Introduction
SECTION 1
8.
1 .l Product Overview The Plum A+TM Volumetric Infusion System is designed to meet the fluid delivery requirements of today’s evolving healthcare environments. The Plum A+ is a cassette based, two lines in and one line out, multifunction infusion pump. The pump can be used for standard, piggyback. 05 concurrent delivery. Therapy modes include: . Standard Infusions l
Multistep Programming
Loading Dose l Dose Calculation l
The Plum A+ is designed to deliver parenteral and enteral or epidural infusions over a broad range of infusion rates from multiple fluid container types. The system includes a pumping module (hereafter called the pump) and an assortment of disposable IV sets (hereafter called a set), optional accessories, and this operator’s manual. The optional Barcode Reader allows drug name identification by scanning a provided list of drug names located on the Flash Tips & Barcode Directory. A computer data port is also provided to interface with a host computer. The Plum A+ is designed to be used in most areas of patient care, including, but not limited to:
General Floor MedicallSurgical ICU/CCU Pediatrics Neonatolgy
Laborj3etiverylPost Pattum ORfinesthesia Post OpDecovery Cardiac Cath Lab Emergency l- 1
Burn Unit Hkmodialysis Oncology Mobile Intensive Cure Nutritional
430-95226-001 (Rev. 5/01)
Page 6
Introduction
1.2 Conventions This section describes the conventions used throughout this manual, as follows: Convention
Application
Example
Italic
Reference to a section, figure, or table
(See Figure 3- 1, Priming Cassette)
Function or mode specific instructions
Primary On/y: Attach an empty container.
[ALL CAPS]
Keys or touchswitches on the device are described all caps in brackets
[START]
A [Italic]
Softkey Options
A [Choose]
Initial Caps lowercase
Screen displays and device labels (as appropriate)
Therapy
I
I
Dose Calculation . ..sets are supplied Sterile and are for....
Emphasis
Bold
‘.
WARNINGS. CAUTIONS, AND NOTES Alert messages used throughout this manual are described below. Pay particular attention to these messages.
WARNING A WARNING MESSAGE CONTAINS SPECIAL SAFETY EMPHASIS AND MUST BE OBSERVED AT ALL TIMES. FAILURE TO OBSERVE A WARNING MESSAGE IS POTENTIALLY LIFE THREATENING. CAUTION: A CAUTION USUALLY APPEARS IN FRONT OF A PROCEDURE OR STATEMENT. IT CONTAINS INF-ORMATION TRAT COULD PRBVENT IRREVERSIBLE PRODUCT DAMAGE OR RARDWARE FAILURE. FAXLXJRE TO OBSERVE A CAUTION COULD RESULT M SERIOUS PATIENT OR USER INJURY. Note:
a
A Note highlights information that helps explain a concept or procedure.
This symbol directs the user to consult accompanying documents.
1.
Note: Figures are rendered as graphic representations to approximate the actual product. Therefore, figures may not exactly reflect the product.
430-95226-001 (Rev. 5/01)
l- 2
Plum A+ Infusion Pump
Page 7
Definitions (General and Clinical)
1.3 Definitions (General and Clinical) Alarms Backprime Bolus Cassette Installed Concurrent Delivery Delfvery Together Delivery Rate Duration Error Flow Rate KVO (Keep Vein Open) Line A Line B Malfunction Pfgg ybac k PressurelPost Infusion Rate Units VTBI Warning
Any condition of the pump that requires operator.attentfon. These condftions will cause both audible and visible alarm indicators. Confirmation of the condition is usuallu reauired. Removal of air orfluid from the proximal line and cassette air trap. Nofluid is delivered distal to the cassette during backpriming. A single uninterrupted discrete volume of jlufd delivered in a discrete period of time. A recognized cassette type installed with the door closed. Simultaneous delivery of twofluids at fndependentjlow rates.
Delivery option which allows lines A and B to deliver concurrently. The Delivery rate set by the operator. The time period used to deliver a VTBI at a delivery rate set by the operator. A condition resulting when an operator attempts a nonacceptable input, such as an invalid key press. The resulting rate of fluidflow. Delivery of fluid at a slow rate in or&r to prevent occluding the patient catheter. Cassette Inlet line on the top center of the cassette when looking at the cassette from the front of the Device. Cassette Inlet line on the top right of the cassette when looking at the cassette from the front of the Device. Failure of the device to pass internal integrity or performance tests. The mode where line B delivers first, followed by line A. Selected using A [OptfonslVol Inflt this mode is used to set KVO Rate and Dfstal Pressure Limit. It is also used to view Distal Pressure in real-time. A predetermined delivery quantity adopted as a standard of measure. Volume To Be Infused - The amount offlufd remaining to be delivered to the vatfent. An indication to advise the operator: a) Of a possibly hazardous condition such as a Low-Battery warning. b) That an attempt has been made to use a function in the wrong sequence, with the wrong values, or at the wrong time such as an Invalid Key Warning. c) That a function has been initiated in the proper manner such as a Valid Keu Warnfnq.
System Operating Manual l- 3