Spec sheet · Valitec
Valitec AD128 Spec Sheet
Spec sheet2 pagesPDF 370 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A two-page Valitec spec sheet (PSS116A, Rev. 3/98) for the Model AD128 stand-alone data acquisition system. It describes the pocket-sized logging unit and its Configuration & Analysis Software, lists what a system includes, and gives input, data storage, power and communication specifications.
- Device
- Pocket-sized stand-alone data logger with Configuration & Analysis Software and accessories p. 1
- Inputs
- 8 analog and 16 digital inputs, all protected to +/- 20 volts p. 1
- Analog range
- 0 to 5 V (AD128-10: 0 to 10V); resolution 20mV (AD128-10: 40mV) p. 2
- Temperature probes
- Thermistor probes: TP-301 -10 to 150 °C, TP-101 -30 to 120 °C p. 2
- Sampling
- As fast as 500 per second or as slow as one reading every 99 minutes, all inputs at once p. 1
- Data storage
- 130,000 samples; data memory battery life 10 years p. 1, 2
- Power
- 7 to 12 volts from a 9V battery or adapter; 110V-9V 200mA AC adapter p. 2
- Battery life
- Up to 3 months on a 9V alkaline, up to 6 months on lithium p. 2
- PC interface
- RS-232, 9600 bps, 9-pin female, 8 data bits, no parity, 1 stop bit p. 2
- Sensor connector
- Standard DB 25-pin p. 1, 2
- Software
- Configuration & Analysis Software V4.0 for Windows 95, NT and 3.1 p. 1
- System includes
- Logging unit, C&A Software V4.0, 9-pin PC cable, 25-pin sensor interface cable, 9V battery, AC wall adapter p. 1
- Clock
- Built-in real-time clock time-stamps each sample record p. 1
- Optional accessories
- DB25 screw terminal board, 6-ft. DB25 to DB25 cable, NEMA 12 stainless steel enclosure, thermistor sensors p. 1
What this sheet walks you through
- Setting up a recording with form-based configuration, no programming p. 1, 2
- Triggering recording on a condition of the input signal levels p. 1
- Retrieving data into the built-in spreadsheet and graphing it p. 1
Good to know
- Digital inputs are recommended up to 10V, with 100k pull-ups on inputs 1 thru 8. p. 2
- Battery-backed data memory and a software interlock keep data from being lost or erased by accident. p. 1
Questions this sheet answers
How long does the AD128 run on a 9 volt battery?
Up to 3 months on a 9V alkaline battery while recording from all inputs, or up to 6 months on lithium. p. 2
What voltage inputs does the AD128 accept?
0 to 5 V on the AD128 and 0 to 10V on the AD128-10, plus thermistor temperature probes. p. 2
How many samples can the AD128 store?
130,000 samples, kept by a data memory battery rated for 10 years. p. 1, 2
What software does the AD128 use?
Configuration & Analysis Software V4.0, which runs on Windows 95, NT and 3.1. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Valitec Value In Technology
Model AD128 Stand-Alone Data Acquisition System Features
- Lightweight, pocket-sized
- Stand-alone
- Fast, easy setup
- Event-based recording options
- 10-year battery backup
- Runs on Windows 95, NT and 3.1
Configuration & Analysis Software
AD128 Logging Unit
Description The AD128 is a complete stand-alone data acquisition system, including a pocket-sized logging unit, Configuration & Analysis Software and all accessories. This system provides a method for recording directly from industry-standard sensors, instruments and other circuits with output voltages in the range of 0 to 5 volts or 0 to 10 volts, and thermistor temperature probes. The AD128 logging unit will operate from a 9 volt battery for up to 3 months while recording from all 8 analog and 16 digital inputs. Recording can be as slow as one reading every 99 minutes or as fast as 500 per second, sampling all inputs simultaneously. Optionally, recording may be triggered by a specified condition on the input signal levels, eliminating unwanted information. Sample records are time-stamped with the time and date of the built-in real-time clock. The 10-year battery-backed data memory and software interlock ensure that data won’t be lost or accidentally erased. All inputs are protected to +/- 20 volts. The full-featured Configuration & Analysis Software V4.0 (C&A V4.0) is shipped with each system and enables immediate use of the system right out of the box. The form-based setup is extremely intuitive and requires no programming. Once data has been recorded, a single mouse click retrieves data into a builtin spreadsheet. Another mouse click generates a preformatted graph for immediate analysis. C&A Software runs on Windows 95, NT and 3.1.
Applications Laboratory Data Acquisition Materials Testing Field Data Collection Process Monitoring & Control Quality Audit, Parts Measuring Assembly & Calibration Fixturing
Order Information Systems Include: AD128 Logging Unit C&A Software V4.0 9-pin PC Communication Cable 25-pin Sensor Interface Cable Product 5 Volt Analog/Digital 10 Volt Analog/Digital Temperature 5 Volt Analog/Digital with Temperature Temperature/Digital with 5 Volt Analog 10 Volt Analog/Digital with Temperature Temperature/Digital with 10 Volt Analog
9V Battery AC Wall Adapter 1 Year Warranty Free Software Upgrades
Input Types 8 analog, 0 to 5V 16 discrete 8 analog, 0 to 10V 16 discrete 8 temperature 8 discrete 6 analog, 0 to 5V 2 temperature, 14 discrete 6 temperature, 10 discrete 2 analog, 0 to 5V 6 analog, 0 to 10V 2 temperature, 14 discrete 6 temperature, 10 discrete 2 analog, 0 to 10V
Optional Accessories DB25 / Screw Term. Board (3.5”x2”) 6-ft. DB25 - DB25 cable (for use with DB25TRM) Nema 12 Enclosure, stainless steel, hinged, quick-release, 6” x 8” x 4” Thermistor Sensor/Lead, 30k, -10 to 150 °C Thermistor Sensor/Lead, 10k, -30 to 120 °C ** XX = length in feet
Order No. AD128 AD128-10 AD128-T8 AD128-T2 AD128-T6 AD128-10T2 AD128-10T6 Order No. DB25TRM CL25-6 WE128 TP-301-XX** TP-101-XX**
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
Valitec
Model AD128 Stand-Alone Data Acquisition System
SpecificationsOperationI NPUTS1
Analog Input Voltage Range 0 to 5 V (AD128-10: 0 to 10V) Resolution 20mV (AD128-10: 40mV) Absolute Accuracy ± 10mV (AD128-10: ±20mV) Input Bias Current 400 nA Discrete/Digital (up to 10V recommended, 100k pull-ups on 1 thru 8) "Going High" Threshold 3.5 V (Maximum) "Going Low" Threshold 1.0 V (Minimum) Input Bias Current ± 10 µA Temperature Resolution (TP-301) 0.4 °C @ 50 °C Accuracy
(TP-101)0.4 °C @ 25 °C(TP-301)
within ±1.0 °C, 40 to 120 °C
(TP-101)
within ±1.0 °C, 10 to 90 °C
Full-Scale Range
-10 to 150 °C (TP-301)
(better than ±3 °C accuracy)
-30 to 120 °C (TP-101)
Max. Operating Temperature Connector Type
250 °C Standard DB 25-pin
Configure (Setup)
Simple form-based configuration
2Record Information3Retrieve DataStart Stop
D ATA S TORA GE Data Storage Recording Duration Sampling Frequency Data Memory Battery Life
130,000 samples 0.002 seconds to years Fast as 500 Hz, Slow as 99 min. (all channels) 10 years
O PERA TING Power Supply Voltage Current Standby Recording LED Indication (sampling) Battery Life Power Adapter (included) Temperature Operating Storage
Built-in spreadsheet: Graph, Print, Export... 7 to 12 volts (9V batt. / Adapt.) 300µA 4mA (only while sampling) 10mA (can be disabled) Up to 3 months, 9V Alkaline (Up to 6 months, lithium) 110V-9V 200mA AC adapter -10 to 50 degrees Celsius -20 to +70 degrees Celsius
C O M M U N I C A TION RS-232 Interface Baud Rate Connection Data Format
DIMENSIONS W EIGHT4View Graph
For Analysis or Presentation: Copy/Paste, Print, Export...
9600 bps 9-pin female 8 data, no parity, 1 stop bit 5.8" x 3.6" x 1.3" (14.7cm x 9.14cm x 3.3cm) 8 oz. (226 g)
Scale and trigger setup includes predefined sensor profiles.
Example Data Plot