The text of a manual · part 27 of 46
FIS-6801 Industrial Scanner User's Manual, pages 261 to 270
Pages 261 to 270 of 454
The original document is the PDF (7.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-6801
Page 261
Parameters
Symbol Contrast Threshold This is the grade to use as a threshold for driving the output. Output will be driven if the Symbol Contrast grade is under the threshold.
Print Growth Threshold This is the grade to use as a threshold for driving the output. Output will be driven if the Print Growth grade is under the threshold.
Axial Non-Uniformity Threshold This is the grade to use as a threshold for driving the output. Output will be driven if the Axial Non-Uniformity grade is under the threshold.
Unused ECC Threshold This is the grade to use as a threshold for driving the output. Output will be driven if the Unused ECC grade is under the threshold.
FIS-6801 Industrial Scanner User’s Manual
5-159
Page 262
I/O Parameters
Diagnostics Note: Output On under Output 3 Parameters must be set to Diagnostic Warning for this output to function. Under Output 3 Parameters, expand the Diagnostics tree. When Diagnostic Warning is enabled, the Output On configuration has no effect. The output will remain active as long as one of the diagnostic warning conditions is met. The output will become inactive once it detects that there are no diagnostic warning conditions.
Service Unit Allows the user to set up the output to toggle to active when the service timer has expired. This condition will only be held for one service timer click. Note: This feature cannot be used if the Scanner is in Continuous Read. When Service Unit is enabled, a message of up to 10 ASCII characters is sent whenever the system detects that the service timer’s limit has been reached. The service timer is reset at power-on, meaning that the service timer’s limit is the amount of time since last reset. Service timer increments can be set in seconds or minutes.
5-160
FIS-6801 Industrial Scanner User’s Manual
Page 263
Parameters
Quality Output
Quality Output Separator The separator character separates quality output data from symbol data.
Decodes per Trigger Status When Enabled, the Scanner enters a state where it processes frames as configured until the end of a read cycle, with or without a successful symbol decode. When the read cycle ends, the Scanner outputs any decoded symbol data along with the decodes per trigger count.
FIS-6801 Industrial Scanner User’s Manual
5-161
Page 264
Symbol Quality
Symbol Quality Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Symbol Quality tab to display the Symbol Quality tree control.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Symbol Quality settings can also be sent to the Scanner from ESP’s Terminal using wenglor’s K command format.
5-162
FIS-6801 Industrial Scanner User’s Manual
Page 265
Parameters
Global
Total Read Time When enabled, outputs the amount of time that was required by the Scanner to decode the symbol.
Symbol Quality Separator This field specifies the separator used to separate the quality output data.
Output Mode Determines how symbol quality evaluations will be output.
FIS-6801 Industrial Scanner User’s Manual
5-163
Page 266
Symbol Quality
Data Matrix
ISO/IEC 16022 Parameters
Symbol Contrast Outputs the candidate symbol’s Symbol Contrast value.
Print Growth Outputs the candidate symbol’s Print Growth value.
Axial Non-Uniformity Outputs the candidate symbol’s Axial Non-Uniformity value.
Unused ECC Outputs the candidate symbol’s Unused ECC value.
5-164
FIS-6801 Industrial Scanner User’s Manual
Page 267
Parameters
Grading
Percent Cell Damage The percent of symbol cells that are damaged.
Capture Time The amount of time the Scanner required to capture the area in which the symbol was located.
Locate Time The amount of time the Scanner required to locate the symbol.
Decode Time The amount of time the Scanner required to decode the symbol.
Pixels Per Element The average number of pixels in a symbol element.
ECC Level The level of error correction used when decoding the symbol.
Matrix Size The size of the symbol’s matrix area (the area composed of the symbol’s elements).
Quiet Zone The size of the quiet zone around the symbol.
Symbol Angle The angle at which the symbol is printed or marked.
FIS-6801 Industrial Scanner User’s Manual
5-165
Page 268
Symbol Quality
Report Tab The Report tab allows the user to initiate Data Matrix Grading and to generate and save grading reports. To save the report as a PDF file, an HTML file, a CSV file, or an RTF file, click the Save Report button. Reports appear in the viewing area underneath the Data Matrix Grading and Save Report buttons.
The Symbol Quality interface is divided into three sections: Report, Locate, and Preferences.
The Scanner’s field of view is shown here. When grading is completed, the initial
5-166
FIS-6801 Industrial Scanner User’s Manual
Page 269
Parameters
Locate Tab The Locate tab allows the user to determine the position of the symbol within the Scanner’s field of view, and to optimize the Scanner’s camera settings for symbol quality evaluation.
Click the Locate button to display the symbol in the Scanner’s field of view.
FIS-6801 Industrial Scanner User’s Manual
Click the Calibrate button to optimize camera settings.
5-167
Page 270
Symbol Quality
5-168
FIS-6801 Industrial Scanner User’s Manual