Page 37
Appendix B. Function Codes Function Codes for PC F1 (%VA)
F2 (%VB)
F3 (%VC)
F4 (%VD)
F5 (%VE)
F6 (%VF)
F7 (%VG)
F8 (%VH)
F9 (%VI)
F10 (%VJ)
F11 (%VK)
F12 (%VL)
Cursor Right (/FC)
Cursor Left (/FD)
Cursor Up (/FE)
Cursor Down (/FF)
PgUp (/FG)
PgDn (/FH)
TAB (/FI)
Back Tab (/FJ)
Esc (/FK)
Left Enter (/FL)
Right Ctrl (/FO)
Right Enter (/FM)
Shift Make (/FP)
Ins (/FW)
Ctrl Make (/FQ)
Shift Break (/FS)
Alt Make (/FR)
Ctrl Break (/FT)
Del (/FX)
Alt Break (/FU)
Page B.1
Page 38
Function Codes for Macintosh
F1 (%VA)
F13 (%VM)
Esc (/FK)
F2 (%VB)
F14 (%VN)
Return (/FM)
F3 (%VC)
F15 (%VO)
Option Make (%VP)
F4 (%VD)
Cursor Left (/FD)
Option Break (%VQ)
F5 (%VE)
Cursor Right (/FC)
Control Make (%VR)
F6 (%VF)
Cursor Down (/FF)
Control Break (%VS)
F7 (%VG)
Cursor Up (/FE)
F8 (%VH)
Page down (/FH)
F9 (%VI)
Page up (/FG)
F10 (%VJ)
Ins (/FJ)
F11 (%VK)
Tab (/FI)
F12 (%VL)
Enter (/FL)
Shift Make (%VT)
Shift Break (%VU)
Apple Make (%VV)
Apple Break (%VW)
Page B.2
Page 39
Appendix C. Function Codes for IBM Terminals F1 (%VA)
F2 (%VB)
F3 (%VC)
F4 (%VD)
F5 (%VE)
F6 (%VF)
F7 (%VG)
F8 (%VH)
F9 (%VI)
F10 (%VJ)
F11 (%VK)
F12 (%VL)
F13 (%VM)
F14 (%VN)
F15 (%VO)
F16 (%VP)
F17 (%VQ)
F18 (%VR)
F19 (%VS)
F20 (%VT)
F21 (%VU)
F22 (%VV)
F23 (%VW)
F24 (%VX)
Home (/FA)
End (/FB)
TAB (/FI)
Enter (/FL)
Return (/FM)
Field Exit (/FO)
Field + (/FP)
Field - (/FQ)
Clear(/FR)
Reset (/FV)
Page C.1
Page 40
Appendix D. Setup Menu D.1 Device Selection and Default:
Enter Group 1 Device ID 0
1
2
3
Group Default Device Type
.
30 – Clink-196 00 – IBM PC/XT 01 – IBM PC/AT, PS/2 MOD 40, 60, 80, USB etc. 02 – IBM PS/2 MOD 30 (8086) 25, 56, 70, 90 08 – IBM 3196/3197 09 – IBM 3476/3477 10 – IBM 3191/3192/3270 PC 11 – IBM 3486/3487/3488 13 – IBM 3471/3472(/3179) 15 – IBM 3180 17 – IBM 3151 19 – IBM 5550-5P 20 – IBM 5550-6P 06 – Keyboardless Wedge (PC/AT) 03 – Macintosh (ADB Port) 04 – Serial Wedge 35 – Serial TTL inverted 25 – Terminal Wedge 26 – Wand emulation (Native Output) 07 – Wand emulation (with Code 39 output)
4
5
6
Factory Default 7
8
Exit
9
Page D.1
Page 41
D.2 Beeps and Delays
Enter Group 2
Group Default Beep Tone:
0
1
0 -- None 1 -- Low 2 -- Medium 3 -- High 4 -- Low to High 5 -- High to Low
A1
Interblock Delay: 2
0 -- 10 ms 1 -- 50 ms 2 -- 100 ms 3 -- 500 ms 4 -- 1 seconds 5 -- 3 seconds
A2
3
Intercharacter Delay:
4
0 -- 1 ms 1 -- 5 ms 2 -- 10 ms 3 -- 20 ms 4 – 50 ms 5 -- 100 ms
A3
5
6
7
8
Exit
9
Page D.2
Page 42
D.3 Keyboard Wedge Settings
Enter Group 3
Group Default
Function Code: 0
0 -- Off 1 -- ON
B1
Caps-Lock: 1
0 – Auto Trace(PC/XT,AT) 1 – Lower Case 2 – Upper Case
B2
Language (For PC/XT/AT): 2
3
0-U.S. 1-U.K. 2-Swiss 3-Swedish 4-Spanish
5-Norwegian 6-Italian 7-German 8-French 9-Alt Key Mode
:-Danish
Output of Wand Emulation: 0 - Bar with High/Space with Low 1 - Bar with Low/Space with High
4
B4
Level Duration of Mini Width: 0 - 200us 1 - 600us
5
B3
B5
Polarity of Idle Condition: 0 - Low 1 - High
B6
Pre-define Label: 6
0 - Label 0 1 - Label 1 2 - Label 2 (See “Pre-defined label” section for detail)
B7 7
8
9
Exit
Page D.3
Page 43
D.4 RS232 Settings
Enter Group 4
Group Default Baud Rate:
0
0 -- 300 1 -- 600 2 -- 1200 3 – 2400
4 – 4800 5 – 9600 6 – 19200 7 – 38400
C1
Parity: 1
0 – Even 1 – Odd 2 – Mark
3 -- Space 4 -- None
C2
Data Bit: 2
0–7 1–8
C3
Handshaking (for serial wedge): 3
0 -- Ignore 1 – RTS Enable at Power up 2 – RTS Enabled in Communication
C4
ACK/NAK ( for serial wedge ): 4
0 – Off 1 – On
C5
BCC Character ( for serial wedge ): 0 – Off 1 – On
5
6
C6
Time Out( for serial wedge): 0 -- 1 sec 1 – 3 sec 2 – 10sec 3 – Unlimited
C7
Data direction(for Terminal Wedge): 7
0 – Send to Host 1 – Send to Host and Terminal 2 – Send to Terminal
C8
8
Exit
9
Page D.4
Page 44
D.5 Scanner Port:
Enter Group 5
0
1
2
3
4
Group Default Terminator: 0 - Enter (CR/LF) 2, Return (LF) Code ID: 0 – None
1 - Field Exit (CR) 3 - None
D1
1 – User Define D2
2 – Default Set Define Code ID: 00–Code 39 Full ASCII 11–MSI Code 12– EAN128 01–Code 39 Standard 13–Code32 (Italian 02–EAN-13 harmacy) 03–UPC-A 14–Delta Code 04–EAN-8 15–Label Code 05–UPC-E 16–Plessey Code 06–Interleaved 2 of 5 17– Code 11(Special) 07–Codabar 18–China Postal code 08–Code 128 (Toshiba Code) 09–Code 93 10–Standard 2 of 5
D3 Scan two digits to choose a code, then scan a char. From full ASCII table to define ID.
Double Verification: 0 – Off 1 – On
D4
Scanning Mode: 5
0 – Trigger Mode 1– Flashing Mode
D5
Label Type: 6
0 – Positive 1 – Positive and Negative
D6
Preamble
7 PP 8
Postamble
9
Scan ‘PP\OO’ for Pre\Postamble. Scan characters from Full ASCII char or Function
OO
Page D.5
Exit
Page 45
D.6 Code 39 / I 2 of 5 / S 2 of 5 / Code 32 / EAN128
Enter Group 6
Group Default Code 39:
0
1
2
0/1--Disable/Enable. 2/3--Full ASCII/ Standard. 4--Check Digit (CD) Calculate & Send. 5--CD Calculate, not send. 6 --CD not Calculate. 7/8 -- Send/No Send Start/Stop 0 - 48 -- Min length 0 / Max length 48 I 2 of 5 (ITF): 0/1--Disable/Enable 2/3--Fix Length On/Off (by first three reads) 4--Check Digit (CD) Calculate & Send 5--CD Calculate, not send. 6--CD not Calculate 7--First Digit Suppressed. 8--Last Digit Suppressed 9 -- Not Suppressed 2 - 64 -- Min length 10 / Max length 64
F1
F2
S 2 of 5/China Postal Code(Toshiba Code): 3
0/1--Disable/Enable 2/3 -- Fix Length On/Off (by first three reads) 4--Check Digit (CD) Calculate & Send 5--CD Calculate, not send. 6--CD not Calculate 1 - 48 -- Min length 4 / Max length 48
F3
Code 32(Italian pharmacy): 4
0/1 -- Disable/Enable 2/3 -- Leading Character Send / No Send 4/5 -- Tailing Character Send / No Send
F4
Reserve 5
6
7
8
F5
UCC/EAN 128: 0/1 - disable/Enable 2/3 - Code ID disable/Enable Note: If EAN128 be disabled, the EAN128 labels will be decoded as Code 128
F6
Define the EAN128 Fields separator: Scan a ASCII code in full ASCII code chart to select a new definition of Func1 Min Length
F7
MM
Max Length 9
Exit NN
Page D.6