Page 10

3.2

Understanding the Operating Parameters Device Type You will need to select the device type to “Serial Interface” from Appendix A, Group 1 of Appendix D, or the following label.

Serial Interface Baud Rate, Parity and Data Bit: These parameters set the scanner’s communication protocol that must be matched by the host. The default setting for the serial interface is 9600 baud rate, none parity, and 8 data bit. * Baud Rate can be 300, 600, 1200, 2400, 4800, 9600, 19200, or 38400 bps. * Parity can be even, odd, space, mark, or none. * Data Bit can be 7 or 8 bit long. The scanner may not support settings with Data Bit as 7 and Parity as none combination. Such combination is treated as 7 data bits with MARK parity. Handshaking: The scanner supports CTS/RTS handshaking as an option. The hardware handshaking is supported on character-by-character basis. During the communication, the scanner will stop sending data until the CTS is valid within time specified by the Time Out parameter. During this time-out waiting period: -- If CTS is valid, communication resumes. -- If CTS is not valid, the scanner sounds an error beep and discards the current buffered data.

Page 9

Page 11

BCC Character: BCC check character is calculated for entire data stream by using “Exclusive OR ” method. It is sent after data stream for data verification. Time Out: You can adjust the Time Out duration for handshaking and ACK/NAK protocol to fit applications.

3.3 Serial TTL This scanner supports serial TTL interface, which follows the RS232 communication data format but with TTL voltage output ranged from 0V to 5V.

Page 10

Page 12

Chapter 4 4.1

Terminal Interface

Installation To install the scanner as a terminal interface, you need a DB25 RS232 cable, a terminal wedge “Y” cable and an AC adapter. See Figure 3 for reference. Original Cable Terminal male female

"Y" Cable

SCANNER

Host AC adaptor

RS232 Cable

Figure 3. Installing as a Terminal Wedge

Installation procedures: 1) Power off the terminal and unplug the communication cable at terminal side. 2) Install the interface cable as shown in Figure 3. The “Y” cable provided in Figure 3 is for terminals with female connector on communication port. If there is a male connector on your terminal, you need a converter to change that male to female and another converter to change the female to male on host connector. 3) When the scanner is powered, a long beep sound indicates that the scanner is ready to use.

Page 11

Page 13

4) If the scanner has not been configured yet, you need to select “Terminal Wedge” device number from Appendix A, Group 1 of Appendix D, or the following label.

Terminal Wedge

4.2

Understanding the Operating Parameters Baud Rate, Parity and Data Bit: These parameters set the scanner’s communication protocol which must be matched the same setting by the host. The default setting for the terminal interface is 9600 baud rate, none parity, and 8 data bit. * Baud Rate can be 300, 600, 1200, 2400, 4800, 9600, 19200, or 38400 bps. * Parity can be even, odd, space, mark, or none. * Data Bit can be 7 or 8 bit long. The scanner may not support settings with Data Bit as 7 and Parity as none combination. Such combination is treated as 7 data bits with MARK parity. Data Direction: This setting is only for the terminal wedge and corresponds to the terminal communication mode. If the terminal has: * "Full Duplex" mode, set the data direction to "Send to Host". * "Half Duplex" mode, set to "Send to Host and Terminal". * "Block" mode, set to "Send to Terminal".

Page 12

Page 14

Chapter 5 5.1

Wand Emulation

Installation Figure 4 shows how a wand emulation scanner is installed to a data collection terminal. User needs to pay attention to the scanner pinout that should be the same as specified by the terminal.

SCANNER

Figure 4. Installed as a Wand Emulation Scanner

5.2

Understanding the Operating Parameters Code 39 Output: When device number “07” is selected, the scanner is set as wand emulation with Code 39 output. In this configuration, the scanner always outputs data with Code 39 symbology no matter what symbology of the label it scans. You may scan the following label if this setting matched your application.

Code39 Wand Emulation

Native Output: When device number “26” is selected, the scanner is set to wand emulation with native output. That means the scanner outputs data with both the same contents and symbology as the label represents.

Page 13

Page 15

Output of Wand Emulation: (Appendix D, 3) Select one of the two choices for the polarity of data output: * High level for bar (black) and low level for space (white). * High level for space (white) and low level for bar (black). Level Duration of Minimum Width: (Appendix D, 3) Determine the minimum time duration for bar or space either 200 us or 600 us. Longer time means slower movement of the wand scanner. Polarity of Idle: (Appendix D, 3) Polarity of idle (without scanning) can be selected either low or high.

Page 14

Page 16

Chapter 6

Setup

The scanner interface can be configured to fit the user's specific application. All configuration parameters are stored in a non-volatile memory, which is retained even if power is lost.

6.1 Bar Code Menu Setup The setup menu in Appendix D contains eight groups: * Group 1: Device selection. * Group 2: Beep and delay. * Group 3: Keyboard and Wand Emulation. * Group 4: RS-232 Settings * Group 5: Scanner port. * Group 7: Code 39, I 2 of 5, S 2 of 5 and Code 32. * Group 8: Code 128, Code 93, Code 11, Codabar, and MSI. * Group 9: UPC/EAN, and Delta Distance Code. * Group 10: Data Editing. * Group 11: Dump setup. 6.1.1 Setup Procedures: For most parameters, proceed the following steps for the setting: 1) Locate a group that contains the parameter to be changed. 2) Scan the "Enter Group #" label to enter setup mode. The green LED on the scanner will flash to indicate that setup is in progress. 3) Scan the label (on right hand side) representing the parameter to be changed. (For example, B1 label) 4) Scan the labels (number) representing the desired parameter value. (For example, 05, scan “0” and “5” labels.) 5) Repeat step 3 and 4, if necessary, to change the parameters in the same group. 6) Scan "Exit" label to end the group setup. The scanner will make two beeps to end the setup.

Page 15

Page 17

6.1.2 Bar Code Length Setting: The following example illustrates how to set Code 39 with a minimum length of 5 and a maximum length of 20: * Scan “Enter Group 5”. * Scan “F1” to select Code 39. * Scan “MIN LENGTH” to enter minimum length setting. * Scan “0” and “5” to select length 5. * Scan “MIN LENGTH” to end minimum length setting. * Scan “MAX LENGTH” to enter maximum length setting. * Scan “2” and “0” to select length 20. * Scan “MAX LENGTH” to end maximum length setting. * Scan “Exit” to end setup. 6.1.3 Code ID Setting: Each bar code symbology supported by the scanner has a default ID character defined as below: (If you don’t know what is the label that you’re scanning, you may use this feature to identify.) Symbology UPC-A UPC-E EAN-13 EAN-8 I 2 of 5 S 2 of 5 Code 39 Codabar Code 93 Code 128 UCC/EAN128 MSI Code 32 Delta Code Plessey Code Label Code IV, V China Postal Code

Pre-Defined A E F FF I H M N L K ]C1 O T D P B C

Page 16

Page 18

Those ID characters can be redefined through setup menu. The following example shows how to set Code 93 with ID ‘O’ and Code 128 without ID: * Scan “Enter Group 3”. * Scan “D2” to select Code ID. * Scan “1” for "Yes". * Scan “D3” to define IDs. * Scan “0” and “9” for selecting Code 93. * Scan “O” from Full ASCII Table for new ID. * Scan “0” and "8" to select Code 128. * Scan “NULL” character from Full ASCII Table for none ID. * Scan “Exit” to end setup. 6.1.4 Preamble (Prefix) and Postamble (Suffix): Preamble, the scanner adds the start of text characters before the input data. Postamble, the scanner adds end of text characters after the input data. The following is an example to set ‘STX’ as preamble and ‘ETX’ as postamble: * Scan “Enter Group 3”. * Scan “PP” to start preamble setting. * Scan ‘STX’ character from Full ASCII Table. * Scan “PP” to end preamble setting. * Scan “OO” to start postamble setting. * Scan ‘ETX’ from Full ASCII Table. * Scan “OO” to end postamble setting. * Scan “Exit”. 6.1.5 Predefined Labels The scanner provides three special labels encoded as “/FY”, “/FZ” and “/F-” in Code 39 format. The output from these labels can be defined through the setup menu. The definition of the labels share the same space with “Edit Formula definition”(See “Output Data Editing”), so you can only use either one of the function. Label 0

Label 1

Label 2

/ FY

/ FZ

/ F-

Page 17