Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 6

Hand Held Scanner User's Manual, pages 37 to 45

Pages 37 to 45 of 54

The original document is the PDF (318 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Unitech MS300

Page 37

Appendix B. Function Codes Function Codes for PC F1 (%VA)

F2 (%VB)

F3 (%VC)

F4 (%VD)

F5 (%VE)

F6 (%VF)

F7 (%VG)

F8 (%VH)

F9 (%VI)

F10 (%VJ)

F11 (%VK)

F12 (%VL)

Cursor Right (/FC)

Cursor Left (/FD)

Cursor Up (/FE)

Cursor Down (/FF)

PgUp (/FG)

PgDn (/FH)

TAB (/FI)

Back Tab (/FJ)

Esc (/FK)

Left Enter (/FL)

Right Ctrl (/FO)

Right Enter (/FM)

Shift Make (/FP)

Ins (/FW)

Ctrl Make (/FQ)

Shift Break (/FS)

Alt Make (/FR)

Ctrl Break (/FT)

Del (/FX)

Alt Break (/FU)

Page B.1

Page 38

Function Codes for Macintosh

F1 (%VA)

F13 (%VM)

Esc (/FK)

F2 (%VB)

F14 (%VN)

Return (/FM)

F3 (%VC)

F15 (%VO)

Option Make (%VP)

F4 (%VD)

Cursor Left (/FD)

Option Break (%VQ)

F5 (%VE)

Cursor Right (/FC)

Control Make (%VR)

F6 (%VF)

Cursor Down (/FF)

Control Break (%VS)

F7 (%VG)

Cursor Up (/FE)

F8 (%VH)

Page down (/FH)

F9 (%VI)

Page up (/FG)

F10 (%VJ)

Ins (/FJ)

F11 (%VK)

Tab (/FI)

F12 (%VL)

Enter (/FL)

Shift Make (%VT)

Shift Break (%VU)

Apple Make (%VV)

Apple Break (%VW)

Page B.2

Page 39

Appendix C. Function Codes for IBM Terminals F1 (%VA)

F2 (%VB)

F3 (%VC)

F4 (%VD)

F5 (%VE)

F6 (%VF)

F7 (%VG)

F8 (%VH)

F9 (%VI)

F10 (%VJ)

F11 (%VK)

F12 (%VL)

F13 (%VM)

F14 (%VN)

F15 (%VO)

F16 (%VP)

F17 (%VQ)

F18 (%VR)

F19 (%VS)

F20 (%VT)

F21 (%VU)

F22 (%VV)

F23 (%VW)

F24 (%VX)

Home (/FA)

End (/FB)

TAB (/FI)

Enter (/FL)

Return (/FM)

Field Exit (/FO)

Field + (/FP)

Field - (/FQ)

Clear(/FR)

Reset (/FV)

Page C.1

Page 40

Appendix D. Setup Menu D.1 Device Selection and Default:

Enter Group 1 Device ID 0

1

2

3

Group Default Device Type

.

30 – Clink-196 00 – IBM PC/XT 01 – IBM PC/AT, PS/2 MOD 40, 60, 80, USB etc. 02 – IBM PS/2 MOD 30 (8086) 25, 56, 70, 90 08 – IBM 3196/3197 09 – IBM 3476/3477 10 – IBM 3191/3192/3270 PC 11 – IBM 3486/3487/3488 13 – IBM 3471/3472(/3179) 15 – IBM 3180 17 – IBM 3151 19 – IBM 5550-5P 20 – IBM 5550-6P 06 – Keyboardless Wedge (PC/AT) 03 – Macintosh (ADB Port) 04 – Serial Wedge 35 – Serial TTL inverted 25 – Terminal Wedge 26 – Wand emulation (Native Output) 07 – Wand emulation (with Code 39 output)

4

5

6

Factory Default 7

8

Exit

9

Page D.1

Page 41

D.2 Beeps and Delays

Enter Group 2

Group Default Beep Tone:

0

1

0 -- None 1 -- Low 2 -- Medium 3 -- High 4 -- Low to High 5 -- High to Low

A1

Interblock Delay: 2

0 -- 10 ms 1 -- 50 ms 2 -- 100 ms 3 -- 500 ms 4 -- 1 seconds 5 -- 3 seconds

A2

3

Intercharacter Delay:

4

0 -- 1 ms 1 -- 5 ms 2 -- 10 ms 3 -- 20 ms 4 – 50 ms 5 -- 100 ms

A3

5

6

7

8

Exit

9

Page D.2

Page 42

D.3 Keyboard Wedge Settings

Enter Group 3

Group Default

Function Code: 0

0 -- Off 1 -- ON

B1

Caps-Lock: 1

0 – Auto Trace(PC/XT,AT) 1 – Lower Case 2 – Upper Case

B2

Language (For PC/XT/AT): 2

3

0-U.S. 1-U.K. 2-Swiss 3-Swedish 4-Spanish

5-Norwegian 6-Italian 7-German 8-French 9-Alt Key Mode

:-Danish

Output of Wand Emulation: 0 - Bar with High/Space with Low 1 - Bar with Low/Space with High

4

B4

Level Duration of Mini Width: 0 - 200us 1 - 600us

5

B3

B5

Polarity of Idle Condition: 0 - Low 1 - High

B6

Pre-define Label: 6

0 - Label 0 1 - Label 1 2 - Label 2 (See “Pre-defined label” section for detail)

B7 7

8

9

Exit

Page D.3

Page 43

D.4 RS232 Settings

Enter Group 4

Group Default Baud Rate:

0

0 -- 300 1 -- 600 2 -- 1200 3 – 2400

4 – 4800 5 – 9600 6 – 19200 7 – 38400

C1

Parity: 1

0 – Even 1 – Odd 2 – Mark

3 -- Space 4 -- None

C2

Data Bit: 2

0–7 1–8

C3

Handshaking (for serial wedge): 3

0 -- Ignore 1 – RTS Enable at Power up 2 – RTS Enabled in Communication

C4

ACK/NAK ( for serial wedge ): 4

0 – Off 1 – On

C5

BCC Character ( for serial wedge ): 0 – Off 1 – On

5

6

C6

Time Out( for serial wedge): 0 -- 1 sec 1 – 3 sec 2 – 10sec 3 – Unlimited

C7

Data direction(for Terminal Wedge): 7

0 – Send to Host 1 – Send to Host and Terminal 2 – Send to Terminal

C8

8

Exit

9

Page D.4

Page 44

D.5 Scanner Port:

Enter Group 5

0

1

2

3

4

Group Default Terminator: 0 - Enter (CR/LF) 2, Return (LF) Code ID: 0 – None

1 - Field Exit (CR) 3 - None

D1

1 – User Define D2

2 – Default Set Define Code ID: 00–Code 39 Full ASCII 11–MSI Code 12– EAN128 01–Code 39 Standard 13–Code32 (Italian 02–EAN-13 harmacy) 03–UPC-A 14–Delta Code 04–EAN-8 15–Label Code 05–UPC-E 16–Plessey Code 06–Interleaved 2 of 5 17– Code 11(Special) 07–Codabar 18–China Postal code 08–Code 128 (Toshiba Code) 09–Code 93 10–Standard 2 of 5

D3 Scan two digits to choose a code, then scan a char. From full ASCII table to define ID.

Double Verification: 0 – Off 1 – On

D4

Scanning Mode: 5

0 – Trigger Mode 1– Flashing Mode

D5

Label Type: 6

0 – Positive 1 – Positive and Negative

D6

Preamble

7 PP 8

Postamble

9

Scan ‘PP\OO’ for Pre\Postamble. Scan characters from Full ASCII char or Function

OO

Page D.5

Exit

Page 45

D.6 Code 39 / I 2 of 5 / S 2 of 5 / Code 32 / EAN128

Enter Group 6

Group Default Code 39:

0

1

2

0/1--Disable/Enable. 2/3--Full ASCII/ Standard. 4--Check Digit (CD) Calculate & Send. 5--CD Calculate, not send. 6 --CD not Calculate. 7/8 -- Send/No Send Start/Stop 0 - 48 -- Min length 0 / Max length 48 I 2 of 5 (ITF): 0/1--Disable/Enable 2/3--Fix Length On/Off (by first three reads) 4--Check Digit (CD) Calculate & Send 5--CD Calculate, not send. 6--CD not Calculate 7--First Digit Suppressed. 8--Last Digit Suppressed 9 -- Not Suppressed 2 - 64 -- Min length 10 / Max length 64

F1

F2

S 2 of 5/China Postal Code(Toshiba Code): 3

0/1--Disable/Enable 2/3 -- Fix Length On/Off (by first three reads) 4--Check Digit (CD) Calculate & Send 5--CD Calculate, not send. 6--CD not Calculate 1 - 48 -- Min length 4 / Max length 48

F3

Code 32(Italian pharmacy): 4

0/1 -- Disable/Enable 2/3 -- Leading Character Send / No Send 4/5 -- Tailing Character Send / No Send

F4

Reserve 5

6

7

8

F5

UCC/EAN 128: 0/1 - disable/Enable 2/3 - Code ID disable/Enable Note: If EAN128 be disabled, the EAN128 labels will be decoded as Code 128

F6

Define the EAN128 Fields separator: Scan a ASCII code in full ASCII code chart to select a new definition of Func1 Min Length

F7

MM

Max Length 9

Exit NN

Page D.6