Page 27
Electrical Installation
Auxiliary RS-232 SmartPort The auxiliary RS-232 connector is a six-pin RJ12 modular phone jack type connector. This port provides access for serial devices. (See Figure 2-9.)
Pin # Function 1
GND
2
TX
3
RX
4
RTS
5
CTS
6
+5 V
Figure 2-9. Pinout Table for the RJ12 Connector
2-9
Page 28
FMT1040 Installation Guide
Auxiliary RS-232 SmartPort Interface Cable An interface cable (P/N 59-16251-01) converts the RJ12 connector to a male DB25 connector for the FMT1040. The interface cable and pinout are shown in Figure 2-10.
Pin #
Function
Pin #
Function
Pin #
Function
1
N/C
10
N/C
18
N/C
2
TX
11
N/C
19
N/C
3
RX
12
N/C
20
N/C
4
RTS
13
N/C
21
N/C
5
CTS
14
N/C
22
N/C
6
N/C
15
N/C
23
N/C
7
GND
16
N/C
24
N/C
8
N/C
17
N/C
25
N/C
9
+5V
Figure 2-10. Six-Pin to DB25 interface Cable and Pinout Table
2-10
Page 29
Electrical Installation
Bar Code Input Ports (2) The FMT1040 provides two ports for bar code inputs. The main port is a DE9 connector with locking tabs. Most peripherals supplied by Intelligent Instrumentation will connect to this port. The secondary connector is a five-pin header. The built-in bar code slot or magnetic stripe reader connects to the five-pin header. Both pinouts follow as Figure 2-11 and Figure 2-12. Note: A magnetic stripe device may be installed into either port. If you want to connect a bar code device and a magnetic stripe, we recommend connecting the bar code to the nine-pin connector. 1
2
6
3
7
4
8
5
9
Pin #
Function
1
+5V (VIA 2.2K pullup)
2
Bar Code Input
3
Bar Code 2/Mag Data
4
GND
5
Mag Card Present
6
V Source (+12V)
7
GND
8
Mag Clock
9
+5V
Figure 2-11. Pinout Table for DE9 Connector
2-11
Page 30
FMT1040 Installation Guide
1
2
Pin #
3
4
5
Function
1
GND
2
Bar Code 2/Mag Data
3
+5V
4
Mag Clock
5
GND
Figure 2-12. Pinout Table for Five-Pin Header
2-12
Page 31
Electrical Installation
Input/Output Connector (I/O) The input/output connector provides access to the two isolated inputs and relay outputs. The line functions are shown in Table 2-1. Table 2-1. Pinout Table for Input/Output Connector Line #
Function
Line #
Function
1
IN 1 (+)
8
Ground
2
IN 1 (-)
9
OUT 1 (Normally Closed)
3
IN 2 (+)
10
OUT 1 (COMMON)
4
IN 2 (-)
11
OUT 1 (Normally Open)
5
Vsource (+12 V)
12
OUT 2 (Normally Closed)
6
Ground
13
OUT 2 (COMMON)
7
Ground
14
OUT 2 (Normally Open)
The 14-pin input/output connector is shown in Figure 2-13 with a schematic showing details of the FMT1040 I/O circuit. The connector is shown here and elsewhere as it appears physically and as a diagram.
2-13
Page 32
FMT1040 Installation Guide
Figure 2-13. The 14-Pin Input/Output Connector and Related FMT1040 Schematic
2-14
Page 33
Electrical Installation
Digital Inputs Digital inputs may be used in one of two modes: • Sensing DC voltage • Sensing contact closure.
DC Voltage Inputs Two optically isolated digital inputs may be used to sense DC voltages from 3 to 30 VDC. Also, the digital input channels count pulses. The cable shield, if present, may be connected to one of the return terminals on the connector as illustrated below. Figure 2-14 illustrates the FMT1040 circuitry dedicated to sensing DC voltage inputs.
Figure 2-14. FMT1040 Schematic Showing DC Voltage Sensing
2-15
Page 34
FMT1040 Installation Guide
Dry Contact Use The digital inputs may also be used to sense contact closures of devices such as relays, limit switches, photocells, etc. Wetting current is provided on the connector. This current source is nonisolated; however, an external isolated supply may be used if truly isolated contact inputs are required. Figure 2-15 illustrates the FMT1040 circuitry dedicated to sensing contact closure.
Figure 2-15. FMT1040 Schematic Showing Contact Closure Sensing
2-16