Page 161

Advanced Data Formatting

Pad Data With Zeros To pad data to the left, scan the bar code containing the desired number of zeros. This parameter is activated by Send commands.

Beeps Select a beep sequence for each ADF rule.

Send Keystroke (Control Characters and Keyboard Characters) Scan the “Send __” bar code for the keystroke you wish to send.

Turn On/Off Rule Sets Use these bar codes to turn rule sets on and off.

6-7

Page 162

LS 6800 Product Reference Guide

ADF Bar Code Menu Example This section provides an example of how ADF rules are entered and used for scan data. An auto parts distribution center wants to encode manufacturer ID, part number, and destination code into their own Code 128 bar codes. The distribution center also has products that carry UPC bar codes, placed there by the manufacturer. The Code 128 bar codes have the following format: MMMMMPPPPPDD Where:

M = Manufacturer ID P = Part Number D = Destination Code

The distribution center uses a PC with dedicated control characters for manufacturer ID <CTRL M>, part number <CTRL P>, and destination code <CTRL D>. At this center the UPC data is treated as manufacturer ID code. The following rules need to be entered: When scanning data of code type Code 128, send the next 5 characters, send the manufacturer ID key <CTRL M>, send the next 5 characters, send the part number key <CTRL P>, send the next 2 characters, send the destination code key <CTRL D>. When scanning data of code type UPC/EAN, send all data, send the manufacturer ID key <CTRL M>. To enter these rules, follow the steps below:

6-8

Page 163

Advanced Data Formatting

Rule 1:The Code 128 Scanning Rule Step

Bar Code

On Page

Beep Indication

1

Begin New Rule

7-1

High High

2

Code 128

7-5

High High

3

Send next 5 characters

7-14

High High

4

Send <CTRL M>

7-34

High High

5

Send next 5 characters

7-14

High High

6

Send <CTRL P>

7-35

High High

7

Send next 2 characters

7-14

High High

8

Send <CTRL D>

7-33

High High

9

Save Rule

7-2

High Low High Low

Rule 2:The UPC Scanning Rule Step

Bar Code

On Page

Beep Indication

1

Begin New Rule

7-1

High High

2

UPC/EAN

7-6

High High

3

Send all remaining data

7-14

High High

4

Send <CTRL M>

7-34

High High

5

Save Rule

7-2

High Low High Low

If you made any mistakes while entering this rule, scan the QUIT ENTERING RULES bar code on page 7-3. If you already saved the rule, scan the ERASE PREVIOUSLY SAVED RULE bar code on page 7-2.

6-9

Page 164

LS 6800 Product Reference Guide

Alternate Rule Sets ADF rules may be grouped into one of four alternate sets which can be turned on and off when needed. This is useful when you want to format the same message in different ways. For example, a Code 128 bar code contains the following information: Class (2 digits), Stock Number (8) digits, Price (5 digits) This bar code might look like this: 245671243701500 where: Class = 24 Stock Number = 56712437 Price = 01500 Ordinarily you would send this data as follows: 24 (class key) 56712437 (stock key) 01500 (enter key) But, when there is a sale, you may want to send only the following: 24 (class key) 56712437 (stock key) and the cashier will key the price manually. To implement this, you would first enter an ADF rule that applies to the normal situation. This rule may look like this: When scanning a bar code of length 15, send the next 2 characters, send the class key, send the next 8 characters, send the stock key, send the data that remains, send the Enter key. The “sale” rule may look like this: When scanning a bar code of length 15, send the next 2 characters, send the class key, send the next 8 characters, send the stock key. To switch between the two sets of rules, a “switching rule” must be programmed. This rule specifies what type of bar code must be scanned to switch between the rule sets. For example,

6-10

Page 165

Advanced Data Formatting in the case of the “sale” rule above, the rule programmer wants the cashier to scan the bar code “M” before a sale. To do this, a rule can be entered as follows: When scanning a bar code of length 1 that begins with “M”, select rule set number 1. Another rule could be programmed to switch back. When scanning a bar code of length 1 that begins with “N”, turn off rule set number 1. The switching back to normal rules can also be done in the “sale” rule. For example, the rule may look like this: When scanning a bar code of length 15, send the next 2 characters, send the class key, send the next 8 characters, send the stock key, turn off rule set 1. It is recommended that you scan the Disable All Rule Sets bar code after programming a rule belonging to an alternate rule set. In addition to enabling and disabling rule sets within the rules, you can enable or disable them by scanning the appropriate bar codes on Code Lengths on page 7-7.

Rules Hierarchy (in Bar Codes) The order of programming individual rules is important.The most general rule should be programmed last. All programmed rules are stored in a buffer. As they are programmed, they are stored at the “top” of a rules list. If three rules have been created, the list would be configured as follows: Third Rule Second Rule First Rule When data is scanned, the rules list is checked from top to bottom to determine if the criteria matches (and therefore, if the actions should occur). Input is modified into the data format specified by the first matching set of criteria it finds. Be sure that your most general rule is the last one programmed. For example, if the THIRD rule states: When scanning a bar code of any length, send all data, then send the ENTER key. And the SECOND rule states: When scanning a Code 128 bar code of length 12, send the first four characters, then send the ENTER key, then send all remaining data.

6-11

Page 166

LS 6800 Product Reference Guide

If a Code 128 bar code of length 12 were scanned, the THIRD rule would be in effect. The SECOND rule would appear to not function. Note also that ADF rules are actually created when you use the standard data editing functions. Scan options are entered as ADF rules, and the hierarchy mentioned above also applies to them. For the LS 6800, this applies to prefix/suffix programming in the parameter Scan Data Transmission Format. These rules reside in the same “rule list” as ADF Rules, so the order of their creation is also important.

Default Rules Every unit has a default rule to send all scan data. Units with custom software may have one or more default rules burned in. The rules hierarchy checks user programmable rules first, then the default rules. Default rules can be disabled by entering the following general rule in the user programmable buffer: When receiving scan data, send all data. Since this rule always applies, ADF will never go into the default rules.

6-12

Page 167

Advanced Data Formatting

Beeper Definitions The following table defines beep sequences which occur during data entry. Table 6-1. Beeper Definitions Normal Data Entry. Duration of tones are short. Beeper Sequence

Indication

High-Low

Entry of a number is expected. Enter another digit. Add leading zeros to the front if necessary.

Low-Low

Entry of an alphabetic character is expected. Enter another character or scan the End of Message bar code.

High-High

Entry of Criterion/Action is expected. Enter another criterion or action, or scan the Save Rule bar code.

High-Low-High-Low

Rule saved. Rule entry mode exited.

High-Low-Low

All criteria or actions were cleared for rule currently being entered; continue entry of rule.

Low

Last saved rule was successfully deleted. The rule presently being entered is left intact.

Low-High-High

All rules are now deleted. The rule presently being entered is left intact. (This beep sequence has a different meaning outside of ADF.)

Error Indications. Duration of tones are very long. Beeper Sequence

Indication

Low-High-Low-High

Out of rule memory. Erase some existing rules, then try to save rule again. (The current rule need not be re-entered.)

Low-High-Low

Cancel rule entry. Rule entry mode exited because of an error or the user asked to exit rule entry.

Low-High

Entry error, wrong bar code scanned. Re-enter criterion or action. All previously entered criteria and actions are retained. Criteria or action list is too long for a rule.

6-13

Page 168

LS 6800 Product Reference Guide

6-14

Page 169

Chapter 7 ADF Bar Codes Due to the large number of Advanced Data Formatting bar codes, the page layout of this chapter is not as in Chapter 5. When scanning a bar code in this chapter, cover up unwanted bar codes in the scanning area. If you have difficulty programming ADF using this method, contact 1-800 - 92SYMBOL, extension 4417.

Special Commands Begin New Rule Scan this bar code to start entering a new rule.

<FN3>7B1211 BEGIN NEW RULE

7-1

Page 170

LS 6800 Product Reference Guide

Save Rule Scan this bar code to save the rule you entered.

<FN3>4 SAVE RULE

Erase Use these bar codes to erase criteria, actions, or rules.

<FN3>6C-

<FN3>6A-

ERASE CRITERIA AND START AGAIN

ERASE ACTIONS AND START AGAIN

<FN3>81 ERASE PREVIOUSLY SAVED RULE

7-2