PC104 Interface The MG+ 486 accommodates one PC104 16/8 bit card.

PCMCIA Interface The MG+ 486 accommodates up to two 5V PCMCIA cards (if both slots are used, a type 3 card may be installed in the top slot only). The interface supports hot plug-in.

Backup Battery The MG+ 486 accommodates an 8.4V 500ma NiCd backup battery (J2). The backup battery provides power during brownout periods and backs up the RTCs when main power is not available. The battery is not user-serviceable.

Installing the MG+ 486 Caution:

Improper installation can cause damage to both the vehicle and the MG+ 486. Installation should be performed by an experienced technician.

To install the MG+ 486: 1. Select a mounting location that is flat and provides adequate support and ventilation for the MG+ 486. Note:

The MG+ 486 chassis must be grounded to the vehicle chassis.

2. Secure the MG+ 486 with appropriate nuts and bolts. Selflocking nuts or lock washers must be used. 3. Connect the power cable. 4. Route the power cable to the battery power source. 5. Connect the V+ wire to the battery power source, splicing a fuseholder with a 10 amp fuse in-line with the power source.

5

Page 8

M G +

Note:

4 8 6

Locate the fuse as close as possible to the battery power source.

6. Connect the Vehicle Accessory Power to the vehicle accessory bus, splicing a fuseholder with a 1 amp fuse in-line with the accessory power source. Note:

Locate the fuse as close as possible to the accessory power source.

The accessory bus is the ‘switched’ power source controlled by the ignition key. Connect the power cable to the power source using appropriate connectors. 7. Place a CAUTION label on each fuseholder. 8. Plug the circular connector into the +12/24 VDC connector on the MG+ 486. Voltage & Current Requirements Input Voltage

+12/24 VDC

V+ Input Current

4.5 A Max

Accessory Power Input Current

10 mA

6

Page 9

Q u i c k

R e f e r e n c e

Service Information Before you use the unit, it must be configured to operate in your facility’s network and run your applications. If you have a problem running your unit or using your equipment, contact your facility’s Technical or Systems Support. If there is a problem with the equipment, they will contact the Symbol Support Center:

United States

1-800-653-5350

Canada

905-629-7226

United Kingdom 0800 328 2424

Asia/Pacific 337-6588

Australia

1-800-672-906

Austria

Denmark

7020-1718

Finland

9 5407 580

France

01-40-96-52-21

Germany

6074-49020 5-520-1835

1-505-5794

Italy

2-484441

Mexico

Netherlands

315-271700

Norway

66810600

South Africa

11-4405668

Spain

9-1-320-39-09

Sweden

84452900

Latin America Sales Support

1-800-347-0178 Inside US +1-561-483-1275 Outside US

Europe/Mid-East Distributor Oper- Contact local distributor or call ations +44 118 945 7360

Warranty Symbol Technologies, Inc. (“Symbol”) manufactures its hardware products in accordance with industry-standard practices. Symbol warrants that for a period of twelve (12) months from date of shipment, products will be free from defects in materials and workmanship. This warranty is provided to the original owner only and is not transferable to any third party. It shall not apply to any product (i) which has been repaired or altered unless done or approved by Symbol, (ii) which has not been maintained in accordance with any operating or handling instructions supplied by Symbol, (iii) which has been subjected to unusual physical or electrical stress, misuse, abuse, power shortage, negligence or accident or (iv) which has been used other than in accordance with the product operating and handling instructions. Preventive maintenance is the responsibility of customer and is not covered under this warranty. Wear items and accessories having a Symbol serial number, will carry a 90-day limited warranty. Non-serialized items will carry a 30-day limited warranty.

7

Page 10

M G +

4 8 6

Warranty Coverage and Procedure During the warranty period, Symbol will repair or replace defective products returned to Symbol’s manufacturing plant in the US. For warranty service in North America, call the Symbol Support Center at 1-800-653-5350. International customers should contact the local Symbol office or support center. If warranty service is required, Symbol will issue a Return Material Authorization Number. Products must be shipped in the original or comparable packaging, shipping and insurance charges prepaid. Symbol will ship the repaired or replacement product freight and insurance prepaid in North America. Shipments from the US or other locations will be made F.O.B. Symbol’s manufacturing plant. Symbol will use new or refurbished parts at its discretion and will own all parts removed from repaired products. Customer will pay for the replacement product in case it does not return the replaced product to Symbol within 3 days of receipt of the replacement product. The process for return and customer’s charges will be in accordance with Symbol’s Exchange Policy in effect at the time of the exchange. Customer accepts full responsibility for its software and data including the appropriate backup thereof. Repair or replacement of a product during warranty will not extend the original warranty term. Symbol’s Customer Service organization offers an array of service plans, such as on-site, depot, or phone support, that can be implemented to meet customer’s special operational requirements and are available at a substantial discount during warranty period.

General Except for the warranties stated above, Symbol disclaims all warranties, express or implied, on products furnished hereunder, including without limitation implied warranties of merchantability and fitness for a particular purpose. The stated express warranties are in lieu of all obligations or liabilities on part of Symbol for damages, including without limitation, special, indirect, or consequential damages arising out of or in connection with the use or performance of the product. Seller’s liability for damages to buyer or others resulting from the use of any product, shall in no way exceed the purchase price of said product, except in instances of injury to persons or property. Some states (or jurisdictions) do not allow the exclusion or limitation of incidental or consequential damages, so the proceeding exclusion or limitation may not apply to you.

8

Page 11

Q u i c k

R e f e r e n c e

Regulatory Information Radio Frequency Interference Requirements This device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the Federal Communications Commissions Rules and Regulation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This device complies with FCC Part 15. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.

Radio Frequency Interference Requirements - Canada This device complies with RSS 210 of Industry & Science Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Industry Canada Standard ICES-003. Cet appareil numérique de la classe B est conform à la norme NMB-003 d’Industrie Canada.

CE Marking and European Union Compliance Products intended for sale within the European Union are marked with the CE Mark which indicates compliance to applicable Directives and European Normes (EN), as follows. Amendments to these Directives or ENs are included:

9

Page 12

Applicable Directives • Electromagnetic Compatibility Directive 89/336/EEC • Low Voltage Directive 73/23/EEC

Applicable Standards • EN 55022:1998, Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment • EN 55024:1998; Information Technology equipment - Immunity characteristics Limits and methods of measurement • IEC 1000-4-2:1995; Electromagnetic compatibility (EMC); Part 4:Testing and measurement techniques; Section 4.2:Electrostatic discharge immunity test • IEC 1000-4-3:1997; Electromagnetic Compatibility (EMC); Part 4:Testing and measurement techniques; Section 3. Radiated, radio frequency, electromagnetic field immunity test. • IEC 1000-4-4:1995; Electromagnetic compatibility (EMC); Part 4: Testing and measurement techniques; Section 4:Testing electrical fast transient,/Burst immunity. • IEC1000-4-5:1995; Electromagnetic compatibility (EMC), Part 4: Testing and measurement techniques; Section 5: Surge Immunity • IEC 1000-4-6:1996; Electromagnetic compatibility (EMC), Part 4:Testing and measurement techniques; Section 6: Immunity to conducted disturbances, induced by radio frequency fields. • IEC 1000-4-11:1994; Electromagnetic compatibility (EMC), Part 4: Testing and measurement techniques; Section 11: Voltage Dips, Short Interruptions, and Voltage Variations. • EN 60 950 + A1+A2+A3+A4+A11 - Safety of Information Technology Equipment Including Electrical Business Equipment • EN 60 825-1 (EN 60 825) - Safety of Devices Containing Lasers

72-40689-01 Revision A, January 2000 Symbol Technologies, Inc. One Symbol Plaza Holtsville, NY 11742-1300