Page 203

Data Transfer

9

Note – Only points with grid coordinates can be selected and transferred. If the job does not have a projection and datum transformation specified, then GPS points cannot be transferred. Deleted points, and any points stored as polar vectors from a deleted point, cannot be transferred either. 14. You are prompted to initiate receiving on the instrument that you are sending data to. For more information about receiving data, refer to the manual for the receiving device. When the other device is ready to receive, press the data. The data is transferred.

y to send

Receiving ASCII Data from an External Device To receive ASCII data from an external device: 1.

Select Files/Import/Export / Receive ASCII data. Figure 9.7 shows the screen that appears.

Figure 9.7

2.

Receive ASCII Data screen

Use the File format field to specify the device that you want to receive data from.

Trimble Survey Controller Reference Manual Volume 1

173

Page 204

9

Data Transfer

3.

If the File format field is set to Generic (CSV), Trimble DC v3, or SDR33 DC, the Receive from field appears. Set the field to PC card or External device depending on where you want the file to be sent. If you choose PC card, the Port details fields disappear. Note – The PC card option only appears if you have a PC card inserted.

4.

Set the Port details/Controller port field to Top or Bottom depending on which TSC1 port is to be used for the transfer.

5.

Set the Baud rate and Parity fields to match the corresponding parameters on the device that the Trimble Survey Controller software is communicating with. Note – If the File format field is set to Generic (CSV), set the baud rate correctly on the external device. If appropriate, set the flow control (xon/xoff) as well. If you are transferring a .dc file, the Checksum field appears. Set it to On if you want the Trimble Survey Controller software to validate the checksum when the file is transferred. You have no control over the file format when transferring the following formats: Geodimeter (Area), SDR33, TDS, Topcon (GTS-7), Topcon (FC-5), Zeiss (R5), Zeiss (Rec E/M5), or Zeiss (Rec500). The fields used for receiving from these devices are described below.

C

17 4

Warning – When receiving data from a device that does not include a units setting as part of its file, make sure that the Trimble Survey Controller software file uses the units setting of that device. If you are not sure whether the device file includes a units setting, set the Trimble Survey Controller software file to the same units as the device.

Trimble Survey Controller Reference Manual Volume 1

Page 205

Data Transfer

9

The Point name field has four possible settings depending on the file format you are using: –

Unchanged - uses the point names in the data that is being received.

–

Truncate left - shortens point names to 16 characters, starting from the left.

–

Truncate right - shortens point names to 16 characters, starting from the right. Trimble Survey Controller software point names have a maximum of sixteen characters, but some points received from other devices can exceed this. If point names have 16 characters or more, choose either Truncate left or Truncate right - the names are not affected.

–

Auto-generate causes two extra fields to appear: Use Start point name to specify a name for the first point received. Use Auto point step size to define the increment or decrement value applied to the Start point value to generate point names for subsequently transferred points.

Use the Point code field to specify the data that is used in the Code field for a point when it is transferred to the Trimble Survey Controller software:

6.

–

Select Use point code to use the point code provided in the data being transferred.

–

Select Use point name to use the point name provided in the data being transferred.

The setting in the File Format field (see Step 2) determines what you do next. –

If the File format field is set to Generic (CSV), for example, you can specify the format of the data that is received. Five fields appear: Point name, Point code, Northing, Easting, and Elevation. Trimble Survey Controller Reference Manual Volume 1

175

Page 206

9

Data Transfer

Using the options provided, select a position for each field. Select the Unused option if a particular value is not present in the file being received. If you set the fields as follows, for example: Point name

Field 1

Point code

Unused

Northing

Field 2

Easting

Field 3

Elevation

Field 4 the Trimble Survey Controller software inputs a file containing data in the format: Point name, Northing, Easting, Elevation. –

7.

If the File format field is set to Trimble DC v3 or SDR33 DC and you have a PC card inserted, the New job location field appears. Select PC card or Main memory.

When the format details are complete, press

_

.

If you are transferring points (not a .dc file), the Select job to receive into list appears. Select the job that the data is to be stored in. 8.

The Trimble Survey Controller software prompts you to initiate sending on the external device. For more information about sending data, refer to the manual for the sending device. When sending is initiated, the Trimble Survey Controller software starts to receive data and a progress bar appears. When the transfer is complete, the Trimble Survey Controller software automatically terminates the operation and saves the received data. If it is clear that the transfer is complete but the operation has not been terminated, press [Esc] .

17 6

Trimble Survey Controller Reference Manual Volume 1

Page 207

Data Transfer

9

The following message appears: Transmission interrupted. What would you like to do now?

J | a

Do one of the following:

9.3.3

– to return the Trimble Survey Controller Press software to receive mode.

– to terminate the operation and save any Press received data to the current job.

– to terminate the operation and discard any Press received data.

Transferring Data to and from a Leica Instrument Using the PC Card You can transfer data between the Trimble Survey Controller software and Leica instruments that use PC cards (the Leica TC 1100, for example). The PC card must be a Type I or Type II ATA format PC card. Transferring data to a Leica instrument using the PC card To transfer data to a Leica instrument, do the following: 1.

Create a CSV file on the PC card. For information about how to do this, see Transferring ASCII Data to and from the PC Card, page 163. This file is stored in the root directory on the PC card.

2.

Remove the PC card from the TSC1 and insert it into the Leica instrument.

3.

From the main menu on the Leica instrument, select Data conversion.

4.

Press the CONF softkey and configure the output file settings. Use the same settings as in the Trimble Survey Controller software.

Trimble Survey Controller Reference Manual Volume 1

177

Page 208

9

Data Transfer

Note – Set the Search extens. field to CSV. If you do not, the CSV files will not be available for selection in the Source File field. Also, set the Separator field to Comma. Press

O

.

5.

Set Source Path to A:\.

6.

In the Source File field, select the CSV file on the PC card.

7.

Set the Output Path to A:\GSI. For the Leica instrument to read the file it must be in the GSI directory.

8.

Key in the output file name. (Make sure that the file extension is GSI,)

9.

Set the Format to GSI 16.

10. Press the Go softkey. The CSV file is then converted to a GSI file and stored in the GSI directory on the PC card. Transferring data from a Leica instrument using the PC card To transfer data from a Leica instrument do the following: 1.

Check that the Leica instrument has a PC card inserted.

2.

From the main menu on the Leica instrument, select Data conversion.

3.

Press the CONF softkey and configure the output file format. Use the same settings as in the Trimble Survey Controller software. Note – Set the Search extens. field to GSI. If you do not, the GSI files will not be available for selection in the Source File field. Also, set the Separator field to Comma.

17 8

O

.

4.

Press

5.

Set Source Path to A:\GSI

Trimble Survey Controller Reference Manual Volume 1

Page 209

Data Transfer

9

6.

In the Source File field select the job to export coordinates from.

7.

Set the Output Path field to A:\ . The Trimble Survey Controller software only reads CSV files that are in the root directory.

8.

Key in the output file name. Make sure that it has the extension CSV.

9.

Set the Format field to ASCII.

10. Press the GO softkey (F1). The GSI file is converted to a ASCII CSV file and is stored in the root directory on the PC card. Note – The Leica instrument does not transfer point codes when it converts a GSI file to an ASCII file. 11. Remove the PC card from the Leica instrument and insert it into the TSC1. 12. Transfer the coordinates into a job on the Trimble Survey Controller software. For information about how to do this, see To transfer a file from the PC card, page 166.

Trimble Survey Controller Reference Manual Volume 1

179

Page 210

9

18 0

Data Transfer

Trimble Survey Controller Reference Manual Volume 1