Page 171

PLACER.BK : AppendixA Page 49 Monday, February 24, 1997 9:30 AM

TAIP Protocol

Digital Inputs, GPS Source

1 n/a

D: packed binary Digital Inputs Most Significant 4 bits, least significant bit of 4 = Input Line #0 (AL0), bit set if line high GPS Source Least Significant 4 bits, (0=2D GPS, 1=3D GPS, 2=2D DGPS, 3=3D DGPS, 6=DR, 8=Degraded DR, 9=Unknown, 15=No fix available)

SVNs used

4 n/a

EEEE: binary data SVNs bit pattern: LSbit for SV 1, MSbit for SV32, bit set if SVN used

Total

18

The XT message provides, in compressed form, essentially the same data as the TAIP LN message. XT Report msgs will be sent according to time & distance parameters as configured by standard TAIP T&D command (F or D qualifier for the XT msg) and in response to queries (>QXT<). The XT message report also contains the current state of General Purpose Input Alarm lines connected to the Placer, and an XT msg will be sent on change in state of any of these inputs (subject to “;MSG=” qualifier for SS message.)

A-49

Page 172

PLACER.BK : AppendixA Page 50 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

Example

The following example shows a binary XT message, 2 Hex characters per byte, and conversion of each message item. 3E 58 54 31 CA D3 57 5F C1 27 A7 00 50 31 08 CE 21 50 10 60 01 3C (hex) Latitude: 31 CA D3 57 (hex) (bits 1-25) = 0011 0001 1100 1010 1101 0011 0 = 0 63 95 A6 (hex) = 6460374/ 10**7 = 0.6460374 radians = 0.6460374 * 180 / Pi = 37.0152 degrees Longitude: 57 5F C1 27 (hex) (bits 2-27) = 101 0111 0101 1111 1100 0001 001 (sign bit set) 2’s complement = - 1010001010000000111110111 = - 21079703 /10**7 = -2.1079703 radians = - 2.1079703 * 180 / Pi = -120.77774. degrees Altitude: 27 A7 (hex) (lower 13 bits) = 0 0111 1010 0111 = 7A7 (hex) = 1959 (dec) 1959 - 2000 = - 41 m (rel. to MSL) Speed: Heading:

00 (hex) = 0 MPH 50 31 (hex) (1st 12 bits) = 503 (hex) = 1283 (dec) 1283 / 10 = 128.3 degrees

Time: 31 08 CE (hex) (lower 20 bits) = 1 08 CE (hex) 67790/ 10 = 6779 secs in day Digital Inputs: 21 (hex), (1st 4 bits) = 0010 (binary) Digital Input Line 0 = AL0 Digital Input Line 1 = AL1 GPS Source: 21 (hex), (lower 4 bits) = 0001 (binary) 1 = 3D GPS SVNs used: 50 10 60 01 (hex) = = 0101 0000 0001 0000 0110 0000 0000 0001 (binary) SVNs 1, 14, 15, 21, 29, 31 used

A-50

Page 173

PLACER.BK : AppendixA Page 51 Monday, February 24, 1997 9:30 AM

TAIP Protocol

X1

Extended Diagnostics Message 1; Dead Reckoning (Placer 455 only) The format of the data string is as follows: ,A,BC,DDDDDDD,EF,GG.GGGG,HH.HHHH,II.IIII Item

# of Char

Units

Format (Value)

Diagnostics sub-message ID

1 n/a

A

Odometer Status 1

1 n/a

B (reserved)

Odometer Status 2

1 n/a

C (see table below)

Odometer Scale Factor

7

Pulses/Mile

DDDDDDD

Gyro Status 1

1 n/a

E (reserved)

Gyro Status 2

1 n/a

F (see table below)

Gyro Rate Bias

7

Deg/Sec

GG.GGGG

Gyro Left Scale Factor

7 n/a

HH.HHHH

Gyro Right Scale Factor

7 n/a

II.IIII

Total

40 (Including commas and decimal points)

A-51

Page 174

PLACER.BK : AppendixA Page 52 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

Odometer Status

Value of C

No valid time for odometer measurements

Backup light drive)

Odometer scale factor is out of tolerance

No pulses received from odometer since start-up

0 1

A-52

X

2

X

3

X

4

X

5

X

6

X

X

7

X

X

X

X

8

X

9

X

A

X

B

X

C

X

X

D

X

X

E

X

X

X

F

X

X

X

X

X

X

X

X

Page 175

PLACER.BK : AppendixA Page 53 Monday, February 24, 1997 9:30 AM

TAIP Protocol

Gyro Status 1

Value of C

0

Gyroscope scale factor calibration has not been perfromeds

No valid for gyroscope measurements

Heading has not been initialized

Zero bias not perfrormed no problem reported

1

X

2

X

3

X

4

X

5

X

6

X

X

7

X

X

X

X

8

X

9

X

A

X

B

X

C

X

X

D

X

X

E

X

X

X

F

X

X

X

X

X

X

X

X

A-53

Page 176

PLACER.BK : AppendixA Page 54 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

Gyro Status 2

Value of C

0

Gyro scale factors out of tolerance

Gyro bias is out of tolerance

Gyro Hardware failed internal dignostics no problem reported

1

X

2

X

3

X

4

X

5

X

6

X

X

7

X

X

X

X

X

Example: An Odometer Status 2 value of “0” indicates no faults. An Odometer Status 2 value of “4” simply indicates the backup light is active. An Odometer Status 2 value of “2” indicates the odometer scale factor is out of tolerance. Example: A Gyro Status 2 value of “0” indicates no faults. A Gyro Status 2 value of “5” indicates the gyro hardware failed the internal diagnostics and that the scale factors are out of tolerance.GPSSK

0

A-54

Page 177

PLACER.BK : AppendixB Page 1 Monday, February 24, 1997 9:30 AM

Appendix B

Mechanical Drawings

0

This appendix contains mechanical drawings and specifications for the Placer GPS 450/455 equipment.

B-1

Page 178

PLACER.BK : AppendixB Page 2 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

B-2