Page 41

Delete Probe ID

To delete a probe ID, choose Delete Probe ID from the TouchProbe menu. The Delete Probe ID dialog box appears. Select the probe ID you wish to delete and press Alt D or press the <Tab> key until the Delete button is selected and then press <Enter>. The selected probe ID is deleted. To close the Delete Probe ID dialog box, press Alt C or press the <Tab> key until the Close button is selected and then press <Enter>.

Chapter 3 TouchProbe Learning Guide

33

Page 42

TouchProbe Menu - Configure Probe The TouchProbe menu contains the Configure Probe and Review Probe Configuration commands. When the Configure Probe command is selected, the Configure Probe screen is displayed. The Configure Probe screen shows the configure settings for the TouchProbe. The configure settings are defaulted to Read for each type of Touch Memory button. The 1990 and 1991 buttons are read-only buttons, and Read is the only option available for either of these buttons. The 1992, 1993, and 1994 buttons are read/write buttons; you may configure the TouchProbe to either read or write to any of these three buttons. To access the Configure Probe screen, select the Configure Probe command from the TouchProbe menu by either highlighting the command and pressing <Enter>, or by pressing the C key on the computer keyboard when the TouchProbe menu is open. The Configure Probe screen appears.

Figure 3-7 Configure Probe Screen 34

Chapter 3 TouchProbe Learning Guide

Page 43

The Configure Probe screen allows you to select various options for configuring the TouchProbe. Use the <Tab> key and up and down arrow keys to navigate through the Configure Probe screen. You may select an option by highlighting the option and pressing the <Enter> key. The top left corner of the Configure Probe screen contains a list of all probe IDs that have been added (see Figure 3-8). Use the up and down arrow keys to cycle through the probe IDs. When a probe ID is highlighted, it becomes the active ID and this ID number is also displayed at the lower right of the screen under Probe ID:. The configuration setting for the active probe ID is displayed in the Configure Probe screen. Probe ID List

Active Probe ID Figure 3-8 Configure Probe Screen - Probe ID The Configure Probe screen uses a default of Read Serial #, Date, Time for each button type. If a TouchProbe is configured with this Chapter 3 TouchProbe Learning Guide

35

Page 44

setting, the TouchProbe is able to read the serial numbers of DS1990, DS1991, DS1992, DS1993, and DS1994 Touch Memory buttons. The date and time that a button is read is also recorded in the TouchProbe’s memory with the serial number of the button. Configure Probe Screen - Read and Write Options

There are two sets of options available for configuring a TouchProbe; there is a set of options for reading a button and a set of options for writing to a button. When configuring a TouchProbe to communicate with a read/write button, you must select either Read or Write for each read/write button type. A TouchProbe cannot be configured to both read and write to the same type of a read/write button.

Write Options Read Options Figure 3-9 Configure Probe Screen - Read/Write Options 36

Chapter 3 TouchProbe Learning Guide

Page 45

At the Configure Probe screen, use the <Tab> key to cycle through the Probe ID list, the five different button types, the Configure button, and the Done button. To change the options for a button, press the <Tab> key until the button type is highlighted, then use the up and down arrow keys to navigate through the various option boxes. To select an option, highlight the box next to the option and press the <Enter> key or the <Space bar>. A checkmark appears in the box next to the selected option.

Configure Probe Screen - Read Options

The Read options for a button are: Read from Button: Serial #, Date, Time Read from Button: Serial #, Date, Time, Data The Read option of Serial #, Date, Time, Data has two sub-options: Clear Data from Button and Do Not Clear Data. 1990 and 1991 buttons are read-only buttons. These buttons contain a unique serial number and do not have memory space for additional data; therefore, the read option of Serial #, Date, Time is the only option available for 1990 and 1991 buttons. 1992, 1993, and 1994 buttons are read/write buttons, and besides a unique serial number, they also contain additional memory space for storing data. The Read option of Serial #, Date, Time, Data is an additional Read option for read/write buttons. When this option is configured into a TouchProbe, the TouchProbe records the serial number of the button, the time and date the button is touched, and any data contained in the button. If the Read option of Serial #, Date, Time, Data is selected, either the Do Not Clear Data option or the Clear Data from Button option must also be selected. If the Do Not Clear Data option is selected, the TouchProbe reads the data and the data remains in the button. If the Clear Data from Button option is selected, the TouchProbe clears the data from the button after verifying that the data was read correctly.

Chapter 3 TouchProbe Learning Guide

37

Page 46

Configure Probe Screen - Write Options

The two main Write options for writing to a button are: Write to Button: Probe ID, Date, Time Write to Button: Probe ID, Date, Time, Data The Write option of Probe ID, Date, Time writes the probe ID and the date and time of the write to the button. The Write option of Probe ID, Date, Time, Data writes the probe ID, the date and time, and the data contained in the TouchProbe to a read/write button. This enables the TouchProbe to read serial numbers of buttons, and then write and store the serial numbers in read/write buttons. When one of the Write options is selected, you must also choose either the Append to Data in Button option or the Overwrite Data in Button option. If Append to Data in Button is selected, the TouchProbe’s data is added to the button’s data when the TouchProbe writes to a button. If Overwrite Data in Button is selected, the data contained in the button is replaced by the data in the TouchProbe when the TouchProbe writes to the button. The Write option of Probe ID, Date, Time, Data has two sub-options: Write all Data and Write Data Collected Since Last Write. One of these sub-options must be selected when using the Write option of Probe ID, Date, Time, Data. If you choose the option Write all Data, the TouchProbe writes all of its collected data to the button each time you write to a button. If Write Data Collected Since Last Write is selected, the first time the TouchProbe writes to a button, all of the TouchProbe’s collected data is written to the button. The next time the TouchProbe writes to a button, it only transfers the data collected since the last write to a button.

38

Chapter 3 TouchProbe Learning Guide

Page 47

Configure Probe Screen - Configure

A TouchProbe must be configured before it can store and transfer Touch Memory button data. To configure a TouchProbe, press the <Tab> key until the Configure button is selected and then press the <Enter> key, or type Alt C. Insert the TouchProbe into the downloader. The software begins to configure the TouchProbe. After the TouchProbe has been configured, the screen displays the status of the configured TouchProbe. Remove the TouchProbe from the downloader.

Chapter 3 TouchProbe Learning Guide

39

Page 48

TouchProbe Menu - Review Probe Configuration When the Review Probe Configuration command is selected, the Review Probe Configuration screen appears. When a TouchProbe is configured, a record is kept on the computer of the TouchProbe’s configuration. The Review Probe Configuration screen shows the configuration settings recorded on the computer for the TouchProbe. The Query Probe button asks the TouchProbe how it is configured and then displays the ID number and configuration setting. To query a TouchProbe, place the TouchProbe into the downloader. Press the <Tab> key until the Query Probe button is highlighted, then press <Enter>. The probe ID and the configuration setting for the TouchProbe are displayed.

40

Chapter 3 TouchProbe Learning Guide

Page 49

TouchProbe Menu - Load Text into Probe The Load Text into Probe command allows you to load text into the TouchProbe. The TouchProbe must be configured before you can load text into the TouchProbe. You may enter up to 250 characters of text into a TouchProbe. This text can then be written to read/write buttons. Loading text into a TouchProbe enables you to send textual information from the computer to the TouchProbe, then from the TouchProbe to a read/write button. The text may then be read as data from that button. When you transfer the data from the TouchProbe, all data is cleared from the TouchProbe, including the text.

Main Header Load Text into Probe Data Lines

H 20000129090419 00 12345 H 20000129072238 03 T 03 (Text entered into probe) T 000 Main Tailer

Figure 3-10 Load Text Into Probe Data File Text loaded into the TouchProbe is displayed in the data file as three lines: a Load Text into Probe Header, the text, and a Load Text into Probe Tailer. The Load Text into Probe Header begins with a capital H followed by the date and time the text was loaded into the TouchProbe, followed by a 03. The 03 is the origin code for loading text into the TouchProbe. The next data line is the text entered into the TouchProbe followed by the Load Text into Probe Tailer. The Load Text into Probe Tailer begins with a capital T followed by the 03 origin code. See pages 43–46 for additional information on the TouchProbe data file. Chapter 3 TouchProbe Learning Guide

41

Page 50

TouchProbe Menu - Transfer Data from Probe The Transfer Data from Probe command allows you to transfer the data from the TouchProbe. To transfer data from a TouchProbe, select Transfer Data from Probe from the TouchProbe menu by pressing the down arrow key until the Transfer Data from Probe command is highlighted and then press the <Enter> key, or press the T key from the computer keyboard. The Transfer Data window appears.

Figure 3-11 Transfer Data Window The probe IDs that have been added are displayed in the Probe ID list on the left side of the Transfer Data window. The selected or active probe ID is shown after Probe ID: at the center of the Transfer Data window. Use the up and down arrow keys to select the probe ID you want to transfer. After selecting the probe ID, press the <Tab> key to highlight the Transfer button and then press the <Enter> key. The software begins looking for the TouchProbe. When the software locates the TouchProbe, it transfers the TouchProbe’s data. At the completion of the transfer process, the DATA.TMD file opens allowing you to view the data. Press the <Esc> key to close the DATA.TMD file.

42

Chapter 3 TouchProbe Learning Guide