Page 71
Programming the LS 6800
I 2 of 5 Check Digit Verification When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies a specified algorithm, either Uniform Symbology Specification (USS), or Optical Product Code Council (OPCC).
<FN3>2051E00 DISABLE
<FN3>2051E02
OPCC CHECK DIGIT
USS CHECK DIGIT <FN3>2051E01
5-31
Page 72
LS 6800 Product Reference Guide
Transmit I 2 of 5 Check Digit Scan a bar code below to transmit data with or without the check digit.
<FN3>1020211 TRANSMIT I 2 of 5 CHECK DIGIT (ENABLE)
DO NOT TRANSMIT I 2 of 5 CHECK DIGIT (DISABLE) <FN3>1020210
5-32
Page 73
Programming the LS 6800
Convert I 2 of 5 to EAN-13 This parameter converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. In order to accomplish this, the I 2 of 5 code must be enabled, one length must be set to 14, and the code must have a leading zero and a valid EAN-13 check digit.
<FN3>1020201 CONVERT I 2 of 5 to EAN-13 (ENABLE)
DO NOT CONVERT I 2 of 5 to EAN-13 (DISABLE) <FN3>1020200
5-33
Page 74
LS 6800 Product Reference Guide
MSI Plessey Check Digits These check digits at the end of the bar code verify the integrity of the data. At least one check digit is always required. Check digits are not automatically transmitted with the data (see below).
Transmit MSI Plessey Check Digit Scan the appropriate bar code below to transmit the data with or without the check digit.
<FN3>1020120
TRANSMIT MSI PLESSEY CHECK DIGIT (DISABLE) TRANSMIT MSI PLESSEY CHECK DIGIT (ENABLE) <FN3>1020131
5-34
<FN3>1020121
TWO MSI PLESSEY CHECK DIGITS
<FN3>1020130
ONE MSI PLESSEY CHECK DIGIT
Page 75
Programming the LS 6800
MSI Plessey Check Digit Algorithm When the two MSI Plessey check digits option is selected, an additional verification is required to ensure integrity. Either of the two following algorithms may be selected.
<FN3>1020230 MOD 10/MOD11
MOD 10/MOD10 <FN3>1020231
5-35
Page 76
LS 6800 Product Reference Guide
Convert EAN-8 to EAN-13 This parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.
<FN3>1020201 ENABLE CONVERT EAN-8 TO EAN-13
DISABLE CONVERT EAN-8 TO EAN-13 <FN3>1020200
5-36
Page 77
Programming the LS 6800
Decode UPC/EAN Supplemental Select whether UPC/EAN is decoded with or without supplemental characters. Supplementals are additionally appended characters (2 or 5) according to specific code format conventions (e.g., UPC A+2, UPC E+2, EAN 8+2). t If UPC/EAN with supplemental characters is selected, UPC/EAN symbols without supplemental characters won't be decoded. t If UPC/EAN without supplemental characters is selected and the scanner is presented with a UPC/EAN plus supplemental symbol, the UPC/EAN is decoded and the supplemental characters ignored. t If autodiscrimination is chosen, the LS 6800 scanner transmits either, after additional processing to ensure a good decode. Note: To minimize the risk of invalid data transmission, it is recommended that you select whether to read or ignore supplemental characters.
<FN3>2010E01 DECODE UPC/EAN SUPPLEMENTALS <FN3>2016E00
IGNORE UPC/EAN SUPPLEMENTALS
AUTODISCRIMINATE UPC/EAN SUPPLEMENTALS <FN3>201E02
5-37
Page 78
LS 6800 Product Reference Guide
CLSI Editing When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Note: Symbol length does not include start and stop characters
NOTIS Editing When enabled, this parameter strips the start and stop characters from decoded Codabar symbol.
<FN3>1020051
DISABLE NOTIS EDITING
ENABLE NOTIS EDITING <FN3>1020061
5-38
<FN3>1020050
DISABLE CLSI EDITING
<FN3>1020060
ENABLE CLSI EDITING
Page 79
Programming the LS 6800
Transmit Code ID Character A code ID character identifies the code type of a scanned bar code, useful when the scanner is decoding more than one code type. If a prefix is selected, the code ID character is sent after the prefix and before the decoded symbol. You may select no code ID character, a Symbol code ID character, or an AIM ID character. Symbol code ID characters are listed below. AIM ID characters are listed in Appendix A, Programming Reference. Table 5-3. Symbol Code Identifiers Code Type
Symbol Identifier
UPC-A, UPC-E, EAN-13, EAN-8
A
Code 39
B
Codabar
C
Code 128
D
Code 93
E
Interleaved 2 of 5
F
Discrete 2 of 5, D 2 of 5 IATA
G
MSI Plessey
J
UCC/EAN 128
K
Bookland EAN
L
Trioptic Code 39
M
PDF417, MicroPDF417
X
5-39
Page 80
LS 6800 Product Reference Guide
Transmit Code ID Character (Cont’d)
<FN3>2051702 TRANSMIT SYMBOL CODE ID CHARACTER
<FN3>2051700
5-40
<FN3>2051701
TRANSMIT AIM CODE ID CHARACTER
DO NOT TRANSMIT CODE ID CHARACTER