Chapter 1: TWDriver Touchscreen Driver for Windows

DataBits=8 StopBits=1 IRQshare=Off IRQreArm=Off AutoReInit=On Path=. PacketsToIgnore=0

7, 8 1, 2 On, Off On, Off On, Off A DOS directory pathname 1 - 20

UserMode1=n n n n n n UserMode2=n n n n n n UserMode3=n n n n n n UserMode4=n n n n n n CurrentUserMode=n

0,1,2,4,8,16,32,64 (x6) 0,1,2,4,8,16,32,64 (x6) 0,1,2,4,8,16,32,64 (x6) 0,1,2,4,8,16,32,64 (x6) 1-4

ButtonDown1 - ButtonUp3 are only processed if ButtonMode is 0. Path specifies the pathname of the calibration file. If this option is not used, the TWcalib file will reside in the Windows directory. This option may be used to locate it elsewhere. PacketsToIgnore specifies a number of coordinate packets to ignore before sensing a touchdown. The default value is zero. This can be useful in touchdown mode, where the touchdown position is the position of the button click. If the touchscreen takes a few packets to stabilize on the correct position, this parameter can be used to ignore the first few inaccurate packets. This feature is not supported by the configuration control program. The touch triggers for the User Defined Button Modes are defined by numbers, as follows: 0

None ie The mouse event will never occur

1

Immediate ie The mouse event will occur immediately

2

Touchdown ie The mouse event will occur on touchdown

4

Liftoff ie The mouse event will occur on liftoff 1-25

Page 36

VRC 4000 Software Driver Manual

8

Time ie The mouse event will occur on stationary touch

16

Tap ie The mouse event will occur on tapping the screen

32

Z press ie The mouse event will occur on increasing pressure

64

Z release ie The mouse event will occur on decreasing pressure

An even further range of possibilities is available here than in the control program: Touch events can be OR'ed by adding their configuration numbers together. So, for example, the value 24 would define a trigger of Time OR Tap. The default BaudRate, Parity, DataBits and StopBits are touchscreen dependent. IRQshare and IRQreArm are mutually exclusive. That is, they should not both be On.

Co-existence with Mice TWdriver operates with a touchscreen alone if no mouse hardware is present, or with a mouse alone if no touchscreen is present, or with both together if both are present. TWdriver supports all types of Microsoft and IBM PS/2 mice, and 100% hardware compatibles. However, since Windows can only load one mouse driver at a time, it is not possible to provide simultaneous support for mice which require their own special Windows driver.

Co-existence with DOS TBdriver In Windows Real and Standard modes, TBdriver (and TBmouse, if required) may be left resident while Windows runs if desired. They will be disabled while Windows is running, but restored to operation when Windows terminates or executes a Dos shell.

1-26

Page 37

Chapter 1: TWDriver Touchscreen Driver for Windows

However, in Windows Enhanced mode, each virtual machine is a perfect copy of the machine environment which Windows finds when it starts up, including any TSR's. Windows continues to reflect serial interrupts into TBdriver, as well as TWdriver, with the result that the Windows driver loses data and performance of the touchscreen is severely degraded. For this reason, TBdriver must not be loaded when Windows is started in Enhanced mode.

Troubleshooting and Technical Support The control program 'TWsetup' displays an 'About' box which amongst other things, shows the initialization status and whether calibration is valid for the installed TWdriver. If the initialization status is anything other than 'Ok' read on... if the calibration status is anything other than 'Ok', this represents the DOS error encountered when TWdriver attempted to access the calibration data - try re-calibrating. If the communications errors are anything other than zero read on.... In case of difficulty, the following checks should be made before calling technical support:

No cursor movement when touchscreen touched • Check that the touchscreen has power, and that its communication cable is connected to the computer. • Check that the switch settings, if any, are set as specified in ’Switch

Settings and Hardware Notes’. • Check that you selected the correct driver for your touchscreen in the

Windows Setup program. • Check that the TWdriver hardware configuration is set up correctly. For serial touchscreens check that TWdriver is configured for the correct serial port number. For COM3, COM4, and bus controller touchscreens, check that the port address and IRQ are configured to match the hardware switch or jumper settings. Also check for port address or IRQ conflicts with other cards in the system.

Cursor moves but incorrectly • Check that you have calibrated, and that TWdriver still has access to the

1-27

Page 38

VRC 4000 Software Driver Manual

TWcalib calibration file, either in the Windows directory, or via the Path setting in WIN.INI. • If you have re-installed TWdriver for a different type of touchscreen, you will need to re-calibrate.

Difficulties with double clicks • Ensure that Windows' mouse double click speed is set to slow, as described in the ’Getting Started’ section. • You may have set the TWdriver settings for ClickTime or Sensitivity to time intervals so great that two clicks take longer than the time allowed by the Windows DoubleClickSpeed setting. If you have set high values for ClickTime or Sensitivity, try reducing them.

System performance • If your touchscreen requires software initialization, and is powered off,

TWdriver will attempt to re-initialize it every ten seconds, which may degrade system performance. This can be prevented by specifying AutoReInit=Off in WIN.INI, or using the TWsetup program. • If you are running Windows in 386 enhanced mode, and you left a DOS touchscreen driver running when you started Windows, Windows will reflect serial interrupts into that as well as TWdriver, which will severely degrade touch responses.

TBdiag - The Touchscreen Diagnostic Program The TBdiag program is provided on the distribution diskette for the more technically minded user, to help identify communication problems with serial touchscreens, or simply to observe the raw data from the touchscreen. TBdiag is a DOS program, and is invoked from the DOS command line by typing TBdiag. Its monitor screen shows data sent to and received from the touchscreen, allowing you to see if it is responding to the initialization sequence, and if it is sending any coordinate data at all. You can re-try the initialization sequence at any time by pressing 'I', switch to hex display mode by pressing 'H', and exit by pressing 'X'. TBdiag takes several optional parameters:

1-28

Page 39

Chapter 1: TWDriver Touchscreen Driver for Windows

The TBdiag Command Line TBdiag [Port] [/C:bbbb,p,d,s] [/A:address] [/I:irq] [/NI] [/G]

Port /C:bbbb,p,d,s bbbb p d s /A:address /I:irq /NI /G

Specifies a serial port (1 .. 8) Communications parameters: Baud rate (1200, 2400, 4800, 9600) Parity (N, O, E) Databits (7, 8) Stopbits (1, 2) Port address (hexadecimal) Interrupt request number (0 .. 15) No initialization. Do not initialize touchscreen. Perform Global rearming

TBdiag /?

Prints the above summary

Most of these options are only rarely required. In most cases all that is required is simply: TBdiag 1 TBdiag 2

For a touchscreen on COM1, or: For a touchscreen on COM2.

Example TBdiag /C:4800,e,7,2 /A:748 /I:10 /NI

Load TBdiag on a COM port at address 748 hex, using irq 10, at 4800 baud, even parity, 7 data bits, 2 stop bits. Do not perform touchscreen initialization. A large window shows data sent to and received from the touchscreen, while the lower window shows the status, mainly of the serial port. Interpretation of much of the information given by TBdiag requires specialist knowledge of serial ports and the touchscreen data stream. However, a working touchscreen should always show a data stream of some kind when touched.

1-29

Page 40

VRC 4000 Software Driver Manual

Before Calling Technical Support Please have the following information available (most can be found in TWsetup's 'About' box) before calling Technical Support: • TWdriver version number • Touchscreen manufacturer and type • Touchscreen communications hardware configuration • Windows version number, and modes affected • DOS manufacturer and version number

Please also have the TWdriver distribution diskette to hand, as we may ask you to load and run TBdiag.

1-30

Page 41

Chapter 1: TWDriver Touchscreen Driver for Windows

Service Information If you have a problem with your equipment, contact the Symbol Support Center. Call the Support Center from a phone near the equipment so that the service person can try to talk you through your problem. If your problem cannot be solved over the phone, you may need to return your equipment for servicing. If that is necessary, you will be given specific directions. Note:

Symbol Technologies is not responsible for any damages incurred during shipment if the approved shipping container is not used. Shipping the units improperly can possibly void the warranty. If the original shipping container was not kept, contact Symbol to have another sent to you.

Symbol Support Center For service information, warranty information or technical assistance, call:

USA SYMBOL SUPPORT CENTER 1-800-653-5350

Canada Mississauga, Ontario Canadian Headquarters (905) 629-7226

Europe Wokingham, England European Headquarters 0734-771-222 (Inside UK) +44-1734-771222 (Outside UK)

1-31

Page 42

VRC 4000 Software Driver Manual

Asia Singapore Symbol Technologies Asia, Inc. 337-6588 (Inside Singapore) +65-337-6588 (Outside Singapore) If you purchased your Symbol product from a Symbol Business Partner, contact that Business Partner for service.

1-32