The text of a manual · part 2 of 46
FIS-6801 Industrial Scanner User's Manual, pages 11 to 20
Pages 11 to 20 of 454
The original document is the PDF (7.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wenglor FIS-6801
Page 11
Quick Start
Step 2, Connect the System Standard FIS-6801 Important: When connecting Ultra-Lock cordsets to the FIS-6801 and ZAA12NN01, align the pins first and then push the connector into place. Do not twist the connectors, as this will bend the pins. Important: Do not attempt to power more than four Scanners with a single power supply in a daisy chain configuration. Add a ZAA12NN01 and one power supply for every four additional Scanners in the daisy chain.
RS-232 • Connect the Serial Communication Cable from “A” on the FIS-6801 to “2” on the ZAA12NN01. • Connect the host cable from “1” on the ZAA12NN01 to the host computer. • Connect the photo sensor to “T” on the ZAA12NN01. • Connect the power supply to “3” on the ZAA12NN01. • Plug in the power supply.
Ethernet Note: The FIS-6801 does not require an Ethernet crossover cordset, because the Scanner itself performs automatic internal crossover (transmit-to-receive switching). wenglor offers a standard straight-through (un-crossed) Ethernet cordset (61-000160-01). • Connect the Ethernet Cable from “B” on the FIS-6801 to the network. • Connect the photo sensor to “T” on the ZAA12NN01. • Connect the power supply to “A” on the FIS-6801.
FIS-6801 Industrial Scanner User’s Manual
1-3
Page 12
Connect the System • Plug in the power supply. 1
1
7 3
5 2
2
6
8
Serial Standalone (with ZAA12NN01)
1-4
3
6
8
Ethernet Standalone (with ZAA12NN01)
FIS-6801 Industrial Scanner User’s Manual
Page 13
Quick Start
Step 3, Position the Scanner • Position the Scanner at a focal distance of one inch or more from a test symbol. • Tip the Scanner relative to the symbol if necessary to avoid the glare of direct (specular) reflection. • Symbols can be rotated (tilted) at any angle; however, for best results symbols should be aligned with the field of view. In the case of linear symbols, aligning the bars in the direction of their movement (ladder orientation) will minimize the chances of blurring and will result in more consistent decodes.
Standard FIS-6801 Scanner and Symbol Orientation
Important: Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°.
FIS-6801 Industrial Scanner User’s Manual
1-5
Page 14
Install ESP
Step 4, Install ESP ESP Software can be found on the wenglor Tools Drive or Tools CD that is packaged with the FIS-6801 and FIS-6801 C-Mount. 1. Follow the prompts to install ESP from the Tools Drive or Tools CD. 2. Click on the ESP icon to run the program.
Note: ESP can also be installed from the Download Center at www.wenglor.com.
Minimum System Requirements • 233 MHz Pentium processor • Windows 7 (32-bit or 64-bit), Vista (32-bit or 64-bit), XP, or 2000 operating system • Internet Explorer 6.0 or higher • 128 MB RAM or greater • 80 MB hard drive space • 800 x 600 minimum 256 color display (1024 x 768 32-bit color recommended)
1-6
FIS-6801 Industrial Scanner User’s Manual
Page 15
Quick Start
Step 5, Select Model Standard FIS-6801 When you start ESP, the model menu will appear:
1. Click the button showing the FIS-6801. 2. Click OK. Note: You can also simply double-click the button showing your Scanner to make your selection. 3. Click Yes when the following dialog appears:
Note: If you need to select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar. FIS-6801 Industrial Scanner User’s Manual
1-7
Page 16
Connect
Step 6, Connect Connection Wizard To connect using the Connection Wizard: • Click Connect on the menu toolbar, and then select Connection Wizard. • Select RS-232 or Ethernet to activate the appropriate display. • Configure settings as required by the application, and click Connect.
RS-232 Connection Wizard
Ethernet Connection Wizard
• When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible:
Important: The Scanner is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the Scanner’s field of view while attempting to connect.
1-8
FIS-6801 Industrial Scanner User’s Manual
Page 17
Quick Start
Step 6, Connect (cont.) Ethernet TCP/IP Once the FIS-6801 is connected, incoming symbol data can be displayed in the Terminal, as shown below.
FIS-6801 Industrial Scanner User’s Manual
1-9
Page 18
Locate Symbol
Step 7, Locate Symbol Locate by ESP • In ESP’s EZ Mode, click the Locate button to enable the red X pattern.
The symbol in the field of view will appear in the video view beneath the Locate and Calibrate buttons, and you will see the red target pattern projected from the front of the Scanner. Note: The FIS-6801 C-Mount does not display a target pattern. • Center the target pattern on the symbol.
Important: The entire symbol should fall within the field of view (FOV) of the Scanner. The field of view is what appears in ESP’s Locate/Calibrate window in EZ Mode. • Click the Stop button to end the Locate function.
1-10
FIS-6801 Industrial Scanner User’s Manual
Page 19
Quick Start
Locate by EZ Button If you are not connected to a host computer, the EZ Button allows you to locate a symbol in the Scanner’s field of view.
EZ Button
• Hold down the EZ Button for about one second and release when you hear one short beep. The amber 20% LED will illuminate, and you will see the red target pattern projected from the front of the Scanner. • Center the target pattern on the symbol. Note: To end all EZ Button functions, press the EZ Button once and quickly release.
FIS-6801 Industrial Scanner User’s Manual
1-11
Page 20
Calibrate
Step 8, Calibrate Scanner settings can be adjusted automatically for optimum performance by either the EZ Button or by ESP. During the calibration routine, the Scanner will flash its amber Read Rate percent LEDs and illumination LEDs while searching camera settings and determining the best configuration for decoding symbol data. Upon successful completion of this routine, a green LED pattern will flash brightly and illuminate the symbol. If unsuccessful, the ScannerScanner will emit 5 short beeps and stop searching.
Calibrate by ESP 1. Click the Calibrate button.
2. The Scanner will search camera settings to determine the best configuration for decoding symbol data. A successful calibration will display a green frame around the symbol, and the following message will appear: “Uploading all reader parameters.” After a moment the symbol data will be presented in the field below the image display window.
Calibrate by EZ Button 1. Hold down the EZ Button for about two seconds and release when you hear two short beeps. The 20% and 40% LEDs will illuminate. 2. The Scanner will search camera settings to determine the best configuration for decoding symbol data. Note: To end all EZ Button functions, press the EZ Button once and quickly release.
Calibrate by Serial Command Send <@CAL> from a terminal program to begin auto-calibration. 1-12
FIS-6801 Industrial Scanner User’s Manual