The user guide for the Zebra LP 2824, a direct-thermal desktop printer for labels and tags. It covers unpacking and inspecting the printer, attaching power, loading roll media, the power switch, feed button and status light, media length sensing, connecting by USB, parallel, internal Ethernet or serial, adjusting print width and quality, peel-mode, fan-fold media and the cutter option, cleaning, replacing the platen and print head, troubleshooting, calibration, and interface pinouts.
Its parts
- Introduction
- Getting Started
- Operation & Options
- Maintenance
- Troubleshooting
From the manual
Key facts from this manual
Each line names its page in the PDF.
The Zebra LP 2824 Desktop Printer User Guide (part 980481-001 Rev. A) for the direct-thermal label and tag printer. It covers loading roll and fan-fold media, connecting the printer by USB, parallel, Ethernet or serial, the peel-off and cutter options, cleaning, status light meanings, troubleshooting and connector pinouts.
- Device
- On-demand desktop printer for labels and tags, direct-thermal printing only p. 9
- Interface options
- One of three combinations: parallel; USB and DB-9 serial; or Ethernet and RJ-11 serial p. 22
- Serial defaults
- 9600 baud, no parity, 8 data bits, 1 stop bit; printer acts as DCE p. 25, 52
- USB
- Universal Serial Bus version 1.1 p. 23
- Parallel
- Centronics 36-pin connector on the printer; IEEE 1284-compliant cable recommended p. 23, 50
- Ethernet
- Internal ZebraNet PrintServer II, RJ-45 straight-through cable; rear test button prints a configuration label p. 23, 51
- Serial connectors
- DB-9 serial port (straight-through cable with DB-9P male end); optional 6-pin RJ-11 alternative serial port p. 23
- Accessory power
- DB-9 pin 1: +5 volts at 150 mA for an external device such as a KDU or scanner; RJ-11: +5 volts at 160 mA max p. 52, 53
- Power
- External DC power supply with barrel connector into the rear receptacle, plus a separate AC power cord p. 16
- Printing modes
- Standard tear-off; optional peel-off, liner-free (special platen only) and cutter p. 15
- Media
- Direct thermal media, usually on rolls; fan-fold or other continuous media also usable p. 15, 17
- Printer languages
- EPL2 page mode and EPL1 line mode p. 14, 45
- Cleaning supplies
- Cleaning pens (12), cleaning swabs (25), 2-in cleaning cards (25), 2-in Save-a-Print Head film (3) p. 33
- Data cables
- Fully shielded with metal or metalized connector shells; 6' (1.83 m) recommended p. 22
What this manual walks you through
- Loading roll media and setting the roll holders and guides p. 17, 18, 19
- Running media length sensing and printing a status printout p. 21
- Connecting the printer to a computer by USB, parallel, Ethernet or serial p. 22, 23, 24
- Changing the serial settings with the Y command p. 25
- Printing in peel-mode with the optional dispenser p. 29
- Printing on fan-fold media and using the cutter option p. 30, 31
- Cleaning the print head, media path and platen p. 33, 34, 35
- Reading the status light and solving print and media problems p. 41, 42, 43, 44
- Switching between line mode and page mode p. 45
- Manual calibration, factory defaults and communications diagnostics p. 46, 47
Good to know
- Only direct thermal media can be used. p. 17
- Use the power supply that came with the printer, and never operate either where they can get wet. p. 16
- No lubricants of any kind should be used on the printer. p. 35
- FCC Class B compliance assumes fully shielded six-foot data cables; longer or unshielded cables may exceed the limits. p. 22
- If labels run out while printing, leave the power on while reloading, or data is lost. p. 28
Questions this manual answers
What are the default serial port settings of the Zebra LP 2824?
9600 baud, no parity, 8 data bits and 1 stop bit. p. 25
Does the LP 2824 have USB or Ethernet?
It comes with one of three interface sets: parallel only, USB plus DB-9 serial, or Ethernet plus RJ-11 serial. p. 22
How do I calibrate the Zebra LP 2824?
With media loaded and power off, hold the feed button while turning the printer on, release it when the status light flashes, then press feed to leave dump mode. p. 46
How do I reset the LP 2824 to factory defaults?
Send the ^default command, which overwrites all stored parameters. p. 47
My LP 2824 prints programming codes instead of labels. What do I do?
Print a status report to see if line mode is active, then switch to page mode with the <ESC>EPL2 command or the feed button procedure. p. 45