Page 17

Step 4: Collect Data - A Temperature Experiment Now you are ready for the fun part - collecting data! Here is a simple temperature experiment to try.4 It will guide you through the process of making measurements using a temperature probe and the CBL system. Once you are familiar with the basic steps, you will be able to perform any experiment with the CBL. It’s that easy!

OBJECTIVES In this experiment, you will • use a TI graphing calculator, a CBL System, and a temperature probe to measure temperature • record data • make a graph of the data

MATERIALS CBL System TI graphing calculator TI Temperature Probe CHEMBIO, PHYSICS, or PHYSCI program

TI-GRAPH LINK two 250-ml beakers or two glasses cold water (cooled with ice) hot water

Figure 1 PROCEDURE 1. Place about 100 ml of tap water into a 250-ml beaker or a glass. Add two or three ice cubes. 2. Place a temperature probe into the cold water and stir briefly. Then position the probe in the coldwater beaker as shown in Figure 1. 3. Plug the temperature probe into Channel 1 of the CBL System. Connect the CBL System to the TI graphing calculator with the link cable using the port at the bottom of each unit. Firmly press in the cable ends.

4

This is a modified version of Experiment 1 in Physical Science with CBL, by Don Volz and Sandy Sapatka

CBL Made Easy!

13

Page 18

Step 4

Collect Data

4. Turn on the CBL unit and the calculator. Follow these steps to start the CHEMBIO, PHYSICS, or PHYSCI program on your calculator: TI-73, 82 or 83 Calculators: Press PRGM , then press the calculator key for the number that precedes CHEMBIO, PHYSICS, or PHYSCI program (usually 1 ). Press ENTER , then press ENTER again to go to the MAIN MENU. TI-83 Plus Calculators

Press APPS , then press the calculator key for the number that precedes CHEMBIO, PHYSICS, or PHYSCI program. Press ENTER , then press ENTER again to go to the MAIN MENU.

TI-85 or 86 Calculators: Press PRGM , press F1 to select < NAMES >, and press a menu key to select < CHEMB >, < PHYSIC >, or < PHYSCI > (usually F1 ). Press ENTER , then press ENTER again to go to the MAIN MENU. TI-89, 92 or 92 Plus Calculators: Press 2nd [VAR-LINK]. Use the cursor pad to scroll down to “chembio,” “physics,” or “physci” then press ENTER . Press ) to complete the open parenthesis that follows “chembio,” “physics,” or “physci” on the entry line and press ENTER . Press ENTER again to go to the MAIN MENU. 5. Set up the calculator and CBL for one temperature probe and a temperature calibration. • Select SET UP PROBES from the MAIN MENU. • Select “1” as the number of probes. • Select TEMPERATURE5 from the SELECT PROBE menu. • Enter “1” as the channel number (in the PHYSICS program, press ENTER ). • Select USE STORED from the CALIBRATION menu (this menu will appear only if you are using the

Vernier Direct-Connect Temperature Probe or Standard Temperature Probe). 6. Set up the calculator and CBL for data collection. • Select COLLECT DATA from the MAIN MENU. • Select TIME GRAPH from the DATA COLLECTION menu. • Enter “4” as the time between samples, in seconds. • Enter “25” as the number of samples (the CBL will collect data for a total of 100 seconds). • Press ENTER , then select USE TIME SETUP to continue. Note: If you want to change the sample time or sample number you entered, select MODIFY SETUP. Then choose, on the TI-85, “LIVE = LIVE DISPLAY.” • Enter “0” as the minimum temperature (Ymin). • Enter “80” as the maximum temperature (Ymax). • Enter “10” as the temperature increment (Yscl). Do not press ENTER to begin data collection until

Step 8. 7. Get about 150 ml of hot water in a second 250-ml beaker. Note: In Step 9, you will switch the temperature probe from the cold water to the hot water at exactly 20 seconds after you have begun data collection. This will be done as the fifth data point appears on the calculator screen (5 X 4 seconds = 20 seconds). 8. When everything is ready, press the water.

5

ENTER on the calculator to begin data collection. Do not stir or move

If you are using a Standard Temperature Probe (with a box in the cable), select 1:VERNR STD TEMP.

14

CBL Made Easy!

Page 19

Collect Data

Step 4

9. When exactly 20 seconds have gone by (when the fifth data point appears on the calculator screen), quickly move the temperature probe to the beaker containing hot water and continue data collection. Do not stir the water or move the temperature probe during the remainder of the data collection period. 10. When data collection is complete, press ENTER to display a graph of temperature vs. time on the to examine the data points along the curve. calculator screen. Use 11. View the calculator data lists and record your temperature data. Press ENTER , then select NO when asked if you want to repeat the trial. Select VIEW DATA from the MAIN MENU (In the PHYSICS program, select QUIT). TI-73, 82, 83, or 83 Plus Calculators: To view the data lists, press STAT , then select EDIT. You can use the arrow keys to scroll through the time data (L1) and the temperature data (L2). Record the temperature values in your Data Table (round to the nearest 0.1°C). TI-85 Calculators: Press STAT , then select < EDIT > by pressing F2 . Select < L1 > (time) as the xlist Name by ENTER . Select < L2 > (temperature) as the ylist Name by pressing F4 ENTER . pressing F3 The time values are now displayed on the calculator screen as x1–x50 and the temperature values to scroll through the data pairs. for Part II are stored as y1–y50. Press TI-86 Calculators: Press 2nd [STAT], then select < EDIT > by pressing the data lists L1 (time) and L2 (temperature).

F2

. Press to scroll down through

TI-89, 92, or 92 Plus Calculators: To view the data matrix, press APPS , select Data/Matrix Editor, then Current. Use the cursor pad to scroll down through the data lists c1 (time) and c2 (temperature).

DATA TABLE Time (s)

Temp (°C)

Time (s)

Temp (°C)

Time (s)

Temp (°C)

Time (s)

Temp (°C)

4

______

32

______

56

______

80

______

8

______

36

______

60

______

84

______

12

______

40

______

64

______

88

______

16

______

44

______

68

______

92

______

20

______

48

______

72

______

96

______

24

______

52

______

76

______

100

______

28

______

Now that you have collected data, would you like to print a graph? If so, go on to Step 5.

CBL Made Easy!

15

Page 20

This Page Intentionally Left Blank

Page 21

Step 5: Sending Graphs and Data to Your Computer (optional) Now that you have collected data, you can, of course, analyze data with your calculator. However, if you wish to analyze the data on a computer or print the data, you will need to use the TI-GRAPH LINK cable to transfer the data back to your computer. Graphical Analysis and Logger Pro 3 programs are not required for data collection with the CBL. However, most people have found them great tools for directly moving CBL data from the graphing calculator to the computer for graphing and printing. It is also very good for performing mathematical modeling and finding the relationships between variables. Importing procedures for TI-73, TI-73 Explorer, TI-83, TI-83 Plus, TI-83 Plus Silver Edition, TI86, TI-89, TI-92, TI-92 Plus, Voyage 200: 1. Connect the TI-GRAPH LINK cable to a free serial or USB port of the computer and to the TI calculator (see below if you are using the TI-82 or TI-85 models). 2. Turn on the calculator. 3. With Graphical Analysis/Logger Pro running, pull down the File menu and choose Import From → TI Calculator or LabPro/CBL... or button from the toolbar. The dialog box to the right click the should appear. 4. From the pull-down menu, choose USB port or serial port (COM 14 on a PC, modem or printer on a Macintosh) to which the TI-GRAPH LINK cable is connected. 5. If you are using a PC serial cable, identify whether it is a gray or black cable. 6. Click on the Scan for Calculator button. The calculator model you are using should now be identified, and you should see a message, "Ready to Import." 7. Click on the data list(s) that you want to import. (To select more than one list on a Macintosh, hold key while you click). down the 8. Click OK to send the data lists to the computer. The data will appear in columns in the data table. They will be labeled with the simple list names from the calculator. If you want to re-name them or add units, double-click on the column heading in the data table and enter new labels and units. Importing procedures for the TI-82 and TI-85: 1. Pull down the File menu and choose Import From -> TI Calculator or LabPro/CBL... or click the button from the toolbar. 2. Scan for calculator (if needed). 3. Note message "Waiting for you to transmit data from your calculator...". 4. You can then choose which lists to transmit to the computer. Here's how:

CBL Made Easy!

17

Page 22

Step 5

Sending Graphs and Data to the Computer TI-82: On the TI calculator, press

2nd

[LINK], then select 2:SelectAll-... from the SEND menu.

Use to locate the lists on the SELECT menu. Position the arrow in front of a list you want to send to Logger Pro and press ENTER to select it. More than one list may be selected in this manner. A black square will appear beside each list that will be sent. To deselect, press ENTER . The black square will disappear. Press , then select 1:Transmit. The lists will appear in the import window. They will be labeled with simple list names from the calculator. TI-85: On the TI calculator, press

2nd

[LINK], then choose < SEND >. Press MORE , then choose < LIST >.

Use to locate a list you want to send and choose < SELCT > to select it. More than one list may be selected in this manner. A black square will appear beside each list that will be sent. To deselect, choose < SELCT >. The black square will disappear. Choose < XMIT > to transmit the list(s) to the computer. The lists will appear in the import window. They will be labeled with simple list names from the calculator. 5. Click on the data list(s) that you want to import. (To select more than one list on a Macintosh, hold key while you click). down the 6. Click Done to send the data lists to the computer. The data will appear in columns in the data table. They will be labeled with the simple list names from the calculator. If you want to re-name them or add units, double-click on the column heading in the data table and enter new labels and units.