Chapter 2 TouchProbe - Getting Started This chapter contains: •
Instructions on copying the TouchProbe Communications software onto the hard disk of your computer.
•
A quick-start exercise that introduces configuring the TouchProbe, reading Touch Memory buttons, and transferring the data.
Chapter 2 TouchProbe - Getting Started
13
Page 22
Copy the TouchProbe Communications Software onto the Computer’s Hard Disk To use your TouchProbe Communications program, you need to first copy the software onto your hard disk. Attempting to run the software from a floppy disk results in program errors since its storage space is limited. A general rule is that the software requires free hard disk space equal to the size of the software. The software displays a warning message if hard disk space is low. In the following example, we create a directory for the software called “TOUCH.” You may use another name for the directory by simply substituting your preferred name for “TOUCH” in the following steps. <Enter> symbolizes pressing the computer’s Enter key. <Space> symbolizes pressing the computer’s space bar. 1.
Make a backup of the TouchProbe Communications software disk if you have not already done so. Put the original disk in a safe storage place, and use your backup disk in the following steps.
2.
Insert the backup copy of the TouchProbe Communications software disk into your ‘A’ disk drive.
3.
At the DOS prompt, enter the following: md\TOUCH <Enter>. The “md” means “make directory.” Your screen should look like this: C:\>md\TOUCH
4.
Log on to the new directory by entering the following at the DOS prompt: cd\TOUCH <Enter>. The “cd” means “change directory.” Your screen should look like this: C:\>cd\TOUCH C:\TOUCH>
14
Chapter 2 TouchProbe - Getting Started
Page 23
5.
Copy the files from the disk by entering the following at the DOS prompt: copy <space> a:*.* <Enter>. Your screen should look like this: C:\TOUCH>copy a:*.* This copies all the files from the TouchProbe Communications software disk in drive ‘A’ to the TOUCH directory on the hard disk.
6.
There must be a file called config.sys in the root directory of your hard disk. The root directory is the directory that comes up when you first turn on your computer. The config.sys file must contain a files statement and a buffers statement. For example: Files = 20 Buffers = 8 These are minimum settings for files and buffers. To see if there is a proper config.sys file in your hard disk, log on to the root directory by entering the following at the DOS prompt: cd\ <Enter>; then at the next DOS prompt enter: type config.sys <Enter>. Your screen should look like this: C:\>cd\ C:\>type config.sys The contents of the config.sys file are displayed on the screen. If it does not contain the files and buffers statements, you may add them using a text editor.
The installation of TouchProbe Communications onto your hard disk is now complete. The next section acquaints you with the TouchProbe Communications software with a quick-start exercise. If you have not connected your downloader to the computer’s serial port, do so now. See pages 10–11 for instructions on connecting the TouchProbe Downloader Station to your computer.
Chapter 2 TouchProbe - Getting Started
15
Page 24
Quick-Start Exercise Before proceeding further, we will acquaint you with the TouchProbe Communications software via a quick-start exercise. 1.
To use the TouchProbe Communications software, type cd\touch <Enter> at the DOS prompt. Then type touch <Enter> at the next DOS prompt. Your screen should look like this: C:\>cd\touch C:\TOUCH>touch
2.
The TouchProbe Communications menus appear.
3.
The File menu is highlighted; press the <Enter> key to view the File menu. The File menu allows you to view the data file , change the name and location of the data file, and exit the program.
Figure 2-1 File Menu
16
Chapter 2 TouchProbe - Getting Started
Page 25
4.
Press the right arrow key twice to select the TouchProbe menu. The TouchProbe menu allows you to add and delete IDs, configure the TouchProbe, review the configuration setting, load text into the TouchProbe, and transfer data from the TouchProbe.
Figure 2-2 TouchProbe Menu 5.
Use the up and down arrow keys to choose Add Probe ID from the TouchProbe menu. When the Add Probe ID command is highlighted, press the <Enter> key.
Chapter 2 TouchProbe - Getting Started
17
Page 26
6.
The Add Probe ID dialog box appears.
Figure 2-3 Add Probe ID Dialog Box Each TouchProbe must be given a probe ID. The probe ID may consist of up to ten alphanumeric characters. You may use any alphanumeric characters, and the probe ID may be from one to ten characters in length. Note: Lowercase letters are automatically converted to uppercase.
18
Chapter 2 TouchProbe - Getting Started
Page 27
7.
Enter a probe ID of 12345 at the blinking cursor. (You may use any ID number, but we will use “12345” in this example.)
Figure 2-4 Add Probe ID Dialog Box Press the <Tab> key to highlight the Add button. Press the <Enter> key. The probe ID is added to the Probe IDs box on the left and the Add Probe ID dialog box is ready for another probe ID entry. Press the <Tab> key twice or until the Done button is highlighted. Press the <Enter> key. 8.
Press the <Enter> key to open the TouchProbe menu. Choose Configure Probe from the TouchProbe menu by pressing the down arrow key until it is highlighted and then pressing <Enter>, or by pressing the C key on the computer keyboard.
Chapter 2 TouchProbe - Getting Started
19
Page 28
Probe ID List
Active Probe ID Figure 2-5 Configure Probe Screen The Configure Probe screen appears. The probe ID entered in Step 7 is in the Probe IDs list and is shown as the active Probe ID. The software is shipped with the configure options set to Read for each button type. We will use these default settings for now. See the Configure Probe section that begins on page 33 for detailed information on the screen and the available options. 9.
Insert your TouchProbe into the downloader.
10. Press the <Tab> key until the Configure button is selected and then press the <Enter> key, or type Alt C.
20
Chapter 2 TouchProbe - Getting Started
Page 29
11. The software begins to configure the TouchProbe. 12. After the configuration process is completed, a message appears on the screen to inform you if the TouchProbe has been properly configured. If the TouchProbe was not configured, press the <Enter> key to remove the message from the computer screen. Verify that all of the cable connections to the TouchProbe Downloader Station and the computer are secure, and that the TouchProbe is properly inserted into the downloader. Repeat Step 10. If the TouchProbe was successfully configured, press the <Enter> key to remove the message from the computer screen and continue to Step 13. 13. Remove the TouchProbe from the downloader. 14. Read a few Touch Memory buttons. To read a button, place the TouchProbe contact over a Touch Memory button - the round rim of the button helps guide the TouchProbe for easy alignment. The TouchProbe emits an audible beep and flashes its red LED each time you successfully read a button. 15. Reinsert the TouchProbe into the downloader. 16. Select Transfer Data from Probe from the TouchProbe menu by pressing the down arrow key until the Transfer Data from Probe command is highlighted and then press the <Enter> key, or press the T key from the computer keyboard.
Chapter 2 TouchProbe - Getting Started
21
Page 30
17. The Transfer Data window appears. See Figure 2-6. The probe ID is displayed in the Probe IDs list on the left side of the Transfer Data window and also after Probe ID: at the center of the Transfer Data screen. Press the <Tab> key to highlight the Transfer button and then press the <Enter> key.
Figure 2-6 Transfer Data Window 18. The software begins looking for the TouchProbe. 19. When the software locates the TouchProbe, it transfers the TouchProbe’s data. 20. When the transfer process is completed, the DATA.TMD file opens, allowing you to view the data. 21. Press the <Esc> (Escape) key to close the DATA.TMD file. The Transfer Data window shows the time, date, and status of the transfer. 22. To close the Transfer Data window, press the <Tab> key to select the Done button and then press the <Enter> key, or press the <Esc> key. 23. To exit the TouchProbe Communications software, choose Exit from the File menu. If you have followed the previous steps, you have successfully configured the TouchProbe, read Touch Memory buttons, and transferred the data to
22
Chapter 2 TouchProbe - Getting Started