Page 89

Configuring the Terminal

Pressing Enter while the copyright screen is displayed advances the program to the Baud Rate Menu. Baud Rate Run System 2400 4800 9600 19200 38400 57600 115200 Enter

1. Tap the arrows on the touch screen to scroll to the appropriate baud rate. IPL supports baud rates from 2400 to 115200 baud. (default is 115200 baud) 2. Press Enter or the Scan trigger to accept the selected baud rate. Note: If IPL is selected accidentally, or the IPL session is complete, you may select “Run System” from this menu to exit IPL an boot the system. The only other way to exit IPL manually is to hold the Power Icon for 16 seconds. Both methods have the same effect, but selecting “Run System” is faster. Once the selection is made, IPL proceeds to the Area Selection Menu. IPL

Ver x.xx Prev. Menu Single Image Multiple Images Boot Loader Splash Screen Windows CE Core Platform Application Data Exec IPL Partition Map Enter

6-17

Page 90

PDT 7200 Series Product Reference Guide for Windows® CE

3. Use the up and down arrows on the touch screen to select the area to be received. You have the following options on this screen: Prev. Menu

Returns you to the Baud Rate menu to modify the baud rate.

Single Image

Indicates that a single image is to be received, without specifying the area to be received.

Multiple Images (default selection)

Indicates that more than one area is to be received contiguously.

Boot Loader

Indicates that a new Boot Loader is to be received.

Splash Screen

Indicates that a new splash screen is to be received.

Windows CE Core

Indicates that a CE Core is to be received.

Platform Application Data Indicates the specific disk volume(s) to be received. Exec

For factory diagnostic use only.

IPL

For service use only.

Partition Map

Indicates that the partition map is to be received.

4. After selecting the area, press Enter. IPL checks for the presence of external power. If the system is running off battery power, IPL displays the Connect to Power Screen: Insert in Cradle Or Connect Power Supply

5. Place the terminal in the cradle or connect the external power supply and serial connection. IPL waits at this screen until external power is supplied. If the terminal is already running from external power, this screen does not display. While this screen is displayed, pressing Enter or the Cursor Up/Down returns IPL to the Area Selection screen. 6. After the power and serial connections are made, the following screen displays: Waiting for data Multiple Images 115200

6-18

Page 91

Configuring the Terminal

The second and fourth lines of this screen reflect the selections made on the Area Selection and Baud Rate menus, respectively. This screen continues to display until the first character of the image to be downloaded is received from the host. While this screen is displayed, pressing the Enter or Cursor Up/Down keys on the keyboard returns IPL to the Area Selection screen. As soon as the first character of data is received, IPL displays the receiving screen:

Multiple Images Pages to Erase Pages to Receive Pages to Write

The top line of this screen identifies the area selected in the Area Selection screen. Once a character has been received, IPL stays in this screen until an entire image has been received, or until an error is detected. The only other way to exit from this screen is to reset the terminal by holding the power switch down for 16 seconds. As more data is received, the Receiving Screen is updated to reflect the current status. The first record in the image identifies the area to be processed. When IPL receives the record, it verifies that the area is valid, and updates the Receiving screen as follows:

Boot Loader Pages to Erase Pages to Receive Page to Write

16 16 16

The top line of the display identifies the actual area being processed. The remainder of the display identifies the number of 8Kbyte pages to erase, receive and write. To process the data, IPL must receive, erase, and write the entire image. With the exception of the disk images, IPL receives the entire image before starting the erase, and completes the erase before starting to write. With disk images, IPL multiplexes all three operations as data is received. Eventually, (assuming no errors), all three counts reduce to 0.

6-19

Page 92

PDT 7200 Series Product Reference Guide for Windows® CE

When the entire image is received, and the flash is updated, IPL displays the Verify screen: Boot Loader Verifying Image

This screen continues to display while the image is being verified. Once the image is verified, IPL displays the Success screen:

Boot Loader Download Complete No Errors Detected

If the Multiple Images option was selected on the Area Selection screen, IPL then immediately returns to the Waiting for Data screen to wait for the next image. If any other selection was made on the Area Selection screen, then IPL stays at the success screen until the operator acknowledges the message by pressing Enter (or the trigger, or taps Enter on the touchscreen). Once the screen has been acknowledged, IPL returns to the Area Selection screen to wait for a new selection.

IPL Error Detection While receiving data, IPL performs many checks on the data to ensure that the data is received correctly. If any error is detected, IPL immediately aborts the download, and reports the error on an error screen:

Download Failed! Boot Loader Error Message

ENTER

6-20

Page 93

Configuring the Terminal

This screen is displayed until the operator acknowledges the error by pressing Enter (or trigger, or Enter on the touch screen). Once the screen has been acknowledged, IPL returns to the Area Selection screen to wait for a new selection. The second line of the displays the area that was being processed when the error was detected. The third line of the screen identifies the cause of the error. The errors that can be reported, and the probable cause of the error, are as follows: Table 6-1. IPL Errors Error

Explanation

Erase Error

Either the flash is faulty, and the terminal needs to be returned for service, or an attempt was made to erase IPL. (IPL is write-protected, and cannot be erased or programmed without special hardware.)

Line Stat Err

A framing error was detected in the incoming data. The most probable cause of this is a parameter mismatch between the terminal and the device used to transmit the data. The baud rate on both devices must be set to the same value, and the transmitting device must be set to 8 data bits, no parity, and at least one stop bit.

Baud too High

This error could be caused by transmitting large compressed images at a high baud rate, or by faulty flash.

Image Corrupt

This error indicates that the image received by the terminal is corrupt. The most probable cause of this error is inserting an IPL-enabled terminal into a cradle while the host is transmitting an image.

Wrong Area

This error indicates that the image being received has an incorrect area number. This could be caused by specifically selecting an area, and loading an image intended for another area, or by receiving an image for an area that is not defined in the partition map.

Not Hex File

This error is caused by transmitting the wrong file format to IPL. IPL can only receive Hex files supplied by Symbol, or generated by TCM.

Write Error

This error is caused by a failure of the flash device used to hold the image. If this error is seen, then the terminal requires maintenance.

6-21

Page 94

PDT 7200 Series Product Reference Guide for Windows® CE

Table 6-1. IPL Errors (Continued) Error

Explanation

Checksum Err

This error is occurs when one of the critical partitions (Windows® CE Core or Partition Map) has been received with no apparent errors, but the received image does not pass the checksum check. The most probable cause of this error is a failure of the tool used to generate the image. If this error is displayed, then the original contents of the partition will not have been changed as the error is detected before any flash is updated.

Verify Failed:

This error is caused when the image has been written to flash, but cannot be read back correctly. It only applies to critical sections of the flash, and will prevent an exit from IPL as a critical section of the flash is damaged. If this error occurs, the terminal needs maintenance. Contact Symbol Support for help.

Lost Connection

This error displays when the terminal is removed from the cradle during an IPL session. The terminal should be replaced in the cradle when the host is no longer transmitting an image, and the image should be resent to the terminal that lost the connection. Disconnecting the serial cable does not generate this error, and attempting to reconnect the cable will result in an Image Corrupt error.

Cradle Error

This error indicates that corrupted data is being continually received from the cradle. The most probable cause of the error is an obstruction on the IrDA window on the terminal or the cradle. If cleaning the windows fails to correct the problem, then the terminal requires service. Contact Symbol Support for help.

To exit and restart IPL, hold the PWR key for 16 seconds.

Restarting after Download Fails If the download fails, exit IPL by rebooting the terminal. If possible, determine what caused the download to fail. If a communications failure occurred, check all the cables between the terminal and the host to ensure they are secure. If the hex file is too large to fit in the terminal’s Flash disk, reset the hex file’s size (refer to Defining Script Properties on page 6-7) and rebuild the image.

6-22

Page 95

Configuring the Terminal

Exiting IPL To exit IPL, cold boot the terminal by holding the PWR icon for 16 seconds. The terminal boots to an application or to a login screen.

Exiting TCM To exit TCM on the development PC: Choose Exit from the File Menu. OR Press Alt+F4. OR Double-click the close box.

6-23

Page 96

PDT 7200 Series Product Reference Guide for Windows® CE

6-24