Page 159
Survey Styles 7.5.2
7
Radios If you are using an RTK survey type to provide real-time positions, you need to specify the type of radios used to provide the radio link between the base station and the rover. Specify the type of radio in use at both the base and rover receivers. For information about configuring a Survey Style to use real-time corrections provided by WAAS instead of a radio, see Differential Survey Styles, page 143. To specify the radio used: 1.
Select Rover radio.
2.
In the Type field, select your radio from the list. The options are TRIMTALK 450, TRIMTALK 900, TRIMTALK 450S, TRIMMARK Rover, TRIMCOMM, Trimble internal, Pacific Crest, Satel, Clarion or Cellular modem. Note – If your radio does not appear on the list, select Custom radio and define the receiver port, the baud rate, and the parity. If you select Cellular modem, do the following: –
B
In the Init string field, enter the command that the Trimble Survey Controller software sends to the modem to instruct it to start communication. This step is optional.
Tip – For some cellular modems you must enter a Personal Identification Number (PIN). Usually the command is as follows: AT+CPIN=**** (where **** is the PIN) If using a PIN, add the command to the end of the value in the Init string field.
–
In the Hang up field, enter the command that the Trimble Survey Controller software sends to the modem to instruct it to end communication.
Trimble Survey Controller Reference Manual Volume 1
129
Page 160
7
Survey Styles
–
In the Dial prefix field, enter the command that the Trimble Survey Controller software sends to the modem to instruct it to dial a number.
–
In the Number to dial field, enter the phone number of the base station modem. Note – In the Number to dial field, use the character “,” to send a short delay. You can use this to separate the area code from the phone number.
–
In the Dial suffix field, enter the command that the Trimble Survey Controller software sends to the modem after it has dialled the number. This step is optional. The Dial prefix, Number to dial, and Dial suffix are concatenated and sent to the modem.
–
In the Post connect field, enter the information that the rover modem provides to the base system when connection has been made. For example, a log-in name and password. This step is optional. Note – In the Post connect field, use the character “,” to send a carriage return and a short delay (3 seconds) to the base system. You can use this to separate a log-in name and password.
3.
Select Base radio.
4.
In the Type field, select your radio from the list. The options are TRIMTALK 450, TRIMTALK 900, TRIMTALK 450S, TRIMMARK, TRIMCOMM, Pacific Crest, Satel, Clarion, Custom radio and Cellular modem. If you select Cellular modem, do the following: –
13 0
In the Init string field, enter the command that the Trimble Survey Controller software sends to the modem to instruct it to start communication. For the base, this command must leave the modem in auto-answer mode. Alternatively, you can set the auto-answer mode separately.
Trimble Survey Controller Reference Manual Volume 1
Page 161
Survey Styles
–
7
In the Hang up field, enter the command that the Trimble Survey Controller software sends to the modem to instruct it to end communication.
If you are using a cellular modem, CTS is always enabled for the base modem. For more information about CTS, see the next section. For more information about radios, see Radio Solutions, page 288. Ready To Send (RTS) and Clear To Send (CTS) If you select Base radio and set the Type field to Custom radio you can also do the following:
C
• enable Clear To Send (CTS)
• set the CTS delay
Warning – Do not enable CTS unless the receiver is connected to a radio that supports CTS.
The GPS Total Station 4700 and 4800 receivers support RTS/CTS flow control when you enable CTS. If you are using a GPS Total Station 4700 or 4800 receiver, use receiver firmware version 1.20 or later. Only use the CTS delay field if you are using a Series 4000 receiver. Table 7.5 shows which receiver port the radio must be connected to when the CTS enabled field is set to Yes. Table 7.5
Receiver port – CTS enabled
Receiver
Receiver port
GPS Total Station 4800
Port 1 Note: Connect the TSC1 to Port 2
GPS Total Station 4700
Port 1 or Port 3 Note: Connect the TSC1 to Port 2
Series 4000
Port 2 or Port 4
Trimble Survey Controller Reference Manual Volume 1
131
Page 162
7 7.5.3
Survey Styles
Topo Point Select the Topo point menu item to set the parameters associated with observing topographic points. The Auto point step size field defines the increment size for automatic point numbering. The default is 1, but you can use larger step sizes as well as negative steps. It is possible to store quality control information with each point measurement. The default is QC1. For real-time surveys other options are QC1 & QC2 and QC1 & QC3. For more information, see Quality Control Records, page 379. Note – If you intend to use topo point data with TRIMNET™ software, record QC1 & QC2 records for each point. The Trimble Survey Controller software can terminate a topo point measurement and store the result automatically if the Auto end point field is set to Yes. When the number of measurements, the occupation time, and the horizontal and vertical precisions are satisfied, the point is measured and the result stored.
7.5.4
Observed Control Point Select the Observed control point menu item for another way to observe points in the field. This option lets you set different observational criteria from those used for topo point measurements. The Trimble Survey Controller software can terminate observed control point measurement and store the results automatically if the Auto end point field is set to Yes and the occupation times are satisfied. For RTK surveys, the number of measurements and the horizontal and vertical precisions must also be satisfied. The default setting for the Number of measurements field is 180. The extended occupation time suggests that this measurement type is ideally suited to points that will be used for control purposes.
13 2
Trimble Survey Controller Reference Manual Volume 1
Page 163
Survey Styles
7
Quality control information is automatically stored with each point: •
Real-time observed control points can store QC1, QC1 & QC2, or QC1 & QC3 records.
•
Postprocessed observed control points only store QC1 records.
For more information, see Quality Control Records, page 379. If the Topo point option is configured to perform 180 measurements, the positional result is similar to a point measured using the observed control point measurement type. Differences are:
7.5.5
• the default value in the Quality control field
• the observation class given by the office software when the point is downloaded
FastStatic Point You can measure a FastStatic™ point in a FastStatic survey. The Trimble Survey Controller software terminates a FastStatic occupation automatically if the Auto end point field is set to Yes and the specified occupation time is satisfied. The default occupation times are satisfactory for most users. If you change an occupation time, choose a setting according to the number of satellites being tracked by that receiver. Remember that both receivers must track the same satellite at the same time for the data to be useful.
B
Tip – Use a mobile phone or a walkie-talkie radio to verify that both receivers are tracking the same satellites.
Changing the occupation times directly affects the outcome of a FastStatic survey. Any changes should increase this time rather than decrease it.
Trimble Survey Controller Reference Manual Volume 1
133
Page 164
7 7.5.6
Survey Styles
Rapid Point Select the Rapid point menu item to configure a Rapid point™ observation. This is useful for in-field calculations where precision is not vitally important. Use the Rapid point observation method to quickly measure the position of the center line on a busy road, for example. Rapid points are automatically saved if the horizontal and vertical precisions are satisfied. The Trimble Survey Controller software collects just one epoch of data when the preset precisions are reached, so the default precision values should ideally be higher than for other point measurement types. The Trimble Survey Controller software uses this single epoch of data to define the point, making Rapid point the least precise measurement method. You can store quality control information with each Rapid point. The options are QC 1, QC1 & QC2, or QC1 & QC3. For more information, see Quality Control Records, page 379.
7.5.7
Continuous Points Continuous points use one epoch of data or one real-time measurement to create a point. In a real-time survey, the Trimble Survey Controller software automatically saves continuous points if the horizontal and vertical precisions are satisfied. In a postprocessed survey, it stores continuous points at the time interval specified in the Survey Style. Set this interval in the Logging interval field of the Rover options screen.
13 4
Trimble Survey Controller Reference Manual Volume 1
Page 165
Survey Styles 7.5.8
7
Stakeout To set the as-staked point details: 1.
Set the View deltas before storage field to Yes to view the differences between the design point and the measured as-staked point before storing the result. If you set this field to Yes, enter a value in the Horizontal tolerance field. The Trimble Survey Controller software displays the deltas if the tolerance is exceeded. The default is 0.000. With the default setting, the deltas are always displayed. Note – The Stake delta values are reported as differences from the measured/as-staked point to the design point.
2.
Set the name of the as-staked point to be the next auto point name or a point name that is equivalent to its design name.
3.
Set the code of the as-staked point to be the design point name or the design point code.
To set the display: 1.
2.
Set the Display mode field. The options are: –
Surveyor centered – the cross that represents your current position stays in the center of the screen and the target moves as you change position.
–
Target centered – the target stays in the center of the screen and the cross moves as you change position.
You can enter a value in the Zoom factor field. This is the amount that the display zooms in when you switch from Coarse mode to Fine mode while navigating to a point. The default value is 4.0. When you zoom in by this amount, the width of the graphical display corresponds to approximately one meter (or three feet).
Trimble Survey Controller Reference Manual Volume 1
135
Page 166
7
Survey Styles
3.
Set the Display grid deltas field. The options are: –
Yes – the change in Northing and Easting is displayed during stakeout.
–
No – a bearing and distance is displayed. See Figure 17.8 on page 406.
Note – When you stake out a point, the elevation of the current position is also displayed. 4.
If required, define a DTM and set the Display cut/fill to DTM field to Yes. The cut or fill relative to the DTM can be displayed. To use the DTM, select the name of the appropriate file in the DTM field. Note – You can create a DTM file from an ASCII file. Use the Trimble Geomatics Office or Trimble Survey Office software to do this. Full documentation is provided with that software.
5.
If required, choose a setting for the External display (NMEA) output) field. Do this if you need to: – navigate using an external display (such as Trimble’s NavTracXL™ or NT200 display) and a Series 4000 receiver
– output NMEA strings from a Site Surveyor 4400, 7400MSi™, GPS Total Station 4800, or GPS Total Station 4700 receiver when staking out a point or navigating to a point. To set the receiver to output NMEA strings, set the Enabled field to Yes. Set the other fields according to the equipment. Note – The External display (NMEA output) field is only available if the NMEA option is installed in the receiver. To check this see Options, page 354.
13 6
Trimble Survey Controller Reference Manual Volume 1
Page 167
Survey Styles
7
Table 7.6 summarizes the types of NMEA string that are output when the external display option is enabled. Table 7.6
NMEA output strings
Receiver
NMEA output strings
Series 4000
BWC, GGA, GLL, GSA, VTG, WPL, XTE, ZDA, GGK
Site Surveyor 4400
GGK at 1 Hz
7400MSi
GGK at 1 Hz
GPS Total Station 4800
GGK at 1 Hz
GPS Total Station 4700
GGK at 1 Hz
Note – With a GPS Total Station 4800 or 4700 receiver, the NMEA strings are output on Port 2 only. For more information about NMEA strings, refer to the receiver manual. You cannot start a survey if the External display (NMEA output) Enabled field is set to Yes, but the receiver does not support NMEA output. When you end a survey that outputs NMEA strings, the same NMEA strings are disabled in the receiver.
7.5.9
Site Calibration To set the parameters for computing a calibration, select the Site calibration menu item and do the following: 1.
The Fix H. scale field to 1.0: field details whether the calibration computation should compute a horizontal scale factor or not: –
To compute the horizontal scale factor, select No.
–
To fix the horizontal scale factor to 1.0, select Yes.
Trimble Survey Controller Reference Manual Volume 1