Page 43
Chapter 3 Setup BIOS Setup After the FMT1040 is booted, the Ethernet address and BIOS revision level appear on the first line of the 2 line by 40 character display. The second line displays "[ENTER]=setup" even if setup has been disabled. Figure 3-1 below shows a sample after-boot display. Unique Network Address
00-C0-52-xx-xx-xx [ENTER]=setup
BIOS Revision xx.xx
Specific Address & BIOS Version Numbers
Figure 3-1. First FMT1040 Screen Display After Bootup
A delay of a few seconds occurs before the system finishes the boot process. To enter into the setup process, press the <ENTER> key while the address and revision are displayed. Figure 3-2 shows a sample setup screen. Line 1 of the display indicates which setup screen and option are currently selected. Line 2 shows the currently saved options. The <ENTER> key accepts a setting and advances to the next setup screen. Option
Memory Option: A (640K Conv, 256K Ext) [ENTER]ACCEPTS [F8]Toggles [A ]
Saved Option
Figure 3-2. Memory Options Screen Using <F8> Key To Toggle Between Options 3-1
Page 44
FMT1040 Installation Guide
Pressing the following keys moves you through the setup screens and their option lists: <F5>
Moves you backward through setup screens.
<F6>
Moves you forward through setup screens without change.
<F7>
Moves you backward through option list.
<F8>
Moves you forward through option list.
<ENTER>
Accepts option setting and advances you to next setup screen.
BIOS Setup Screens After you press <ENTER> to get into the setup mode, you are presented with numerous setup screens to select options effecting display operation, memory configuration, boot type, etc. Details about the setup screens may be found on the network driver disk in a file named Readme.txt. After all setup screens have been viewed and choices made, the save options screen appears as shown in Figure 3-3. Confirm Setup [F2]=Abandon Changes
[F1]=Exit, Save [F8]=Exit, No Save
Figure 3-3. The Save Options Screen
Setup is now complete. Several options are available: • Press <F1>: Exit and save changes to EEPROM. (Changes appear every time the FMT1040 boots up.) • Press <F2>: Abandon changes. (Setup returns immediately to status in effect prior to entering setup.) • Press <F8>: Exit without saving changes to EEPROM. (Setup returns to status in effect prior to entering setup but remains in effect for current work session.)
3-2
Page 45
Setup
Network Setup Setup Parameters The FMT1040 boots onto your network as a diskless work station. The enclosed network driver diskette has the files that link the network operating system to the FMT1040.
Setup Steps 1. Create a boot image. A boot image must be created on your network's server. Please consult with your network manager to ensure that the boot image has been created and any other steps required to setup your server for booting diskless work stations have been completed. Refer to the FMT1000 Series Remote Boot Setup Guide (Symbol P/N 70-16672-01)and the FMT1000 Series TCP/IP Remote Boot Setup Guide (Symbol P/N 70-16673-01) for network specific connection information. 2. Connect the network cable. Use the 10BaseT cable to connect the FMT1040 10BaseT through the RJ45 connector. 3. Connect any barcode peripheral devices to the unit as shown in Figure 2-1. Note: You must connect bar code peripheral devices, especially lasers, before applying power to the FMT1040. 4. Connect Power. See page 2-3 for recommended power supply specifications. The FMT1040 goes through a series of tests and displays appropriate messages. When the FMT1040 receives its boot code, it may also contain applicationspecific information so a different prompt may be displayed with each FMT1040 after booting. See your network manager for information about what prompt will be displayed by each computer after booting. See the FMT1000 Series Programmer's Guide (Symbol P/N 70-16674-01) for information about other configurations, as well as for information about programming and using the FMT1020, including various built-in features.
3-3
Page 46
FMT1040 Installation Guide
Figure 3-4 shows a diagram of an FMT1040 network.
Figure 3-4. Network Setup Example Showing Use of Hub, Repeater and Multiple FMT1040 Computer Work Stations
See the FMT1000 Series Programmer's Guide, for information about other configurations. Programming and using the FMT1040, including various builtin features, will be explained in the programmer's guide. 3-4
Page 47
Setup
Standalone Setup The FMT1040 may be operated independent of a LAN by using a PCMCIA SRAM card. Data collected in this mode may be accessed via the RS-232 port. For the FMT1040 to boot the DOS operating system from a PCMCIA SRAM card, the card must be formatted as a system bootable card. We have provided some information below that may be helpful to you.
Creating a Bootable SRAM Card with an Adtron Drive FMT1040s have a Type I PCMCIA card slot. You can boot an FMT1040 series computer from a PC card, as with any DOS PC with a system formatted boot disk. There are two ways of obtaining a PCMCIA bootable SRAM card: purchase one ready-made or create one yourself. This section will outline the steps required to create a bootable PCMCIA card. The equipment used in these steps is as follows: • Adtron drive unit (Model SDD-R-PCC) • Adtron utility disk • SRAM card for Adtron drive (Epson 1 MB) • PC with a hard drive, COM1, floppy drive • One formattable 1.44 MB floppy diskette
The steps detailed here will allow you to create a bootable SRAM card. You will first connect the Adtron drive to the COM port on a PC that has both a hard drive and a floppy drive. Then you will create an ADTRON subdirectory on your hard drive. (This subdirectory is used to hold the files necessary to make the SRAM card bootable (e.g., command.com, io.sys, msdos.sys). An executable program from Adtron will be used to format the SRAM card and to move all the required files from the subdirectory onto the card. Once the SRAM card is ready to be used as a boot disk, you will connect the Adtron device with the bootable SRAM card to the COM1 port on the FMT1040 computer and select Adtron as the Boot ROM type during setup. 3-5
Page 48
FMT1040 Installation Guide
Procedures 1. Preparing your PC for Adtron drive access: a. Edit the CONFIG.SYS file on your PC and add the following line DEVICE=C:\ADTRON\SDDRPCC.SYS b. Create a subdirectory for use by Adtron. c:>MD ADTRON c. Change directories to the ADTRON subdirectory. C:\CD ADTRON d. Copy the files from the Adtron utility disk. (The drive letter may vary.) C:\ADTRON>COPY B:*.*
Reboot your PC. You should see a message that states that the Adtron device driver has successfully loaded. The drive reference for the Adtron drive will be the next available local drive letter. (We will use E: in these steps.) 2. Accessing the Adtron drive. Once the PC recognizes the new drive you can access it like any other drive on your computer. (If you are connected to a network, you may experience a conflict with your logical network drive overriding the local drive.) If you try to read the card in the Adtron drive (i.e., DIR E:) before you have formatted the PCMCIA card, you will get a standard error reading drive message from DOS. 3. Creating system boot files for the Adtron. There are two differences between a disk that is bootable and one that is not. The bootable disk has a boot sector and three system files - two hidden (IO.SYS, MSDOS.SYS) and one visible (COMMAND.COM). For the CMGRC program to create a bootable disk, the files and boot sector information must be accessible in the Adtron directory. a. Create a bootable floppy disk.
3-6
Page 49
Setup
Insert floppy disk into drive A. (The drive letter may vary.) Format the floppy disk as a system floppy disk: C:>FORMAT A:/S b. Copy the boot sector information. Use the Adtron CPYBOOT utility to create a boot sector file. C:\ADTRON.CPYBOOT A: BOOT.DAT c. Copy the hidden files. Use the Adtron CPYHDN utility to copy the two hidden I/O and DOS system files, IO.SYS and MSDOS.SYS. (These names depend on the maker of your DOS - see your DOS manual). You will need to run the utility once for each file. C:\ADTRON>CPYHDN At the prompt: ENTER HIDDEN FILE TO COPY: respond by entering: A.IO.SYS At the prompt: ENTER DESTINATION FILE: respond by entering IO.SYS C:\ADTRON>CPYHDN At the prompt: ENTER HIDDEN FILE TO COPY: respond by entering: A.MSDOS.SYS At the prompt: ENTER DESTINATION FILE: respond by entering MSDOS.SYS d. Copy the command.com file Copy COMMAND.COM from the floppy disk to the Adtron subdirectory. C:\ADTRON>COPY A:COMMAND.COM
3-7
Page 50
FMT1040 Installation Guide
4. File verification Before you run the format command, the following files must be available in the Adtron directory: BOOT.DAT IO.SYS
COMMAND.COM MSDOS.SYS
5. Formatting a PCMCIA bootable system disk The following command may be typed in at the command line, or it may be run from a .BAT file. The parameters are for a 1 MB disk. Refer to the Adtron documentation for any other configuration. C:\ADTRON>cmgrc -f -tsram05 -d240,4,8,2 -yaboot.dat ic:,io.sys,msdos.sys,command.com e:
Your Adtron card is now bootable from the FMT1040. 6. Setting up the FMT1040 for an Adtron boot. a. Remove the PC card from the Adtron unit and put it into the FMT1040. b. Power on the FMT1040. c. Press <enter> on the FMT1040 and go into Setup mode. d. Set the PCMCIA card slot to enable. If you don’t have a monitor, be sure you enable distrack with a 2x40 CF configuration. Set the boot priority to local. e. At the save option, press F1 to save and exit. When the boot process has completed, you should see an A prompt on the FMT1040 screen. You can create CONFIG.SYS and AUTOEXEC.BAT files as necessary for your application.
3-8