Appendix A Troubleshooting, Technical Support & Equipment Returns
Introduction This chapter provides a checklist of common problems and their potential solutions.
Initial Checklist Perform an initial check of the VRC unit as follows: 1. Check the unit for any signs of exterior damage. 2. Check and reseat all rear panel cable connections. 3. Check to be sure the VRC is receiving operating power. a. VRC 4000 - Check the circuit breakers feeding the 110VAC wall outlet supplying power to the VRC. Make sure the wall-mounted power supply is firmly seated in the wall outlet. If a surge protector is installed between the wall-mounted power supply and the wall outlet, make sure that if it has an ON/OFF switch, that it is on, and that any fuses or circuit breakers on the surge protector have not blown or tripped. b. VRC 4040 - Be sure the vehicle’s battery is not dead. Verify that the ON/ OFF switch on the DC power converter is on. Reseat the connectors on both the power input and output cables on the DC power converter.
Specific Problems The following pages present solutions to specific problems or malfunctions.
Touchscreen Does Not Respond The video display appears to be working properly; however, touching the screen does not cause anything to happen.
A-1
Page 52
VRC 4000 Product Reference Guide
Possible Causes and Solutions The touchscreen drivers did not load, the touchscreen may be disconnected or defective. Reboot the VRC. If this does not solve the problem, contact the factory for assistance. In DOS applications, in the CONFIG.SYS file, verify the command line reads: TBDRIVER /A: 2AO /I:91
Application Program Does Not Appear An image is displayed on the display, such as the self-test message, but the application is not displayed.
Possible Causes and Solutions The application software is corrupted, or the config.sys and autoexec.bat files are not set up properly. Reload the application software on the system, verify the config.sys and autoexec.bat files are set up correctly to load the application program and reboot the system.
PCMCIA Card(s) Not Working The peripheral on the PCMCIA card does not function, or the system does not display the card as drive D:\ or E:\ (memory cards).
Possible Causes and Solutions Verify the config.sys and autoexec.bat files are set up correctly to recognized PCMCIA cards, try the card in the other PCMCIA slot, or check to make sure the card is firmly seated in the slot.
Modem Card Does Not Work With a PCMCIA modem card installed in one of the slots, the VRC does not receive a dial tone.
Possible Causes and Solutions Check to be sure the modem card is firmly seated in the PCMCIA slot. Check the modem setup strings in the software package used with the modem card. Check the telephone line connections. A-2
Page 53
Appendix A: Troubleshooting, Technical Support, and Equipment Returns
VRC 4000 Does Not Communicate with the Network The VRC 4000 is operating but does not communicate with the network through its hard-wired connection.
Possible Causes and Solutions Check for cable breaks, shorts and bad crimps using a cable scanner. Check for electrical interference. Check the security ID and domain station type.
VRC 4040 Does Not Communicate with the Network The VRC 4040 is operating but does not communicate with the network through its wireless connection.
Possible Causes and Solutions Check that the antenna connection is secure. Replace broken antennas or cables. Check the security ID and domain station type. Ethernet Connection: Remove any other installed NICs in the ISA expansion slot or PCMCIA slots. Check that the network configuration is set for I/O 240, interrupt 15 and DMA 3. Check that the Ethernet is enabled.
A-3
Page 54
VRC 4000 Product Reference Guide
Service Information If you have a problem with your equipment, contact the Symbol Support Center. Before calling, have the model number and serial number. Call the Support Center from a phone near the equipment so that the service person can try to talk you through your problem. If your problem cannot be solved over the phone, you may need to return your equipment for servicing. If that is necessary, you will be given specific directions. Note:
Symbol Technologies is not responsible for any damages incurred during shipment if the approved shipping container is not used. Shipping the units improperly can possibly void the warranty. If the original shipping container was not kept, contact Symbol to have another sent to you.
Symbol Support Center For service information, warranty information or technical assistance, call:
USA SYMBOL SUPPORT CENTER 1-800-653-5350
Canada Mississauga, Ontario Canadian Headquarters (905) 629-7226
Europe Wokingham, England European Headquarters 0734-771-222 (Inside UK) +44-1734-771222 (Outside UK)
A-4
Page 55
Appendix A: Troubleshooting, Technical Support, and Equipment Returns
Asia Singapore Symbol Technologies Asia, Inc. 337-6588 (Inside Singapore) +65-337-6588 (Outside Singapore) If you purchased your Symbol product from a Symbol Business Partner, contact that Business Partner for service.
A-5
Page 56
VRC 4000 Product Reference Guide
A-6
Page 57
Appendix B System Reference CPU The VRC main circuit board assembly contains the central processing unit (CPU), DRAM, and an optional Flash-ROM configured as a DOS device. The VRC is configured with an AMD 5x86 processor. This CPU is driven by a 33MHz clock signal from the main timer circuits. It runs internally at 133MHz.
System Cache The VRC is configured with a 16KB Level 1 processor cache memory. Optional configurations include 128KB or 256 KB Level 2 processor cache memory.
VRC BIOS The VRC System BIOS is an industry-standard basic input/output system configured to support all onboard input/output (I/O) functions. It incorporates an advanced system set-up utility, as well as an extensive series of internal diagnostics for system test and verification. The standard BIOS is contained in a single 128Kbyte Flash device and uses non-volatile CMOS RAM to store the real-time clock, system configuration, and system diagnostic information. The Flash device supports in-circuit reprogramming for BIOS updates, adding features, or reconfiguring certain system parameters. The BIOS has been initialized to facilitate all communications between the operating system, CPU and peripheral devices. The VRC BIOS includes the main System BIOS, the Video BIOS, and the system Set-Up Utility. Additional device drivers can also be added. The System BIOS consists of a routine designed to test the system hardware, bootstrap load the operating system and bootstrap load the device drivers. The 64Kbyte System BIOS module resides in memory address spaces 0C,0000H to 0C,FFFFH. B-1
Page 58
VRC 4000 Product Reference Guide
The 32Kbyte Video BIOS module resides in memory address spaces 0E,0000H to 0E,7FFFH. The Set-Up Utility is used to configure the system parameters.
System Memory Configuration The VRC system memory can be configured with up to 64 MB of dynamic random access memory (DRAM). The DRAM is implemented in two 3.3 volt SODIMMs (small outline dual in-line memory modules) that plug in to sockets on the motherboard. Each SODIMM socket can hold either a SODIMM containing 4, 8, or 16 MB. All system memory above 1 MB is accessible as extended memory. Table B-1 illustrates some possible DRAM combinations installed in the two SIMM sockets. Table B-1. System Memory SIMM Combinations Total RAM
Socket 1
Socket 2
4MB
4
0
8MB
4
4
8MB
8
0
16MB
8
8
16MB
16
0
CMOS RAM On-board feature configuration information is stored in AT-style CMOS random access memory (RAM). The VRC integrates 128 bytes of CMOS RAM and real time clock (RTC) into the main system controller. The system’s CMOS RAM is accessed via I/O locations 0070H - 0071H. Table B-2 shows the configuration of the system’s available memory.
B-2