Page 131

Programming the LS 6800

Intercharacter Delay Select the intercharacter delay option matching host device requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. Select from no delay to a 99 ms delay between the transmission of each character. To set a host communications intercharacter delay: 1. Scan the INTERCHARACTER DELAY bar code below. 2. Scan two bar codes from Numeric Bar Codes beginning on page 5-96 which represent the desired delay. You must always scan two bar codes. 3. If you make an error, or wish to change your selection, scan CANCEL on page 5-98.

<FN3>30C0C0063 INTERCHARACTER DELAY

5-91

Page 132

LS 6800 Product Reference Guide

Host Serial RTS Line State Scan a bar code below to set the host serial RTS line state to either high or low.

<FN3>1080040 HOST: LOW RTS

HOST: HIGH RTS <FN3>1080041

5-92

Page 133

Programming the LS 6800

Serial Response Timeout This parameter determines the maximum period allowed to elapse before the scanner assumes end of transmission. The delay period can range from 0 to 9.9 seconds. To set a serial (RS-232C) response time-out: 1. Scan the SERIAL RESPONSE TIME-OUT bar code below. 2. Scan two bar codes from Numeric Bar Codes beginning on page 5-96 which represent the desired time-out. You must always scan two bar codes. 3. If you make an error, or wish to change your selection, scan CANCEL on page 5-98.

<FN3>3090020063 SERIAL RESPONSE TIME-OUT

5-93

Page 134

LS 6800 Product Reference Guide

Beep on <BEL> When this parameter is enabled, the scanner issues a beep when a <BEL> character is detected on the RS-232C serial data line. <BEL> indicates an illegal entry or other important event. If this parameter is enabled and the system is in battery mode, a 100 ms delay is placed at the end of the decode transmission. Scan a bar code below to enable or disable this option.

<FN3>1080001 BEEP ON <BEL> CHARACTER

DO NOT BEEP ON <BEL> CHARACTER <FN3>1080000

5-94

Page 135

Programming the LS 6800

Flash Memory Programming The LS 6800 series scanners are equipped with flash memory, which can be updated by a field service technician or at a repair depot. Through this process, software revisions and features can be added easily to existing units.

FAT (Factory Acceptance Test) Mode Scanning this bar code reveals information about the scanner’s software configuration that may be useful during diagnostics. You must recycle power to return to normal functionality.

<FN3>FLASHMODE FLASH MODE

FINAL ACCEPTANCE TEST MODE <FN3>FATMODE

5-95

Page 136

LS 6800 Product Reference Guide

Numeric Bar Codes Use these bar codes when programming the following parameters: Code Lengths, Pause Duration, Decode Attempt Duration, Prefix/Suffix Values, Timeout Between Decodes, Intercharacter Delay, Serial Response Timeout.

<FN3>A0

3

2 <FN3>A2

5-96

<FN3>A1

1

<FN3>A3

0

Page 137

Programming the LS 6800

Numeric Bar Codes (Cont’d)

<FN3>A4

7

<FN3>A5

5

<FN3>A7

4

6 <FN3>A6

5-97

Page 138

LS 6800 Product Reference Guide

Numeric Bar Codes (Cont’d)

<FN3>A8

9

<FN3>A9

8

CANCEL <FN3>A-

5-98

Page 139

Programming the LS 6800

Special Macro PDF Features This section discusses programmable Macro PDF features supported by the LS 6800. Macro PDF concatenates multiple PDF symbols into one file. The LS 6800 decodes symbols that are encoded with this feature, however the 64K version cannot buffer large sets of Macro PDF symbols.

Caution When printing, keep each Macro PDF sequence separate, for each sequence has unique identifiers. Do not mix bar codes from several Macro PDF sequences, even if they encode the same data. When scanning Macro PDF sequences, scan the entire Macro PDF sequence without interruption. If you scan a mixed sequence, you get two long low beeps (Lo Lo) for inconsistent file ID or inconsistent symbology error. Before programming these special features, follow the physical setup instructions in Chapter 2, Setup, then program the required generic decode and data transmission parameters from Chapter 6, Advanced Data Formatting. Use the same programming method for setting Macro PDF features as used for standard features. Note that all parameter settings are stored in non-volatile memory and so are retained after power down.

5-99

Page 140

LS 6800 Product Reference Guide

Macro PDF Transmission / Decode Modes Select only one of the four options below for handling the decoding of Macro PDF. The decoder can handle up to 64K bytes of decoded data, including any optional field information, except in the mode Transmit Each Macro PDF Symbol Decoded in Sequential Order, where there is no limit to the size of the Macro PDF set. Select one of these four options for decoding Macro PDF sequences. t t t t

5-100

Buffer All Symbols / Transmit Macro PDF When Complete: This activates transmission of all decode data from an entire Macro PDF sequence. Transmission does not occur until the entire Macro PDF sequence is scanned and decoded. This is the default option. If the decode data exceeds the limit of 64K bytes, there is no transmission because the entire sequence has not been scanned. Use the parameter Flush Macro PDF Buffer to purge the buffer. Transmit Any Symbol in Set / No Particular Order: This causes transmission of data from each Macro PDF417 symbol as decoded, whether it is in sequential order or not. Scan in Sequence Only / Transmit in Sequence Without Buffering: This causes transmission of data from each symbol within the Macro PDF sequence as decoded, provided the Macro PDF symbols are scanned in order. If you do not scan the symbols in order, an error occurs. Buffer Scans Out of Order / Transmit Scans in Order: When enabled, decode data from each symbol within the Macro PDF sequence is transmitted when decoded, provided that the Macro PDF symbols are scanned in order. Decode data from symbols out of order in the Macro PDF sequence is buffered. The decoder can buffer up to 64K bytes.