The text of a manual · part 1 of 3
User's Manual for ZB-2200A Series, pages 1 to 8
Pages 1 to 8 of 23
The original document is the PDF (142 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Zebex ZB-2200AM
Page 1
IMPORTANT NOTICE
USER'S MANUAL FOR
ZB-2200A SERIES
ZEBEX INDUSTRIES INC. MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. ZEBEX INDUSTRIES INC. SHALL NOT BE LIABLE FOR ERRORS CONTAINED HEREIN OR FOR INCIDENTAL CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS MATERIALS. Copyright 1992, 1993, 1994,1995 by
ZEBEX INDUSTRIES INC.
ZB-1200R/ 2200R RS- 232C SERIAL INTERFACE ZB-1200K/ 2200K KEYBOARD EMULATION INTERFACE
IBM is a registered trade mark of International Business Machines Corp. IBM PC/XT is a product of International Business Machines Corp. IBM PC/AT is a product of International Business Machines Corp. IBM PS/2 is a product of International Business Machines Corp. NEC is a registered trade mark of NEC Corporation. All other registered trade marks are registered companys' property. ZEBEX is a registered trade mark of ZEBEX INDUSTRIES INC.
All rights reserved, reproduction of this document or any portion of its contents is not allowed without the specific written consent of ZEBEX INDUSTRIES INC. Every effort is made to ensure the accuracy of our product information; however, we accept no responsibility for errors or omission. Specification or version may be subject to change without notice. The actual specification and version are based on the product delivered.
PRINTED IN DECEMBER 1995
Page 2
IMPORTANT NOTICE
USER'S MANUAL Every effort is made to ensure the accuracy of our product information; however, we accept no responsibility for errors or omission. Specification or version may be subject to change without notice. The actual specification and version are based on the product delivered.
The manual can be used as keyboard emulation, RS- 232C serial interface, and CMOS serial interface. PRINTED IN DECEMBER 1995
Page 3
TABLE OF CONTENTS Introduction .................................................. 1 Programming Options ................................... 1 Default Parameters ........................................ 2 Program Procedure........................................ 5 Reset Scanner To Default Parameters ............ 6 Scanning Mode Selection .............................. 6 Header And Trailer ....................................... 6 Inter- Message Delay..................................... 7 Inter- Character Delay................................... 7 Message/ Block Mode Selection .................... 8 Block Mode Communication ......................... 8 Beeper Tone Selection................................... 8 RS-232C Serial Communication Parameters Setting........................................................... 9 Handshaking Protocol ........................... 9 ACK/ NAK Response Time Setting....... 9 Baud Rate ........................................... 10 Data Bit .............................................. 10 Stop Bit............................................... 11 Parity .................................................. 11 Message Suffix.................................... 11 Bar Code Identifier Code Setting................. 12 Keyboard Emulation Parameter Setting ....... 13 Keyboard Language Selection ............. 13 Keyboard Type Selection..................... 14 Message Suffix.................................... 15 Reading Code Selection............................... 15 Code 39 Parameters Setting......................... 17 Italian Pharmac Parameters Setting ............. 18 Interleaved 2 Of 5 Parameters Setting.......... 18 Post 2 Of 5 Parameters Setting .................... 19 Standard 2 Of 5 Parameters Setting............. 20 UPC/ EAN/ JAN Parameters Setting ........... 20 Codabar/ Monarch Parameters Setting......... 23
Page 4
Code 128 Parameters Setting....................... 24 Bar Code Length Setting ............................. 24 Capital Lock Setting.................................... 25 Show Version.............................................. 25 ISBN Code Setting ...................................... 25 ISSN Code Setting ...................................... 25 Appendix A Code 39 Full ASCII Code Table .......... 26 Appendix B Code 39 Full ASCII Bar Code Table ... 28 Appendix C Function Key Emulation...................... 37
INTRODUCTION The series CCD scanners can be configured by scanning a series of programming bar code labels. This allows the decoding option and interface protocols to be tailored to a specific application. The configuration is stored in non-volatile memory and cannot be changed by removing power from the scanner. The scanner must be properly powered before programming. For RS- 232C type scanners, an external power adaptor must be used to supply DC power to the scanner. If a keyboard emulation type scanner is used with a IBM PC/ XT/ AT, PS/ 2 or any fully compatible computer, power will be drawn from the keyboard port. No external power adaptor is required. If a keyboard emulation scanner is used with any other non IBM PC compatible computers, an external power adaptor may be needed. During programming mode, the CCD scanner will acknowledge a good and valid reading with a short beep. It will give two long beeps for either an invalid or bad reading.
PROGRAMMING OPTIONS Programmable options are divided into four groups. The first group includes the options that show the general behavior of the CCD scanner. The second group of options governs the operation of RS-232C type serial ports. The third group selects the keyboard type that the keyboard emulation scanner will emulated. The last group sets the decoding parameters for each bar code symbology.
Page 5
1 DEFAULT PARAMETERS
2 DEFAULT VALUES OF RS- 232C SERIAL COMMUNICATION PARAMETERS
This table gives the default settings of all the programmable parameters. The default settings will be restored whenever the "Reset" programming label is scanned and the CCD scanner is in programming mode.
DEFAULT VALUES OF OPERATING PARAMETERS
Function
Default Values
Scanning Mode Selection Header And Trailer Inter-Message Delay Inter-Character Delay Message/Block Mode Selection Send Command In Block Mode Communication Good Read Beeper Tone Selection Data Terminator
Trigger Mode None None None Message Carriage Return 1KHz/ 60 mSec Enter/ Carriage Return
DEFAULT VALUES OF KEYBOARD EMULATION PARAMETERS
Function
Default Values
Key Board Type Selection
IBM PC/AT USA Enter/ Carriage Return
Message Suffix
Function
Default Values
Handshaking Protocol ACK/NAK Response Time Setting Baud Rate Data Bit Stop Bit Parity Message Suffix Selection
None None
Code Identifier Transmitting Code 39 Bar Code Identifier Code ITF 2 of 5 Bar Code Identifier Code STD 2 of 5 Bar Code Identifier Code UPC-E Bar Code Identifier Code UPC-A Bar Code Identifier Code EAN-13 Bar Code Identifier Code EAN-8 Bar Code Identifier Code Codabar Bar Code Identifier Code Code 128 Bar Code Identifier Code Code 93 Bar Code Identifier Code Post 2 Of 5 Bar Code Identifier Code
9600 8 1 Mark (None) Carriage Return Disable M I H E A F FF N K L O
Page 6
3
DEFAULT VALUES OF DECODING PARAMETERS Function
Default Value
Code 128
Code 39 ITF 2 of 5 STD 2 of 5 UPC/EAN/JAN Codabar Code 128 Code 93 Post 2 of 5 (Option) Italian Pharmac Codes Start/ Stop Character Check Digit Concatenation Length Check Digit Length Check Digit Format Addendum UPC-E= UPC-A UPC-A= EAN-13 UPC-A Leading Digit UPC-A Check Digit UPC-E Leading Digit UPC-E Check Digit EAN-13 Check Digit EAN-8 Check Digit Start/ Stop Character FNC 2 Concatenation Check Digit
Post 2 of 5
Length Check Digit
Italian Pharmac
Transmit "A"
Reading Codes Selection
Code 39
Interleaved 2 of 5 STD 2 of 5
UPC/EAN/JAN
Codabar
PROGRAM PROCEDURE USING BAR CODE MENUS
Enable Enable Enable Enable Enable Enable Disable Disable Disable Standard Not Transmit Disable Disable 10 Digits Fixed Disable 10 Digits Fixed Disable All Disable Disable Disable Transmit Transmit Not Transmit Not Transmit Transmit Transmit A,B,C,D Disable Calculate But Not Transmit 11 Digits Fixed Calculate and Transmit Disable
START
Read Start of Configuration Label
Set All Defaults
Set Operating Parameters
Set Serial Port Parameters
No Finish Yes Read End of Configuration Label
END
5 4
Set Set Keyboard Decoding Type Parameters
Page 7
Start of Configuration • The reading of this code turns all the parameters back to default values. •
When you intend to return your scanner to the default parameters, scan the "RESET" label first. Do not scan "Start of Configuration"!
Set
INTER-MESSAGE DELAY
Enable Disable
RESET SCANNING MODE SELECTION
100 mSec
500 mSec Trigger Mode
Auto Scan Mode
1 Second INTER- CHARACTER DELAY
Repeat Mode None Alternate Mode 10 mSec
Monentary Mode Testing Mode
20 mSec
HEADER AND TRAILER 50 mSec 250 mSec
Header Trailer
End of Configuration
6 7
Page 8
Start of Configuration
Disable
MESSAGE/ BLOCK MODE SELECTION
RS- 232C SERIAL COMMUNICATION PARAMETERS SETTING HANDSHAKING PROTOCOL
Block None Message
SEND COMMAND IN BLOCK MODE COMMUNICATION
RTS/ CTS ACK/ NAK
Store Xon/ Xoff Set
ACK/NAK RESPONSE TIME SETTING
GOOD READ BEEPER TONE SELECTION 100 mSec 2 KHz/ 60 mSec
2 Sec 1 KHz/ 60 mSec
200 mSec 3 Sec
2 KHz/ 120 mSec 1 KHz/ 120 mSec
300 mSec 5 Sec
2 KHz/ 200 mSec 1 KHz/ 200 mSec 8
End of Configuration 9