Page 17

Chapter 2 Installation and Maintenance Physical Installation VRC 4000 The VRC 4000 can be fixed-mounted almost anywhere that is convenient to the operator. The mounting location must be near a standard 110VAC electrical outlet, and there must be sufficient space below the unit for cable access to the rear panel, which faces downward when the unit is wall-mounted. The optional mounting bracket should be secured to the wall prior to attaching the VRC 4000 to the bracket. All cable connections should be made to the VRC 4000 before the system is powered up. Since there is no ON/OFF switch, the unit powers up as soon as the power supply connections are completed and the power supply is plugged in to the 110VAC outlet. Power line transients, spikes and sags induced by other equipment in the operating environment can stress the VRC’s power supply, and can reduce the voltage at the VRC below its nominal +12VDC operating voltage. To avoid the possibility of large inrush currents which will open the power supply’s internal fuses (necessitating the premature replacement of the power supply) the use of a single-outlet surge suppressor/spike protector is highly recommended.

2-1

Page 18

VRC 4000 Product Reference Guide

VRC 4040 The VRC 4040 mounts to a forklift or other vehicle with a universal mounting bracket. Operating power is obtained from a DC power converter that attaches to the vehicle’s electrical system via an access cord. Installation of the VRC 4040 requires mounting the bracket, installing the DC power converter, and attaching the access cord to the vehicle’s electrical system. Since vehicle electrical systems vary, the wiring instructions given here are intended as a guide only. If you require specific instructions for a particular make and model forklift, hostler, or motorized pallet, please contact Symbol Technologies’ technical support at 1-800 653-5350. The mounting bracket should be located so that the VRC 4000 touchscreen is clearly visible, easily accessible and easily operated. Also, make sure that the intended mounting location provides adequate access for cables to the rear panel (bottom) of the VRC 4000. To provide maximum safety for both the vehicle operator and the equipment, the VRC 4000 and its DC power converter should both be mounted completely within the vehicle’s outer dimensions and profile. If required, mark and drill the mounting holes, using the mounting bracket as a template. Mount the bracket, and if used, the remote antenna. Mount the VRC to the bracket using the knobs and washers prior to making any final cable connections. Note: When installing the computer on an electrical vehicle, electrical isolation between the vehicle chassis ground and the exterior case of the computer should be maintained. The standard mounting bracket provides the necessary isolation provided that the computer is positioned such that it does not make direct contact with the vehicle chassis.

DC Power Converter Installation The DC power converter mounts to a steel surface on the vehicle via its magnetic feet. It should be located so as not to interfere with either moving parts on the vehicle or the operator’s vision. Be certain that the VRC 4040 DC power cable from the converter can reach the mating connector on the VRC 4040. 2-2

Page 19

Chapter 2: Installation and Maintenance

Electrical Harness Access Cable The access cable should be connected to the vehicle’s electrical system, at a point that provides power at all times, and that is filtered and fused. Never connect the access cable directly to the battery terminals/ Possible connection points are at the horn, lights (feed) or ignition switch (feed). 24-48V Power Converter The electrical harness access cable for the 24-48V Power Converter has two leads at one end which are permanently wired into the vehicle’s electrical system. The other end of the cable has a circular 2-pin connector with rubber boot that mates with a similar connector on the DC power converter’s power input cable. The BLACK harness wire is connected to a POSITIVE voltage source. The WHITE harness wire is connected to the NEGATIVE voltage source. The booted connector end of the cable should be accessible for convenient attachment to the DC power converter. Make sure the DC power converter ON/OFF switch is in the OFF position. Once the access cable is wired to the electrical system, mate the connectors on the access cable and the DC power converter power input cable. All cable connections must be completed before applying power to the VRC 4040. 12V Power Converter The electrical harness access cable for the 12V Power Converter has three leads at one end which are permanently wired into the vehicle’s electrical system. The leads are WHITE and BLACK, plus a third lead that is either shield braid or GREEN. The other end of the cable has a circular 3-pin connector with rubber boot that mates with a similar connector on the DC power converter’s power input cable. The BLACK harness wire is connected to a POSITIVE voltage source. The WHITE harness wire is connected to the NEGATIVE voltage source. The GREEN or braided lead is connected to chassis ground. The booted connector end of the cable should be accessible for convenient attachment to the DC power converter.

2-3

Page 20

VRC 4000 Product Reference Guide

Make sure the DC power converter ON/OFF switch is in the OFF position. Once the access cable is wired to the electrical system, mate the connectors on the access cable and the DC power converter power input cable. All cable connections must be completed before applying power to the VRC 4040.

Network Connections The VRC is factory-equipped with a network interface card (NIC) and the appropriate network software for communicating with the network. The physical network connection requirements for hard-wired and wireless operation are provided below. The network port on the VRC uses different connectors, depending on the type of network for which the VRC is factoryconfigured. For Token Ring connections, a DB9 connector is used. For Ethernet connections, an RJ-45 connector is used. For wireless network communications, a non-standard RF antenna connector (reverse BNC, reverse TNC or reverse SMA) is provided.

Hard-wired Network Connection In a hard-wired, fixed-mount application, the VRC connects to the LAN and server by connecting a cable to the NET connector on the computer’s rear panel. The VRC 4000 supports Token Ring and Ethernet connections.

Token Ring The VRC system can be configured to support a 16 megabyte per second (Mbps) Token Ring connection. Set-up Parameters If your are using an Intel Token Express PCLA8130 connection (factoryinstalled default), the following parameters must be specified: Memory : not used I/O Address : A20-A3FH Int : IRQ 5 No DMA Programmed I/O

2-4

Page 21

Chapter 2: Installation and Maintenance

Ethernet When specified to use Ethernet connections, the VRC system is supplied with the appropriate Ethernet adapter which operates with most network adapters that comply with IEEE 802.3 10Base2 (thin coax), 10Base5 (thick coax) or 10BaseT (twisted pair) standards. If you are using an Intel ethernet card, part number PCLA8120, Etherexpress 16TP (factory-installed default), then the following parameters must be set: I/O address Int Connector Forces 8-bit No RAM mapped Flash/boot ROM Address No Flash Remote Boot Program

: : : :

340-34FH IRQ 5 Auto-detect No

:

Disabled

Wireless Network Connections In wireless applications, the radio link between the VRC and hard-wired network access points provides the network connection. The VRC is equipped with Symbol’s Spectrum 24 2.4 GHz spread-spectrum radio transceiver and antenna which provide the link to strategically-located network access points which are hard-wired into the network. These access points provide overlapping RF coverage (cells) within a building or other facility which enables uninterrupted network communications regardless of vehicle location. Line-of-sight configurations are recommended whenever possible. A site survey should be performed to measure the link quality and received signal strengths prior to permanently mounting the access points. For detailed information regarding the planning of a wireless network, please contact Symbol Technologies directly.

Spectrum 24 Network Set-up Note: Refer to the Spectrum 24 User Documentation for more specific information on how to configure your network.

2-5

Page 22

VRC 4000 Product Reference Guide

In configuring a Spectrum 24 network for use with your VRC 4040 computer, there are specific parameters in the netcfg file which must be set. • SOCKET: indicates the PCMCIA socket in which the adapter is installed

Syntax:

SOCKET N where N is the socket number (1 or 3 for ISA adapters) • UNITYPE:indicates the internal configuration of the driver for the Mobile

Unit type. Syntax:

UNITYPE N where N is the type in hex. (0x2000 for ISA adapters)

Verifying Spectrum 24 Card Installation Debug.exe can be used to verify the network card installation and set-up, by entering the following: C:\>debug -I 300 24 -D000:800 D000:0800 41 FF 00 FF..... -Q When you perform these tests, replace the value 300 with your port number and replace D000 with your memory address. The expected value from the port request is 24 and the expected memory information is 41 FF 00. If you see these values, your system is configured properly.

Connecting External/Optional Equipment With the exception of the antenna connection for wireless operation, all connections to the VRC system are made via connectors on the rear panel.

2-6

Page 23

Chapter 2: Installation and Maintenance

LPT1 Parallel Port COM1 Serial Port

Locking Keyboard Port

P/S-2 Keyboard Dinn Connector

Network Connection (Standard RJ-45) Speaker Microphone

DC PWR Port

PCMCIA Card Slot

Reset Switch

COM2 Serial Port

RF Connection

Mouse Connector

Audio Indicator

Figure 2-1. Rear Panel Connectors

DC Power Connector The DC power connector is a locking 3-pin connector that accepts +12VDC from either a wall-mounted power supply in fixed-mount installations, or the DC power converter in mobile, wireless installations. The power converter connector is a locking type. Remove by pulling back the connector shell. Do not attempt to remove the power supply connector by unscrewing the strain relief.

2-7

Page 24

VRC 4000 Product Reference Guide

Table 2-1. DC Connector Pinout Pin

Signal

1

No connection

2

GND (+12V return; NOT chassis ground)

3

+12VDC

2

3

1

Figure 2-2. DC Power Connector Pinout

2-8