Page 151
Appendix J
UPC / EAN Specifications UPC symbols are found on almost all grocery products and many other retail items. The UPC code most people are familiar with (UPC-A) is a fixed-length (12 digits) numeric only code, with the first digit controlled by UPC coding assignments and the last digit a checksum. UPC-E and UPC-E1 are variations of the standard UPC-A code. Each digit is constructed of two bars and two spaces. UPC has very precise standards of code size, structure, and numbers to be used. EAN is an international superset of UPC. EAN13 has 13 digits, with the first two digits representing a country code. The final digit is, as with UPC, a check digit. EAN-8 is a shorter version on the EAN-13 code containing seven data digits and ending again with a checksum. The exact UPC/EAN symbol specifications are available from: Uniform Code Council, Inc. 7887 Washington Village Drive, Suite 300 Dayton, OH 45459 937-435-3870 Specifications are also available via the internet at: http://www.uc-council.org Keep the following guidelines in mind when printing UPC bar codes: • If you plan to use a "supermarket-type" in-counter scanner to read the codes, specify a bar code height of at least .9" for an optimal first read rate. • Make it an early practice to observe the numbering conventions of the UPC Council. Do not label unmarked merchandise with a bar code whose numbers may conflict with those already assigned. If products with these numbers are not in your store now, they are likely to be in the future, causing conflicts in your inventory system.
J-1
Page 152
• The leading Number System Character, (the first number of the 11 digits to be entered) should conform to these UPC assignments: 0,6,7 Regular UPC 12 digit codes with numbers assigned by the UPC Council. (Do not use 0 as the leading number for in-store marking). 2 Store-marked random weight items of meat and produce. 3 Reserved for National Drug Code and Health Related Items. 4 Use this leading digit for in-store marking of non-food items. 5 Reserved for coupons. Do not use this today, or you will not be able to process coupons through your system tomorrow.
Supplemental codes The UPC standards include the addition of a 2 or 5-character supplemental code as well as the Extended Coupon Code. To read the supplements, you must first enable them using the RF Terminal Setup Menu. NOTE: Enabling the supplements disallows the reading of UPC codes from right to left to assure that the 2 and 5 digit supplements are not get missed. Coupon codes can be read from right to left or left to right.
ISBN Specifications ISBN (International Standard Book Numbering) bar codes are essentially EAN-13 with a 5 digit supplement, where the first 3 digits are the Bookland country codes of 978 for books and 977 for periodicals. Although the bar code contains 18 characters, the ISBN format uses only 9 of them, along with a newly calculated Mod-11 check digit. For example, a bar code containing the numbers 978055337062153495 would transmit as 0553370626 in the ISBN format. The RF Terminal has the option of transmitting in the ISBN format.
ISBN 0-553-37062
J-2
Page 153
ISBN specifications are available from: American National Standards Institute Customer Service 11 West 42nd St. New York, NY 10036 http://web.ansi.org document ISO 2108:1992
The UPC/EAN checksum character The last character in a UPC-A, UPC-E, UPC-E1, EAN-13 or EAN-8 bar code is the checksum. For reference, these are the methods of calculation:
Checksum calculation for UPC-A, EAN-13 and EAN-8 Use Worth Data's phone number (it's not a real UPC-A code) as sample data: 18314589938 Assign even and odd positions, starting at the right and moving left: 8
3
9
9
8
5
4
1
3
8
1 odd even odd even odd even odd even odd even odd
1. Starting with the leading digit, 8, take the sum of all the characters in the odd positions. 8 + 9 +8 + 4 + 3 + 1 = 33 2. Multiply the result of step 1 by 3. 33 x 3 = 99 3. Now take the sum of all the even-position characters. 3 + 9 + 5 + 1 + 8 = 26 4. Add the result in Step 2 to the result in Step 3. 99 + 26 = 125 5. Subtract the result from the next higher multiple of 10. Next higher multiple of 10 over 125 = 130
130 - 125 = 5 5 is the Modulo-10 check character. The data to be printed becomes: 183145899385. This same formula is used for EAN-13 (using the 1-12 digits) and EAN-8 (using the 1-7 digits). J-3
Page 154
UPC-E Checksum Calculation Use the sample data of 123456 to demonstrate the UPC-E checksum calculation: 1.
The 6 digit UPC-E code is converted to a 10-digit code, using an expansion scheme based on the sixth digit: If the code ends in:
UPC-E Data
Insertion Digits
Insertion Position
10 digit code
0 1 2 3 4 5 6 7 8 9 abcde0 abcde1 abcde2 abcde3 abcde4 abcde5 abcde6 abcde7 abcde8 abcde9
00000 10000 20000 00000 00000 0000 0000 0000 0000 0000
3 3 3 4 5 6 6 6 6 6 ab00000cde ab10000cde ab20000cde abc00000de abcd00000e abcde00005 abcde00006 abcde00007 abcde00008 abcde00009
Because the sample UPC-E code ends in a 6, the insertion digits 0000 are inserted at the sixth digit (insertion position 6): 1234500006 2.
Add the Number System Character of 0 to the sample data: 01234500006
3.
Use the UPC-A check digit calculation described in the previous section to produce a check digit as if it were a UPC-A code. The check digit for the sample data is: 5
4.
The complete 8 digit code consists of the Number System Character, the original 6 digit code and the check digit: 01234565
J-4
Page 155
Appendix K
MSI/Plessey Specifications Plessey is a variable length numeric only bar code. MSI Bar Code is a variable length, numeric-only code with an automatically appended Modulus 10 check digit. MSI is sometimes called Modified Plessey Code. If the user specifies an additional check digit, the MSI code can be 14 digits long, otherwise it has a maximum length of 13 characters. This is how the MSI check digit(s) are calculated: The MSI Mod 10 check digit is calculated as follows: The example bar code data is: 82345 1. Form a number from the odd positions, starting in the units position. 835 2.
Multiply the new number by 2 (835) x 2 = 1670
3.
Add the digits of product 1 + 6 + 7 + 0 = 14
4.
Add the even digits of the original number to the result in 3 2 + 4 + 14 = 20
5.
Subtract the result from the next highest multiple of 10 20 - 20 = 0
6. New Check Digit 0 7.
Data with check digit is: 823450
K-1
Page 156
The MSI Mod 11 check digit is calculated as follows: The example bar code data is: 943457842 1.
Assign a checking factor to each number, starting with the units position of the number (in this example, the 2) up to the highest order position (the 9). Use checking factors of: 2,3,4,5,6,7,2,3,4,5,6,7...
2.
Multiply the checking factor with its assigned number and add the products: 4 + 12 + 32 + 35 + 30 + 28 + 6 + 12 + 36 = 195
3.
Divide the sum by 11 195/11 = 17 remainder 8
4.
Subtract remainder from 11 11 - 8 = 3
5.
New Check Digit 3 (If the remainder is 10, no check digit is added.)
6.
Data with check digit is: 943457823
K-2
Page 157
Appendix L
Piggyback Laser Installation The RF Terminal can use a hand-held Laser scanner (such as the LZ100, LZ200 and Symbol 3200 models) in what we call a "Piggyback" configuration. This configuration has the RF Terminal connected to the laser with a short cable and velcro strips to secure the RF Terminal to the top of the laser. This creates an all-in-one RF Terminal/Laser scanner. Follow these steps to complete the Piggyback installation: 1.
If the normal long coiled laser cable is still plugged into the LZx00 laser, use a pencil or flat head screwdriver to depress the tab on the RJ45 connector of the cable at the base of the laser scanner. Pull out the cable while depressing the tab.
2.
Insert the untagged end of the T24 Piggyback cable into the laser. This cable is considerably shorter than the original laser cable.
3.
Place the velcro strips on the top of the laser and the back of the RF Terminal separately according to the diagram below. Firmly press on the velcro surface to be sure the sticky back makes complete contact with the surface of the laser and RF Terminal.
4.
Plug the tagged end of the T24 Piggyback cable into the RF Terminal SCANNER port.
A carrying case, the T47 is available for this configuration. It is a one piece carrying case designed to help stabilize and protect the RF Terminal and Laser. See Appendix N; Optional Features for greater detail.
L-1
Page 158
Piggyback attachment for laser and RF Terminal
RF Terminal Piggyback configuration
L-2
Page 159
Appendix M
How to scan a bar code The RF Terminal can be used with a variety of scanners – wands, lasers, and CCDs. Which one you choose is dependent upon your application and the quality and density of your bar codes. This section will include information on different scanners as well as how to use each one.
Wand Scanners The RF Terminal can be used with the F57 Switch Wand. Scanning with a wand is like drawing a line with a pencil - hold the wand as you would a pencil, about 30 degrees from perpendicular. Squeeze the wide black rubber band (there should now be red light coming from the end of the wand) and “draw” a line through the bar code, starting about ¼” before the bar code and making sure you end at least ¼” past the end of the bar code. You do not have to press hard – a light touch is fine and scanning quickly is preferred to scanning slowly. The key to wand scanning is to make sure you stay on the bar code the whole way though.
Laser and CCD Scanners If you are using a laser or CCD scanner, technique is not as critical. The scanners are “point-and-shoot”; you can’t miss. Upon triggering the beam, the laser and CCD scans the bar code multiple times (36 scans per second) until it has a good read, at which point it automatically shuts off. These scanners are more expensive, but virtually foolproof. They read from a distance, so they are much more convenient for distance shelf scanning or scanning in tight spots. Different laser scanners have different distance capabilities. Table M-1 shows the comparison of all the laser and CCD scanners available from Worth Data. Scanner
Hi Density Code 39
UPC 100%
40 mil Code 39
Paper 100 mil Code39
Retro-Reflective 100 mil Code 39
LI50 CCD
0.5” – 4”
0.5 - 7”
1” – 12” na
20” – 40”
LZ100 Laser LZ200 Laser & Terminal’s Integrated Laser
0 – 6”
0 – 12”
2” – 41”
7” – 41”
28” – 7.5 ft.
0.5” – 9”
0 – 17”
3” – 44”
9” – 50”
18” – 9.5 ft.
Symbol 3200 Laser
3.5” – 11”
2” - 22”
10” – 13 ft.
24” – 15 ft.
32” – 28.5 ft.
Table M-1. Scanner Comparison Chart 6 mil = high density 40 mil = low density 100 mil = very low density (with paper and retro-reflective label stock)
M-1
Page 160
To scan a bar code using your laser or CCD scanner, (whether it be a handheld or integrated) 1.
put your RF Terminal in One-Way mode with the host computer program not running; or even unplug the serial cable,
2.
point the laser scanner at the bar code at about 6” away.
3.
Pull the trigger (or push the button on an integrated model) and line up the beam on the bar code. If you don’t get a read, vary the distance of the scanner from the bar code by pulling up or moving down. Just as with the wand, the idea is to scan through the center of the bar code.
Laser Options Several options are applicable to all laser and CCD Scanners that are used with the RF Terminal. These options are: 1) Longer timeout on the laser reading, and 2) Double decode required. Longer Laser Reading: A temporary solution to problem bar codes is sometimes to increase the length of the time the scanner attempts to read, from the default 2-second beam to a 4-second beam. To select the 4-second beam: Scan Start Setup Scan Laser Options Scan 3 to select the 4-second beam Scan End Setup To return to the default 2-second beam, scan 0. Double Decode: The default setting for the RF Terminal is one successful decode results in a “good read”. If you are getting incorrect reads, (due to defective bar codes), a temporary solution is to turn on make the RF Terminal perform two straight identical decodes before beeping, outputting data, and completing a “good read” read. To activate the double decode: Scan Start Setup Scan Laser Options Scan 1 to select double decode Scan End Setup To return to the single decode beam, scan 0. There are two Setup Options that are only apply to the Integrated RF Terminal and the LZ200 laser scanner (they both use the same model of scan engine). The two options are:
M-2