The text of a manual · part 14 of 18
PDT 7200 Series Product Reference Guide for Windows CE 3.0: Appendix A Specifications
Pages 109 to 112 of 142, from PDT 7200 Series Product Reference Guide for Windows CE 3.0
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol PDT-7200
Page 109
Appendix A Specifications Environment The PDT 7200 is designed to operate in harsh environments. Table A-1 below summarizes the PDT 7200’s intended operating environment. Table A-1. PDT 7200 Operating Environment Operating Temperature
-20° C to 50° C (-4° F to 122° F)
Humidity
0% to 95% non-condensing
Shipping and Storage Temperature
-30° C to 60° C (-22° F to 140° F)
Electrostatic Discharge
±15 kv
Drop to Concrete
1.4 meters (4 ft.) 1.8 meters (6 ft.) with optional rubber boot
Sealing
IP 54 and IPC 529 (splashing water and dust)
A-1
Page 110
PDT 7200 Series Product Reference Guide for Windows® CE
Decode Zones Standard Range 11.7 29.75 Integrated Scanner
5
12.7
0
0
5
12.7
.005 In. Depth of Field in Inches
.0075 In. .020 In. Minimum Element Width .040 In. Minimum Element Width .055 In. Minimum Element Width 0 12 0
4
6 12.7
8
11.7 29.75 In. Cm.
Width of Field in Inches / Centimeters
NOTE: Typical performance at 68o F ( 20o C) on high quality symbols.
In. 10 12 14 16 18 20 22 24 26 28 30 32 34 25.4 38.1 50.8 63.5 76.2 86.4 Cm.
Decode Zone: Depth of field as a function of minimum element width.
Long Range 11.7 29.75 Integrated Scanner
.010 In.
Depth of Field in Inches
.015 In. Min. .020 In. Minimum Element Width .040 In. Minimum Element Width .055 In. Minimum Element Width 0 0
5
10 15 20 25 30 35 40 45 50 25.4 50.8 76.2 101.6 127
12.7
0
0
5
12.7
11.7 29.75 In. Cm.
55
60 65 70 In. 152.4 177.8 Cm.
Long Range Decode Zone: Depth of field as a function of minimum element width.
A-2
5
Width of Field in Inches / Centimeters
NOTE: Typical performance at 68o F ( 20o C) on high quality symbols.
Page 111
Specifications
NOTE: Typical performance at 68o F ( 20o C) on high quality symbols. Y-module dimension = 3 X.
10
25.4
5
12.7
0
0
5
12.7
8 10
25.4
In.
Cm.
8 6 Integrated Scanner
4 2 2 4
.006 In.
Depth of Field in Inches
6
.0075 In. .020 In. Min. Element Width .040 In. Minimum Element Width .055 In. Minimum Element Width 0 12 0
4
6 12.7
8
10 12 14 16 18 20 22 24 26 28 30 32 25.4 38.1 50.8 63.5 76.2
Width of Field in Inches / Centimeters
SE 2000 1-D Decode Zone
In. Cm.
SE 2000 Decode Zone: Depth of field as a function of minimum element width.
Integrated Scanner
Depth of Field in Inches
4
10.2
2
5.1
0
0
2
5.1
4
10.2
.0066 In. .010 In. Minimum Element Width
In. Cm.
.015 In. Minimum Element Width 0 1 2 0 2.5 5.1
4 10.1
6 15.2
8 20.3
10 25.4
12 30.5
14 35.6
Width of Field in Inches / Centimeters
SE 2000 2-D Decode Zone (PDF417)
In. Cm.
A-3
Page 112
PDT 7200 Series Product Reference Guide for Windows® CE
Pin-Outs Pin
Description
1
GND
2
DSR
3
RXD
4
CTS
5
DCD
6
GND
7
PWROUT (+5V)
8
Reserved
9
DTR
10
Ring
11
TXD
12
RTS
13
Reserved
14
GND
15
Reserved
A-4