Page 1
RS 2200/3200 LSSeries 5800
LS 5800 Mounting Instructions and EAS Antenna Kit Installation Guide
Quick Reference
Page 2
0
© 1998 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products. Symbol is a registered trademark of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No.4,360,798; 4,369,361; 4,387,297; 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,714,746; 5,723,851; 5,734,152; 5,734,153; D305,885; D341,584; D344,501; D359,483; D362,435; D363,700; D363,918; D370,478; D383,124; D391,250. Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan). European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/ 03938; Italy 1,138,713. rev. 4/98
Quick Reference
Page 3
1
Introduction The first part of this guide provides mounting information for all the different LS 5800 configurations. It shows a typical layout and furnishes mounting dimensions. The second part deals with installing an EAS system.
Mounting The LS 5800 mounts in the counter, with the face of the scanner either flush with the counter top or resting on it. In Figure 1, the dotted area depicts the active scan area, and the arrow shows the optimal direction of product flow. The scanner’s active scan zone extends about 6 in. (15.24 cm) above the window, and is angled at approximately 38° from the counter.
Product Flow symbol
Figure 1. Active Scan Area The LS 5800 is available with either a standard scratch-resistant coated glass, or a stainless steel top with a sapphire- or diamond-coated scan window. Each configuration can be mounted with the lip of the scanner resting either slightly above or flush with the counter top.
Page 4
2
Layout Figure 2 shows a typical LS 5800 installation. For best operating results, locate the power supply at least 4 in. (10.16 cm) below the scanner chassis or 2 in. (5.08 cm) away laterally.
Host I/F Cable LS 5800
~66.5 in. 1690 mm
~71.2 in. 1810 mm
Synapse Cable
Power Supply
Cable Routing
Figure 2. Typical LS 5800 Installation
Quick Reference
Page 5
3
Standard Scratch-Resistant Coated Glass There are two options for mounting the LS 5800-IxxxTN and LS 5800IxxxTC (standard scratch-resistant coated glass) with a 12-17206-xx bucket.
Option A - Resting on the counter top 1. Cut a hole in the counter 6.26 in. (159 mm) square (Figure 3).
Counter Hole
6.26 in. ±0.06 159 mm ±1.5
7.91 in. 201 mm
~3.5 in. 89 mm
Figure 3. Standard Glass Option A 2. Insert the bucket into the hole. 3. Place the scanner on the counter near the bucket. 4. Route the cables from beneath the bucket and attach to the scanner as shown in Figure 2. 5. Lower the scanner into the bucket.
Page 6
4
Standard Scratch-Resistant Coated Glass Option B - Flush with the counter top 1. On the counter top, measure two concentric squares: an inside square of 6.26 in. (159 mm), and an outside square of 7.91 in. (201 mm) (Figure 4). 2. Cut out the 6.26 in. (159 mm) inner square. 3. With a router set to a depth of .05 in. (1.2 mm), route out the outside square. The corner radius should not exceed 0.2 in. (5 mm).
Counter Hole
7.91 in. 201 mm
0.39 in min 10 mm min
7.91 in. min 201 mm min
0.05 in 1.2 mm
R 0.2 in. max R 5 mm max
6.26 in. ±0.06 159 mm ±1.5
~3.5 in. 89 mm
Figure 4. Standard Glass Option B
Quick Reference
Page 7
5
4. Insert the bucket into the hole. 5. Place the scanner on the counter near the bucket. 6. Route the cables from beneath the bucket and attach to the scanner as shown in Figure 2. 7. Lower the scanner into the bucket.
Page 8
6
Stainless Steel Top with Hardened Scan Windows The LS 5800-I210SN has a stainless steel top with a sapphirecoated glass. The LS 5800-I210DN has a stainless steel top with a diamondex-coated glass. There are two options for mounting the LS 5800 with a stainless steel top.
Option A - Resting on the counter top 1. Cut a hole in the counter 6.81 in. (173 mm) square (Figure 5).
Counter Hole
6.81 in. ±0.06 173 mm ±1.5
7.91 in. 201 mm
~3.5 in. 89 mm
Figure 5. Stainless Steel Top Option A 2. Route the cables from beneath the hole and attach to the scanner as shown in Figure 2. 3. Lower the scanner into the hole in the counter.
Quick Reference
Page 9
7
Stainless Steel Top with Hardened Scan Windows Option B - Flush with the counter top 1. On the counter top, measure two squares: an inside square of 6.81 in. (173 mm), and an outside square of 7.91 in. (201 mm) (Figure 6). 2. Cut out the 6.81 in. (173 mm) inner square. 3. With a router set to a depth of .05 in. (1.2 mm), route out the outside square. The corner radius should not exceed 0.20 in. (5 mm).
Counter Hole
7.91 in. 201 mm
0.39 in min 10 mm min
7.91 in. min 201 mm min
0.05 in 1.2 mm
R 0.20 in. max R 5 mm max
6.81 in. ±0.06 173 mm ±1.5
~3.5 in. 89 mm
Figure 6. Stainless Steel Top Option B
Page 10
8
4. Route the cables from beneath the hole and attach to the scanner as shown in Figure 2. 5. Lower the scanner into the hole in the counter.
Replacing Other Symbol Fixed-Mount Scanners LS 5100/LS 5400 with LS 5800-IxxxZN and LS 5800-I220SN 1. Remove the LS 5100/ LS 5400 scanner. 2. Place the LS 5800-IxxxZN or LS 5800-I220SN scanner on the counter near the hole. 3. Route the cables from beneath the hole and attach to the scanner as shown in Figure 2. 4. Lower the scanner into the hole.
Quick Reference