Page 51

PLACER.BK : Placer 3 Page 7 Monday, February 24, 1997 9:30 AM

Configuring the Placer GPS

Destination Address. This option is mandatory when configuring the Placer

GPS for autonomous reporting. The destination address (DA) message specifies the recipient of the time and distance reports. If you do not configure the Placer GPS for the destination address, time and distance reports will not be sent. Default value =

For CDPD : 0.0.0.0. an invalid IP address

Default value =

For MAP27 it is unspecified and invalid; first valid query message sets the DA to source address of query. This address will be used for time and distance reporting until, the destination address is explicitly set through the use of the DA message.

Scheduled Reporting Intervals. The Placer GPS can be configured to automatically issue reports when a specified distance has been traveled or a specified time period has elapsed using the ‘D’ qualifier. When configuring this setting, you must also specify the destination address (DA) to whom the reports should be sent (see above). Default value = No TDR (Time and Distance Reporting), quiet. Protocol Configuration. The ‘out of the box’ Placer is programmed for a specific communications protocol. While this is optional, you can use the protocol configuration (PC) message to further specify the communication protocol options. For example, if the Placer is configured for the MAP27 protocol, you can select protocol option 1 (SST) if you know that all your messages will be shorter than 23 characters. Default value = For CDPD: 0 = normal mode. Default value = For Map27: All MAP27 message services enabled. Signal Status Message. Optionally, you may specify the type of message to be reported upon a change in digital input status. There are two message options: a short message that contains position and status data, or an extended message that contains the same data as an LN message.

Default value = SS;MSG = XT, i.e. XT TAIP message is transmitted.

3-7

Page 52

PLACER.BK : Placer 3 Page 8 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

Table 3-1. Placer GPS Configuration Options and Default Values

Item #

Parameter

MAP27

CDPD

Use TAIP Message

1

Vehicle ID

Optional[unspec’d]

Optional[unspec’d]

ID

2

Reporting Mode n/a [ID,CS,EC,Cr=False] n/a [ID,CS,EC,Cr=False]

RP

3

Destination Address

Optional (no TDR) Mandatory (with TDR) [invalid]

Optional (no TDR) Mandatory (with TDR) [invalid]

DA, DXX

4

Signal Status

Optional [SS;MSG=XT]

Optional [SS;MSG=XT]

SS

5

Protocol Configuration

Optional [all MAP27 msg services enabled]

Optional [0=normal]

PC

6

Time and Distance Reporting

Optional [quiet]

Optional [quiet]

DXX

NOTE: The default settings specified in Table 3-1 are enclosed in square brackets [...].

3-8

Page 53

PLACER.BK : Placer 3 Page 9 Monday, February 24, 1997 9:30 AM

Configuring the Placer GPS

Configuring the Placer GPS 455DR When configuring the Placer GPS455 for dead reckoning operation, the odometer and gyroscope must be configured using the provided DOS utility program PCLRINIT.EXE. Additional information regarding receiver setup is provided in Table 3-1 and Chapter 6. Odometer. Use the PCLRINIT.EXE utility program to calibrate the odometer. Gyroscope. Use the PCLRINIT.EXE utility program to calibrate the gyroscope.

3-9

Page 54

PLACER.BK : Placer 3 Page 10 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

The Microsoft Terminal Program You can use the Windows Terminal program to setup the Placer GPS 450, 455 and 455DR. The Windows Terminal program is located in the Accessories folder shown in Figure 3-1. 1.

Double click on the Terminal icon to start the Terminal program.

Figure 3-1. Microsoft Windows Accessories Folder

Before you can begin using the Terminal program to send messages to the Placer GPS, configure the communications settings for the COM port that you are connecting to the Placer, and set up the terminal preferences so that what you type is echoed on the screen. Note that in its default mode, Terminal does not echo the characters typed at the keyboard.

3-10

Page 55

PLACER.BK : Placer 3 Page 11 Monday, February 24, 1997 9:30 AM

Configuring the Placer GPS

Terminal Settings for Communications To configure the Terminal program to communicate with the Placer GPS 455 via the computers serial communications port, configure the Communications options. 2.

Double click on the Communications option listed under the Settings Communications menu to modify the settings as indicated in Figure 3-2.

Figure 3-2. Terminal Programs Settings Menu

3-11

Page 56

PLACER.BK : Placer 3 Page 12 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

Terminal program Settings Menu Configure the COM port to the following settings: baud rate = 9600, data bits = 8, stop bits = 1, parity = none, and flow control = none. 3.

Figure 3-3. Terminal Program Communications Settings

3-12

Click on the desired COM port settings.

Page 57

PLACER.BK : Placer 3 Page 13 Monday, February 24, 1997 9:30 AM

Configuring the Placer GPS

Terminal Settings for Terminal Preferences Use the options under the Settings/Terminal Preference menu to modify the terminal preferences so that what you type is echoed on the screen. This will also automatically advance the cursor to the next line when you press the Enter key. The terminal preferences are listed in Figure 3-5. Figure 3-4 Terminal Preferences Menu Items

Figure 3-5 Terminal Preferences

3-13

Page 58

PLACER.BK : Placer 3 Page 14 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

NOTES: Microsoft Terminal will not function properly unless it is zoomed to a full screen. Click on the up arrow in the upper right hand corner of the Terminal window to zoom to a full screen. For a complete list of the TAIP messages, see Appendix A.

3-14

Page 59

PLACER.BK : Placer 4 Page 1 Monday, February 24, 1997 9:30 AM

Chapter 4

Installing the Placer GPS 450

4

The Placer GPS 450 can be installed in a variety of mobile environments. Follow the installation instructions and guidelines provided in this chapter for optimal performance. NOTE: For instructions on installing the Placer GPS 455 and 455DR, see Chapter 6.

Figure 4-1 Interconnect Diagram

Ignition Switch GPS Antenna

+12V

Power

Radio

MDT

4-1

Page 60

PLACER.BK : Placer 4 Page 2 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

Inventory Upon receipt of the Placer GPS 450, verify that you have the following components. Figure 4-1 illustrates the interconnection of the Placer GPS 450 components. Table 4-1. Placer GPS 450 Inventory Component

Part Number

Placer GPS 450 receiver processing unit

30837-10 or 30837-20

Antennas: Magnetic Mount Antenna and cable

28367-00 or

Hard Mount Antenna and Cable

31192-00 or

Hard Mount Antenna Cable (used with HMA option) right angle TNC straight TNC

31193 or 30893

Optional Accessories:

4-2

Communications cable (optional)

19309-00

Digital I/O cable (optional)

30512

Power Cable

30514