The text of a manual · part 1 of 3
User's Manual: Handheld laser scanner & High performance Long Rang Dual CCD scanner, pages 1 to 10
Pages 1 to 10 of 30
The original document is the PDF (212 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Zebex Alpha-70
Page 1
LASER LIGHT
CAUTION
DO NOT STARE INTO BEAM 670nm LASER DIODE,1.0mW MAX OUTPUT IEC 825-1(1993)CLASS I,US 21 CFR 1040 CLASS IIa LASER PRODUCT
ZBX99030301 P/N : MUL-53221-04
Page 2
USER'S MANUAL
Handheld laser scanner & High performance Long Rang Dual CCD scanner
Alpha-50 series: Laser scanner Alpha-60 series: Laser scanner Alpha-70 series: Long Rang scanner
The manual can be used as keyboard emulation, RS- 232C serial interface, CMOS serial interface and wand emulation. HEADQUARTERS ZEBEX INDUSTRIES INC. Mobile Computer Division 2F, 531-1, Chung-Cheng Road, Hsin-Tien City, Taipei, Taiwan, R.O.C. Tel. +886-2-2218-2018 Fax.+886-2-2218-8670 Web site: www.zebex.com.tw E-mail: mail@zebex.com.tw
ZEBEX INDUSTRIES INC. Auto ID Division 1F, 531, Chung-Cheng Road, Hsin-Tien City, Taipei, Taiwan, R.O.C. Tel. +886-2-2218-3501 Fax.+886-2-2218-1415 Web site: www.zebex.com.tw E-mail: mail@zebex.com.tw
USA ZEBEX AMERICA INC. Ilene Court, Building 11, Unit 4, Belle Mead, New Jersey 08502, USA Tel. +1-908-359-2070 Fax.+1-908-359-1272 Web site: www.zebex.com E-mail: sales@zebex.com
GERMANY Z E B E X Vertriebs-GmbH Stimpelwiese 2, 61250 Usingen, Germany Tel. +49-1805-258443 Fax.+49-1805-258442 Web site:www.zebex.com.tw E-mail: zbg@zebex.com.tw
Page 3
IMPORTANT NOTICE ZEBEX INDUSTRIES INC. MAKES NO WARRANTY WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. ZEBEX INDUSTRIES INC. SHALL NOT BE LIABLE FOR ERRORS CONTAINED HEREIN OR FOR INCIDENTAL CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS MATERIALS.
USER'S MANUAL
Copyright 1999 by
ZEBEX INDUSTRIES INC.
IBM is a registered trade mark of International Business Machines Corp. IBM PC/XT is a product of International Business Machines Corp. IBM PC/AT is a product of International Business Machines Corp. IBM PS/2 is a product of International Business Machines Corp. NEC is a registered trade mark of NEC Corporation. All other registered trade marks are registered companys' property. ZEBEX is a registered trade mark of ZEBEX INDUSTRIES INC.
All rights reserved, reproduction of this document or any portion of its contents is not allowed without the specific written consent of ZEBEX INDUSTRIES INC.
Every effort is mode to ensure the accuracy jof our product information; however, we accept no responsibility for errors or omissions. Specification or version may be subject to change without notice. The actual specification and version are based on the product delivered.
The manual can be used as keyboard emulation, RS- 232C serial interface, CMOS serial interface and wand emulation.
PRINTED IN MARCH 1999
Page 4
IMPORTANT NOTICE
Every effort is mode to ensure the accuracy jof our product information; however, we accept no responsibility for errors or omissions. Specification or version may be subject to change without notice. The actual specification and version are based on the product delivered.
PRINTED IN MARCH 1999
TABLE OF CONTENTS Introduction .........................................................1 Default Parameters .............................................2 Program Procedure .............................................5 System Setting....................................................6 Scanning Mode Selection ....................................7 Header and Trailer ..............................................8 Inter- Message Delay ..........................................8 Inter- Character Delay .........................................9 Message/ Block Mode Selection ..........................9 Beeper Tone Selection ......................................10 Bar Code ID Selection ....................................... 11 RS-232C Serial Communication Parameters Setting Handshaking Protocol ...............................13 ACK/ NAK Response Time Setting ............14 Baud Rate.................................................15 Data Bit.....................................................15 Stop Bit.....................................................15 Parity Setting ............................................16 Message Terminator..................................16 Break Code On/ Off Setting .......................20 Keyboard Emulation Parameters Setting............17 Keyboard Type Selection...........................17 Language Selection...................................19 Message Terminator..................................20 Function Key Emulation.............................21 Capital Lock Setting ..................................21 Reading Code Selection ....................................21 Code 39 Parametrs Setting................................24 Interleaved 2 Of 5 Parameters Setting................25 Chinese Post Code Parameters Setting .............26 UPC/ EAN/ JAN Parameters Setting ..................26 Codabar/ Monarch Parameters Setting ..............30 Code 128 Parameters Setting............................31 MATRIX 25 Parameters setting..........................32 MSI/Plessy parameters setting...........................32 i
Page 5
Italian Pharmac Parameters Setting................... 34 ISBN/ ISSN Conversion .................................... 35 Wand Emulation Parameters Setting ................. 36 Emulation Speed Selection ....................... 36 Emulation Data Output Selection............... 36 Appendix A Code 39 Full ASCII Code Table ......................... 38 Appendix B Code 39 Full ASCII Bar Code Table................... 41
1. INTRODUCTION The series scanners can be configured by scanning a series of programming bar code labels. This allows decoding options and interface protocols to be tailored to a specific application. The configuration is stored in non-volatile memory and will not be lost by removing power from the scanner. The scanner must be properly powered before programming. For RS-232C type scanners, an external power adapter must be used to supply DC power to the scanner. If a keyboard emulation type scanner is used with a IBM PC/XT/AT, PS/2 or any fully compatible computers, power will be drawn from the keyboard port. No external power adapter is required. If keyboard emulation type scanner is used with any other non IBM PC compatible computers, an external power adapter may be needed. During the programming mode, the laser scanner will acknowledge a good and valid reading with a short beep. It will give long beeps for either an invalid or bad reading. 2. PROGRAMMING OPTIONS Programmable options are divided into four groups. The first group includes the options that show the general behavior of the laser scanner. The second group of options governs the operation of RS-232C type serial ports. The third group selects the keyboard type that the keyboard emulation type will be emulated. The last group sets the decoding parameters for each bar code symbology.
ii
1
Page 6
3. DEFAULT PARAMETERS
DEFAULT VALUES OF KEYBOARD EMULATION PARAMETERS SETTING
This table gives the default settings of all the programmable parameters. The default settings will be restored whenever the "Reset" programming label is scanned and the laser scanner is in programming mode. DEFAULT VALUES OF OPERATING PARAMETERS Function Scanning Mode Selection Header and trailer Inter-Message delay Inter-Character delay Message/Block mode selection Send command in block mode communication Good read beeper tone selection Code identifier transmitting Code 39 bar code identifier code ITF 2 of 5 bar code identifier code Chinese post code identifier code UPC-E bar code identifier code UPC-A bar code identifier code EAN-13 bar code identifier code EAN-8 bar code identifier code Codabar bar code identifier code Code 128 bar code identifier code Code 93 bar code identifier code MSI bar code identifier code MATRIX 25 bar code identifier code
2
Default Values Trigger mode None Normal Normal Message
Function
Default Values
Keyboard type selection Message terminator
IBM PC/AT USA Enter/ carriage return
DEFAULT VALUES OF RS-232C SERIAL COMMUNICATION PARAMETERS Function
Default Values
Handshaking protocol ACK/NAK response time setting Baud rate
None
Disable
Data bit
2.3KHz/50 mSec (for alpha-50) 2.7KHz/50 msec (for alpha-70) Disable M I H E A F FF N K L P
Stop bit
300 msec 9600 8 1
Parity Message terminator selection
Mark (None) CR/LF
DEFAULT VALUES OF WAND EMULATION PARAMETERS Function
Default Values
¡ °Wand emulation speed ¡ °Wand emulation output
Normal Black = High
Note: For wand emulation, the configuration is only effective for the items with asterisk (¡ ° ).
G
3
Page 7
DEFAULT VALUES OF DECODING PARAMETERS Function
Code
Default Value
Code 39 Enable ITF 2 of 5 Enable Chinese Post Code Disable UPC/EAN/JAN Enable Codabar Enable Reading codes ¡ ° Disable MSI selection Code 128 Enable Code 93 Enable Disable ¡° ITAT Disable ¡ ° EAN-128 Disable ¡ ° MATRIX 25 Disable ¡° Italian Pharmac ISSN/ ISBN Disable Codes Standard Start/stop characters Not transmitting Code 39 Check digit Disabled Concatenation Off Interleaved Length 6-32 digits 2 of 5 Check digit Disable Chinese Post Length 10~16 digits Code Check digit Transmit Format All Addendum Disable UPC-E=UPC-A Disabled UPC/EAN/JAN UPC-A leading digit Transmit UPC-A check digit Transmit UPC-E leading digit Transmit UPC-E check digit Transmit Type Standard Codabar Start/stop characters A,B,C,D Length 6~32 digits Code 128 FNC 2 append Disable Check digit Disable MSI Length Variable Check digit Transmit Italian Pharmac Transmit "A" Not transmitting Character MATRIX 25 Length Fix 10 digits Check digit Disable
4
Note: The configuration of the items with asterisk (¡ ° ) is effective when being appointed in advance. 4. PROGRAM PROCEDURE USING BAR CODE MENUS
NO
NO
YES
YES
5
Page 8
Without any scanning, the unit will enter a standby mode. To reactivate the unit, present an object in front of the IR sensor. (*Only for Alpha-60 series.)
Start of Configuration
RESET
• The reading of the "RESET” label turns all the parameters back to default values. • When you intend to turn your scanner back to default parameter, please scan the "Start of configuration" label first, then scan "RESET" label and finally scan the "End of configuration" label. • The reading of the "ABORT" label discards all the parameters read
ABORT prior to the
"End of configuration". • The scanner remains in the last
RS-232C interface mode scanner is reset.
when the
The label below should be scanned if the scanner is configured the first
PC/AT time. • The reading of the
“ SHOW
Object detect Trigger Note: To avoid hazardous exposure, all laser scanner are equipped with an internal cut-off security system which will turn off the laser beam after 5 seconds.
SCANNING MODE SELECTION (For Alpha-70 series) The scanner becomes inactive as soon as the data is transmitted. It must be triggered to become active again.
Trigger mode In auto scan mode, the scanner is still active after the data is transmitted, but the successive transmission of the same bar code is not allowed when the trigger switch is pressed again. This scanner will light up when press the scanner trigger switch once. And, the scanner will turn off for next pressing.
Auto scan mode
Alternate mode
For testing the response of the scanner.
Repeat mode
For factory testing use only.
VERSION” label will be show
WAND EMULATION firmware version.
Testing mode
DATA REDUNDANT CHECK
SHOW VERSION
SCANNING MODE SELECTION(for laser scanner) For series laser scanners, there are 3 scanning modes to suit your application requirements.
Trigger Mode
Turbo Trigger Mode
The option allow you to set decoder data redundant check.
Enable
The scanner becomes inactive as soon as the data is transmitted. It must be triggered to become active again. The scanner switch is pressed and double reading for the same bar code is permitted. The scanner will turn off when the trigger switch is released.
Disable
End of Configuration
6
7
Page 9
INTER-CHARACTER DELAY This option governs delay time between consecutive characters. The delay time can be altered by scanning the following labels.
Start of Configuration
HEADER AND TRAILER This option allows you to append a header and/or a trailer to every message transmitted via the serial ports or the keyboard port. There is no restriction in selecting header or trailer characters as far as the sum of the lengths of header and trailer is not greater than 10 digits.
Header
Trailer
1. Select either header or trailer you are going to program by scanning the corresponding label 2. Scan the character(s) you want from the enclosed ASCII table to set as header or trailer (be sure to enable full ASCII code 39 option before you start). 3. Read the “ Set” label to set your choice into memory.
Set
INTER-MESSAGE DELAY There series Laser scanners allow you to add a delay between two consecutive messages. This delay will be added before each data transmission. Start of Configuration label and then select the appropriate delay time to activate this feature.
None
None
10 mSec
20 mSec
50 mSec
MESSAGE/BLOCK MODE SELECTION This option allows you to treat scanned data as either an independent message or a block message. In the message mode, the data scanned will be transmitted immediately. In block mode, the data scanned will be appended to the message buffer if the scanner is programmed in block mode. A block of message will only be transmitted after a “Send” command is entered. This mode is only available when the scanner is working with code 39 labels. You are free to choose any character as the “ Send” command.
100mSec
Message
500 mSec
Block
1 Second
8
End of Configuration
9
Page 10
SOUND DURATION Start of Configuration
SEND COMMAND IN BLOCK MODE COMMUNICATION You can use this option to set your own “Send” command used in block mode communication.
long(120ms)
Medium(50ms) Enable
Short(20ms) Disable
Very short(5ms) Store
Set
GOOD READ BEEPER TONE SELECTION You can use this option to set frequency and / or duration of the buzzer after successful reading.
BAR CODE IDENTIFIER CODE SELECTION The series RS-232C and keyboard emulation types scanners can transmit max. 2 digits bar code identifier code for different types of bar codes. Use the labels to choose transmit or not transmit bar code identifier code:
Enable Medium Disable Low
End of Configuration High
Disable
*For Alpha-70 only Medium and disable setting available. 10
11