Page 46

Power Power Options

Lithium-Ion @7.4V, 1800mAH Main Battery Pack (Battery pack can be recharged 500 cycles or more) External AC/DC adapter @12VDC/2A with regulator

Power Consumption

Lithium-Ion battery: At 8V Standby mode: 100mA Suspend mode: 5mA

Battery Charge

3 hours with external AC/DC adapter 3 hours with docking station

Backup Battery

1 rechargeable1.2V, 600mAH Ni-MH battery cell for data backup

Power Management

Power consumption indicated on status bar

Barcode/Symbology Symbology

Codabar Code 11 Code 32 Code 39 Code 39 Full ASCII Code 93 Code 128 Delta Code EAN-8, 13

EAN128 Interleaved 2 of 5 Label Code MSI/Plessy Standard 2 of 5 Toshiba Telpen Toshiba UPC-A, E

OS and Software Programming Tools OS

Microsoft Windows CE.Net Version 4.2

Development Language

Microsoft Embedded Visual Tool for VB and VC programming, Visual Studio .Net 2003

46

Wasp WPA206

Page 47

Mechanical and Environmental Dimensions

Length: 7.28” (18.5cm) Width:

3.49” (8.76cm)

Depth:

1.70” (4.33cm)

Weight

15.59 oz. (442g) with battery pack

IP Rating

IP 54

Temperature

Operation: -5°C to 50°C Storage: -20°C to 60°C

Humidity

5% to 95% RH non-condensing

Shock

Multiple 4.0’ (1.2m) drops to concrete

Docking Station Interface

1 EIA RS232C IDC type connector via PC/computer, 1 USB port

Power Input

16 pin connector for charging and communication pads to main unit Quick charging typically takes 3 hours AC/DC adapter @ 12 VDC/2A with regulator

Pin Assignment of Charge and Communication Port P in

A ssignm ent

1

DCD

D escription

2

RXD

3

TX D

S end D ata

4

DTR

D ata T ransm it R eady

R ec eive D ata

5

SG

S ig nal G round

6

D SR

D ata S et R eady

7

RTS

R equest to S end

8

CTS

C lear to S end

9

RI

R ing Indicator

10

U S B 5V

U S B 5V

11

12V

12V Input

12

NC

13

NC

14

G DN

G round

15

UDC

U S B D ifferential D ata S ig nal H ig h S ide

16

/U D C

U S B D ifferential D ata S ignal Low S ide

Product Reference Guide

47

Page 48

Appendix B Update and Upgrade OS Update OS via Compact Flash (ATA card) In order to upgrade or re-install the WPA206 OS via Compact Flash, you will require the NK.bin file (available from Wasp Technical Support):

Note: File name must be “NK.bin” – do not rename it. CAUTION: Users files will be erased! 1. Copy file “NK.bin” from the PC to the root directory of the Compact Flash card.

Insert CompactFlash chip into PC Card Adapter

2. Insert the Compact Flash Card into the WPA206. 3. Plug the power adapter into the WPA206. 4. Run \Windows\BootMode.exe from WPA206 by tapping My Computer -> Windows -> double tapping “BootMode” . 5. Press OK. 6. The WPA206 will display the following screen: WPA206 BootLoader Ver 1.11, - - - - - - - - - - - - - - - - - - WPA206 Boot Loader Option (1) Ethernet Image Update (2) OS Image Update (3) Boot Loader Update (4) Serial Port Image Update (5) Jump to WinCE (6) Flash Erase, - - - - - - - - - - - - - - - - - - Choise:

48

Wasp WPA206

Page 49

7. Press the ‘2’ key to select “OS Image Update”. FlashRom’s content will be erased and the new OS will be written to FlashRom. Then you will see the system will automaticlly run the following steps.: (1). Image goint to Flash (2). Erasing Flash (3). New programming Flash After the OS is successfully updated, the WPA206 will automatically cold-start with the new OS.

Product Reference Guide

49

Page 50

Appendix C Troubleshooting Guide Problem Terminal does not power on

Solution Battery needs recharging or replacement Insure that the battery is installed correctly

Terminal shuts itself down

Adjust “Power Properties” Battery needs recharging Adjust “Power Properties” - especially if peripherals are used

Battery life is short

Adjust backlight of LCD or Keypad Replace battery pack if old (battery can be recharged approximately 500 cycles)

“Low Backup Battery” message Screen is blank

Charge terminal for 16 hours Make sure the terminal is powered on Adjust screen brightness Calibrate touch screen

Terminal either does not respond, or responds inaccurately to touch screen input.

Perform a warm boot - WARNING - Unsaved data will be lost Perform a cold boot - WARNING - Terminal will be reset to factory default settings and data will be lost Make sure scanning application is loaded and operational

Bar code does not read

Run “Scanner Setting” program to modify barcode read setting Bar code might be distorted and should be replaced Battery needs recharging or replacement If terminal is processing data, attach charging cable to insure the battery isn’t depleted If terminal is connected to AC power, disconnect

Terninal will not shut off

Perform a warm boot - WARNING - Unsaved data will be lost Perform a cold boot - WARNING - Terminal will be reset to factory default settings and data will be lost

50

Wasp WPA206

Page 51

FCC Statement This is a FCC Part 15 Class B product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.

Canadian Compliance Statement This Class B Digital apparatus meets all requirements of the Canadian Interferance-Causing Equipment Regulations. Cet appareil numerique de la classe B respecte les exigences du Reglement sur le material broilleur du Canada. The device is certified to the requirements of RSS-139-1 for 2.4 GHz spread spectrum devices.

European Conformity Statement Declaration of Conformity with Regard to the R&TTE 1999/5/EC and EMC 89/ 336/EEC directives.

Laser Information The Wasp WPA2060 is certified in the U.S. to conform to the requirements of DHHS/CDRH 21CFR Subchapter J and to the requirements of IEC 825-1. Class II and Class 2 products are not considered to be hazardous. The WPA206 contains internally a Visible Laser Diode (VLD) whose emissions do not exceed the maximum limits as set forth in the above regulations. The scanner is designed so that there is no human access to harmful laser light during normal operation, user maintenance or during prescribed service operations. CAUTION - Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light. Use of optical instruments with the scanner will increase eye hazard. Optical instruments include binolulars, microscopes, and magnifying glasses. This does not include eye glasses worn by the user. The laser safety warning label required by the DHHS/IEC for the WPA206’s optional laser scanner module is located on the memory compartment cover, on the back of the unit.

Product Reference Guide

51