Spec sheet · Telsey
Telsey DMA 122/123 Enhanced Digital Modulation Analyzer Spec Sheet
Spec sheet3 pagesPDF 505 KB
All 3 pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Telsey spec sheet for the DMA 122/123 Enhanced Digital Modulation Analyzers, handheld field meters for checking the quality of digital QAM cable TV signals. It covers the DMA 122 for North American ITU-T J.83 Annex B systems and the DMA 123 for European DVB-C, and lists their digital, RF and analog measurement specifications.
- What it is
- Field portable analyzer for measuring the quality of digital cable TV (QAM) signals, analog and digital, downstream and upstream p. 1
- Standards
- DMA 122: ITU-T J.83 Annex B (North America), 64-256 QAM; DMA 123: DVB-C, ETS 300 429, 64-256 QAM p. 2
- Measurements
- Signal level, adjacent channel levels, MER, estimated noise margin, EVM, BER before and estimated BER after FEC p. 1
- Power
- Rechargeable NiMh battery p. 1
- Controls
- Menu driven display with softkeys; an analysis in 2 keystrokes p. 1
- Housing
- Rugged, weather resistant handheld package with a protective soft case p. 1
- Lock indicators
- Demodulator status shows symbol lock, FEC lock and MPEG lock p. 2
- Analog level meter
- Video and audio carrier: 20 to 120 dBuV (typ); +/- 1.5 dB (typ) at 18 to 25°C, +/- 3 dB (typ) at 0 to 40°C p. 3
- Level units
- dBuV, dBmV, dBm, dBpW p. 3
- Digital C/N
- Channel power to noise, 3 to 40 dB p. 3
- Analog C/N
- Video and audio carrier to noise, in service and out of service p. 3
- Other tests
- All channels sweep, adjacent channels level, signal level difference p. 3
- Head-end use
- Extended dynamic range for IF measurements at the head-end p. 1
- Maker
- Telsey S.p.A., Quinto, Italy p. 1
What this sheet walks you through
- Digital measurement specifications of the DMA 122 and DMA 123 p. 2
- RF digital and analog signal level meter specifications p. 3
Good to know
- BER after forward error correction is an estimate. p. 1
- The analog level meter accuracy figures are typical values. p. 3
Questions this sheet answers
Which cable TV standard does the Telsey DMA 122 support?
ITU-T J.83 Annex B, the North American standard, with 64 to 256 QAM. The DMA 123 is the DVB-C version. p. 2
What battery does the Telsey DMA analyzer use?
A rechargeable NiMh battery. p. 1
What does the DMA 122 measure on a digital channel?
Signal level, adjacent channel levels, MER, estimated noise margin, EVM, and BER before and estimated BER after FEC, without taking channels out of service. p. 1
In what units does the DMA analyzer show signal level?
dBuV, dBmV, dBm or dBpW. p. 3
The file
Size and text
Every page · 3
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 3
Open in the PDF
The text of page 1, from the PDF itself
DMA Enhanced
Digital Services Analyzer
Key Feature
- Full 256-64 QAM testing
- RF analog measurements
- 5-860 MHz input band
- Extended dynamic range
- IF Measurements
- Fast all channels sweep
- Modularity for multiple applications
- Modularity for easy/cost effective
upgrade
- Easy menu driven navigation
- Portable light-weight rugged design
- Protective soft-case
- Rechargeable NiMh battery
The DMA 122/123 Enhanced Digital Modulation Analyzers is a field portable measurement instrument designed for cable TV operators interested in measuring the quality of digital Cable TV signal streams. The instrument consists of a rugged handheld package with all the measurements required to analyze and verify the quality of QAM modulated signals. The DMA Series supports signals formats compliant with the ITU-T j.83 standard adopted in the USA as well as the European DVB-C standard. The new DMA advanced is capable of analog and digital measurement in both downstream and upstream band. It as also an extended dynamic range to make possible IF measurements at Head-end.
Telsey S.p.A. Via dell’Industria,1 Quinto 31055 Italy Tel: +39 0422 470840 Fax: +39 0422 470920 www.telsey.it E-mail : sales@telsey.it
Cable TV and Telecommunications Network operators will benefit from the instrument’s ability to provide key in-service measurements required for understanding and verifying the quality of Digital Television signals. Automated measurements include signal level, adjacent channel levels, modulation error ratio (MER), estimated noise margin, error vector magnitude (EVM), and BER before – and estimated BER after - forward error correction (FEC). These measurements allow operators to determine acceptable transmission quality quickly and easily, without removing channels from service. The DMA Series utilizes a simple menu driven display with a «softkey» interface providing an in-depth analysis of system impairments with only 2 keystrokes. Designed for the rugged outside plant environment, the instrument is housed in a weather resistant package and is powered by a rechargeable NiMh battery.
Page2of 3
Open in the PDF
The text of page 2, from the PDF itself
DMA Enhanced
Digital Services Analyzer Features Applicable standards Impedance Dimensions Weight Input Connector PC Interface Power Supply Battery Type Battery R u n T i m e Battery Charge Time Operating Temperature Storage Temperature Printer Support
E T S I E T S 3 0 0 -8 0 0 , E T S 3 0 0 -4 2 9 , I T U- T J . 8 3 A n n e x A , B 75 Ohm 318 x 170 x 60 (mm); 12.5 x 16.7 x 2.3 (In); 2.1 Kg Field replaceable “F” female ( BNC optional) RS232 t h r o u g h a n R J 4 5 c o n n e c t o r ( a d a p t e r i n c l u d e d ) 230Vac 50Hz (Europe) 110Vac 60Hz (USA) NiMh 2.5h (typical) 4h (typical) -5 t o 4 5 ° C , 2 3 t o 1 1 3 F -15 to 5 5 ° C , 5 t o 1 3 1 F S e i k o D P U-414
Specifications Applicable Standard Modulation supported Symbol Rate Frequency Channel Bandwidth
DMA 123 D V B- C ETS 300 429 64-2 5 6 Q A M 5 - 6.956 Mbaud 5 - 866 MHz 8 MHz
DMA 122 North America ITU- T J . 8 3 A n n e x B 64-2 5 6 Q A M 5.057 - 5.360 Mbaud 5 - 860 MHz 6 MHz
Digital Measurements Demodulator Status Symbol Lock FEC Lock MPEG Lock Modulation Error Ratio Range Error Vector Magnitude Range Estimated Noise Margin
BER before & after FEC
Yes Yes Yes(*) Yes Yes(*) Yes (*) FEC & MPEG lock together 22-3 5 d B ( 6 4 Q A M ) 30-3 5 d B ( 2 5 6 Q A M )
22-3 8 d B ( 6 4 Q A M ) 28-3 8 d B ( 2 5 6 Q A M )
1 . 2 % -5.2%(64QAM) 1 . 1 % -1.9%(256QAM)
0 . 8 % -5.2%(64QAM) 0 . 8 % -2.4%(256QAM)
1-1 0 d B ( 6 4 Q A M ) 3-5 d B ( 2 5 6 Q A M )
1-1 5 d B ( 6 4 Q A M ) 2-10dB(256QAM)
10 -4 -10 -9 ( 6 4 Q A M) 10 -4 -10 -6 (256QAM)
10 -4 -10 -9 (64QAM) 10 -4 -10 -8 (256QAM)
Spectrum Analyzer Frequency Range 5-870 MHz L e v e l ( @ 8 M H z C h B w , 1 3 5 K H z R B W ) 40-1 2 0 d B u V ( t y p ) Constellation resolution Equalizer D y n a m i c R a nge
5-863 MHz 40-1 2 0 d B u V ( t y p )
8 bits(I,Q)8 bits(I,Q)-4 0 t o 1 0 d B c-4 0 t o 1 0 d B c
Page3of 3
Open in the PDF
The text of page 3, from the PDF itself
DMA Enhanced
Digital Services Analyzer RF Measurements RF Digital Signal Level Meter Channel Bandwidth Range Accuracy @18 to 25°C @ 0 to 40°C Adjacent channel maximum difference Measurement Units
6 - 8 MHz 40 to 120 dBuV (typ) +/- 1.5 dB (<+/ - 1 d B ) ( 6 4 Q A M ) +/- 1.8 dB (<+/ - 1dB) (256QAM) +/- 3 d B 15 dB ( 8MHz BW) 10 dB ( 6MHz BW) dBuV, dBmV, dBm, dBpW
RF Analog Signal Level Meter (Video Carrier) Range 2 0 t o 1 2 0 d B u V (typ) Accuracy 18 to 25°C +/- 1 . 5 d B ( t y p ) 0 to 40°C +/- 3 d B ( t y p ) A d j a c e n t c h a n n e l m a x i m u m d i f f e r e n c e 1 0 d B ( a n a l o g o r d i g i t a l) Measurement Units dBuV, dBmV, dBm, dBpW RF Analog Signal Level Meter (Audio Carrier) Range 20 to 120 dBuV (typ) Accuracy 18 t o 25°C +/- 1 . 5 d B ( t y p ) 0 to 40°C +/- 3 d B ( t y p ) Adjacent channel maxi mum difference 10dB (analog or digital) Measurement Units dBuV, dBmV, dBm, dBpW RF Analog Signal Level Meter (Video Carrier - Audio Carrier Difference) Range V i d e o a n d a u d i o c a r r i e r s s imultaneously inside their specification Accuracy 18 to 25°C +/- 2 d B ( t y p ) 0 to 40°C +/- 3 d B ( t y p ) A d j a c e n t c h a n n e l m a x i m u m d i f f e r e n c e 10dB Measurement Units dBuV, dBmV, dBm, dBpW Digital Channel Power to Noise (C/N) (Modulated Signal to Noise) Range 3 to 40 dB Accuracy 18 to 25°C +/- 2 d B ( < + /- 1 d B ) Other analog and mixed analog/digital channels measurements Analog Video Carrier Power to Noise (V.C/N) In Service Analog Audio Carrier Power to Noise (A.C/N) In Service Analog Video Carrier Power to Nois e (V.C/N) Out of Service Analog Audio Carrier Power to Noise (V.C/N) Out of Service All Channels Sweep Adjacent Channels Level Signal Level Difference Accuracy (18 to 25°C) Accu r a c y ( 1 8 t o 2 5 ° C )
-2 5 t h r u + 1 0 d B ( A d j a c e n t t o R e f e r e n c e ) +/- 2 d B ( w h e n o n l y d i g i t a l c h a n n e l s ) +/- 2 d B t y p ( w h e n m i x e d a n a l o g / d i g i t a l c h a n n e l s )