. 1. When using this option in your application, follow the assembly instructions provided with the universal-mounting bracket (UMB). 2. Attach the UMB to the mounting structure with the provided hardware. 3. Attach the mounting base to the UMB. Use the two screws provided with the mounting base. 4. Insert the screws through the UMB into the threaded holes on bottom of mounting base. 5. DO NOT over-tighten screws. Leave the screws slightly loose to allow for some movement in the mounting base so that final adjustment of the reader in relation to scanning area can be made after wiring is completed.
Attaching Mounting Base to Universal Mounting Bracket (UMB)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 37
Installing an AL5010 Scan Head Perform the electrical installation as outlined in Chapter 4. Once all wiring is checked for accuracy, install the AL5010 scan head to the mounting base. You can install the scan head with or without the power disconnected from the mounting base. To install a scan head: 1. Carefully align the scan head (1) alignment tabs to the mounting base. This automatically assures the correct scan head-to-mounting base connector alignment. 2. Gently, press the scan head down until it firmly connects with the connector in the mounting base (2). 3. Tighten the two captive screws to secure the scan head to the base. Do not over tighten. 4. Adjust the UMB so the reader’s laser exit window faces the approximate location of where the bar-coded packages will appear.
AL5010 Scan Head Installation on Mounting Base
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 38
Mounting the Trigger Photoeye The standard photoeye works by bouncing a light beam off a reflector and detecting when something breaks the path of light. In order for photoeyes to work properly, make sure the following things are done when mounting the trigger photoeye option:
Mount trigger and reflector so the reader’s scan beam does not strike either of them. Mount a reflector directly opposite the photoeye on the other side of the conveyor. Install the reflector within the operating range of the trigger photoeye. The photoeye must be mounted so the light exit window is perpendicular to the conveyor, facing the reflector. The reflector must be mounted perpendicular to the conveyor, facing the photoeye. Secure the photoeye and reflector to the mounting brackets with the hardware provided. IMPORTANT: The trigger photoeye’s beam (between photoeye and reflector) must be blocked by a package before the barcode is in position for scanning. The trigger signal should remain active while the symbol is being scanned. This does NOT apply to tracking applications.
NOTE: The Trigger Photoeye can also be used in a Start/End Trigger application as the Start Trigger Photoeye. In this instance, an End Trigger Photoeye Kit (with DC input module) is also required. An End Trigger photoeye can only be used with an Enhanced Interface Module.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 39
Mounting the Tachometer The tachometer (tach) option outputs a set number of pulses for each wheel rotation. This tells the AL5010 the precise conveyor speed, allowing it to determine accurate package position. Tracking allows for multiple boxes to be in the scanning area at the same time. Barcodes on each box are decoded and assigned to the correct box. Follow the guidelines below:
Mount the anti-static brush to the tachometer as shown in the drawing provided with the tach. The anti-static brush provided with the tach must be installed to assure proper operation. Mount the tach on the conveyor section where scanning is performed. Mount the tach on the underside of the conveyor, away from areas where the conveyor bows downward. A good place to mount the tach is on one end of the conveyor, underneath the drive shaft. Make sure the tach assembly angles in the same direction that the underside of the conveyor travels. The tach must make good contact with the conveyor. Use the general mounting kit provided with your system to make tachometer mounting and setup easier.
Tachometer Mounting (anti-static brush not shown)
Tachometer with Anti-Static Brush Installed
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 40
Mounting the Interface Modules Mechanical installation sequence for AL5010 with either the Basic or Enhanced Interface Module: 1. Determine the location of the scanning system at the installation site. 2. Erect the mounting frame or other supporting structures. 3. Mark the mounting locations for each: a. AL5010 Reader b. Basic or Enhanced Interface Module 4. Attach the Universal Mounting Bracket(s) (UMB) to the frame. (UMB and mounting frame options are available from Accu-Sort.) 5. Attach the AL5010 Mounting Base to the UMB (or frame, if UMB not used). 6. Mount the Basic or Enhanced Interface Module. (See below.) 7. Mount the Accu-Sort power supply. 8. Mount the Trigger Photoeye (optional). 9. Mount the Tachometer (optional).
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net