Page 31
6. Set up the output transmission parameters Output to host system - RS-232 RTS/CTS hardware protocol Not Active (*)
Active
Inter-character delay No Delay (*)
10 ms
Postamble Carriage Return + Line Feed (*)
Carriage Return
Line Feed
No Postamble
MB/NX/IG/00/E/961031
6-5
Page 32
6. Set up the output transmission parameters Output to host system - RS-232 Advanced parameters - MicroBar NX Reference Manual baud rate - 75 - 150 - 300 - 600 - 1200 - 2400 - 4800 - 38400 parity - mark - space hardware/software protocols timeout - 1000 ms (*) - unlimited - user-defined 1 to 2500 ms ENQ (Hex 05) - not used (*) - ENQ (HEX 05) - user-defined ACK (Hex 06) - not used (*) - ACK (HEX 06) - user-defined NAK (Hex 15) - not used (*) - NAK (HEX 15) - user-defined XON/XOFF software protocol - not active (*) - active RTS/CTS hardware protocol - low RTS idle (*) - high RTS idle LRC (longitudinal redundancy check) - not active (*) - active preamble - no preamble - user-defined postamble - user-defined default code marks - not transmitted (*) - transmitted - user-defined AIM symbology identifiers - not transmitted (*) transmitted inter-character delay - user-defined 1 to 999 ms inter-message delay - none (*) - user-defined 1 to 999 ms
6-6
MB/NX/IG/00/E/961031
Page 33
7
Set up the data input parameters data input devices devices used to enter data through the MicroBar NX to the host system: • pen barcode readers
• laser/CCD barcode readers in wand/laser emulation
• undecoded magstripe readers
•
RS-232 input devices - electronic scales, barcode readers, magstripe readers, . . .
See section 3, Connect the data input devices to the MicroBar NX.
Depending on the type of input device you connect to the MicroBar NX, you can customize the data input parameters using one or more of the following parameter sets provided in the appendix: Appendix A - Symbology parameters for barcode readers Appendix B - Laser scanner parameters Appendix C - Magstripe parameters Appendix D - RS-232 input device data transmission parameters
Your MicroBar NX setup is now complete! If you have any problems using your MicroBar NX, refer to Appendix F for help.
MB/NX/IG/00/E/961031
7-1
Page 34
7. Set up the data input parameters
7-2
MB/NX/IG/00/E/961031
Page 35
A
Symbology parameters for barcode readers symbology barcode type or "family" - Code 39, UPC and EAN are examples of common symbologies
This appendix provides the activation codes and some common parameter settings for the different symbologies supported. The full set of available symbology parameter options is provided in the MicroBar NX Reference Manual (Ð Symbologies). Factory default settings are indicated by an asterisk (*). Symbology default settings ..........................................................................A-2 Ames Code...................................................................................................A-3 Codabar........................................................................................................A-4 Code 11 ........................................................................................................A-5 Code 39 (*) ...................................................................................................A-6 Code 93 ........................................................................................................A-9 Code 128 / EAN 128 ..................................................................................A-10 Interleaved 2 of 5........................................................................................A-11 Matrix 2 of 5................................................................................................A-14 MSI Code....................................................................................................A-15 Plessey Code .............................................................................................A-16 Standard 2 of 5 ...........................................................................................A-17 Telepen ......................................................................................................A-20 UPC/EAN code families (UPC-A, UPC-E, EAN-8, EAN-13) (*) ..................A-21 If your application uses a ScanPlus as an input device (wand or laser emulation), the same symbologies (and code lengths if applicable) must be activated for the ScanPlus and the MicroBar NX. Disconnect the ScanPlus to make sure that ScanPlus Transparent Configuration Mode is disabled before you configure the ScanPlus.
MB/NX/IG/00/E/961031
A-1
Page 36
A. Symbology parameters for barcode readers Symbology default settings When you install your MicroBar NX for the first time, Code 39 and UPC/EAN are preselected by default and all the symbology parameters are set to their factory default settings. The symbology default settings are global factory defaults - they are independent of the different symbology activation codes. To optimize the performance of your MicroBar NX and to ensure trouble-free decoding, do not select symbologies that you do not need - deactivate the Code 39 and UPC/EAN default symbologies if you do not need to use them.
Resetting symbology default settings If you want to reset all the default symbology settings, you can scan the Reset Factory Defaults bar code provided in Appendix F, but you will then have to completely reconfigure your MicroBar NX. In most cases, it is easier to perform the following symbology reset procedure. Keep a list of your custom settings - this will be useful if you have to perform a reset.
1. Scan the Disable All Symbologies bar code: Disable All Symbologies
2. Select the activation codes for the symbologies you want to read. 3. Customize the symbology parameter settings if required.
The Disable All Symbologies code deactivates all the symbologies activated. If you want to deactivate individual symbologies, use the Not Active codes for each symbology. Disable All Symbologies does not reset the individual parameter settings for each symbology. When you reactivate a symbology, you recover the parameter settings stored in memory for that symbology when it was disabled.
A-2
MB/NX/IG/00/E/961031
Page 37
A. Symbology parameters for barcode readers Ames Code Activation Not Active (*)
Active
MB/NX/IG/00/E/961031
A-3
Page 38
A. Symbology parameters for barcode readers Codabar Activation Not Active (*)
Active
Common parameter settings - Start/stop Not Transmitted (*)
a, b, c, d
Advanced parameters - MicroBar NX Reference Manual start/stop CLSI library system check digit (AIM recommendation) concatenation -
A-4
A, B, C, D a, b, c, d / t, n, *, e DC1, DC2, DC3, DC4 not active (*) active not used (*) checked and transmitted checked but not transmitted read adjacent codes as single code (*) read single codes only read adjacent codes if stop 1 = start 2 ABC (American Blood Commission) transmit single and concatenated codes (*) transmit concatenated codes only
MB/NX/IG/00/E/961031
Page 39
A. Symbology parameters for barcode readers Code 11 Activation Not Active (*)
Active
Common parameter settings - Check digits 1 Check Digit (*)
2 Check Digits
Checked And Transmitted (*)
Checked But Not Transmitted
MB/NX/IG/00/E/961031
A-5
Page 40
A. Symbology parameters for barcode readers Code 39 (*) Activation Active (*)
Not Active
Standard 43 Characters (*)
Full ASCII
Common parameter settings - Start/stop Not Transmitted (*)
Transmitted
A-6