Page 39
Mai Technical fo
Specifications
Introduction 20... nee ete e nents 3-3 Maintenance .... 0.2.0... nent bt e ete e tenes 3-3 Troubleshooting ............0 0.00 e tent e ee ee 3-3 Technical Specifications .. 0... nee e nen enn tenn tenes 3-5
Digital Scanner Signal Descriptions 0.0.00... ccc nent n enn ees 3-6
Page 40
3-2 DS6608 Product Reference Guide
Page 41
Maintenance and Technical Specifications 3-3
Introduction This chapter provides suggested scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts).
Maintenance Cleaning the scan window is the only maintenance required. A dirty window can affect scanning accuracy. • • • •
Do not allow abrasive material to touch the window. Remove any dirt particles with a damp cloth. Wipe the window using a tissue moistened with ammonia/water. Do not spray water or other cleaning liquids directly into the window.
Troubleshooting Table 3-1. Troubleshooting Problem The aiming pattern does not appear when pressing the trigger.
Possible Causes
Possible Solutions
No power to the digital scanner.
If the configuration requires a power supply, re-connect the power supply.
Incorrect host interface cable is used.
Connect the correct host interface cable.
Interface/power cables are loose.
Re-connect cables.
Digital scanner is disabled.
For Synapse or IBM 468x mode, enable the digital scanner via the host interface. Otherwise, see the technical person in charge of scanning.
If using RS-232 Nixdorf B mode, CTS is not asserted. Assert CTS line. Aiming pattern is disabled.
Enable the aiming pattern. See Decode Aiming Pattern on page 5-5.
Scanner emits short low/short medium/short high The USB bus may put the digital scanner in a state Normal during host reset. beep sequence (power-up beep sequence) more than where power to the digital scanner is cycled on and once. off more than once. Digital scanner emits aiming pattern, but does not decode the bar code.
Digital scanner is not programmed for the correct bar Program the digital scanner to read that type of bar code type. code. See Chapter 13, Symbologies. Bar code symbol is unreadable.
Scan test symbols of the same bar code type to determine if the bar code is defaced.
The symbol is not completely inside aiming pattern. Move the symbol completely within the aiming pattern. Digital scanner emits 4 short high beeps during decode attempt.
Digital scanner has not completed USB initialization. Wait several seconds and scan again.
Page 42
3-4 DS6608 Product Reference Guide
Table 3-1. Troubleshooting (Continued) Problem Digital scanner decodes bar code, but does not transmit the data to the host.
Possible Causes
Possible Solutions
Digital scanner is not programmed for the correct host type.
Scan the appropriate host type programming bar code. See the chapter corresponding to the host type.
Interface cable is loose.
Re-connect the cable.
If 4 long low beeps are heard, a transmission error occurred.
Set the digital scanner's communication parameters to match the host's setting.
If 5 low beeps are heard, a conversion or format error Configure the digital scanner's conversion occurred. parameters properly.
Host displays scanned data incorrectly.
If lo/hi/lo beeps are heard, an invalid ADF rule is detected.
Program the correct ADF rules.
If hi/lo beeps are heard, the digital scanner is buffering Code 39 data.
Normal scanning a Code 39 bar code and the Code 39 Buffering option is enabled.
Digital scanner is not programmed to work with the Scan the appropriate host type programming bar host. code. For RS-232, set the digital scanner's communication parameters to match the host's settings. For a Keyboard Wedge configuration, program the system for the correct keyboard type, and turn off the CAPS LOCK key. Program the proper editing options (e.g., UPC-E to UPC-A Conversion).
Digital scanner emits hi/hi/hi/Lo beeps when not in RS-232 receive error. use.
Normal during host reset. Otherwise, set the digital scanner's RS-232 parity to match the host setting.
Digital scanner emits lo/hi beeps during programming.
Input error or Cancel bar code was scanned.
Scan the correct numeric bar codes within range for the parameter programmed.
Digital scanner emits lo/hi/lo/hi beeps during programming.
Out of ADF parameter storage space.
Erase all rules and re-program with shorter rules.
Out of Synapse parameter storage space.
Scan Set Synapse Defaults bar code for cables no longer in use and re-program the digital scanner for the current host interface.
Digital scanner emits lo/hi/lo beeps.
Clearing Code 39 buffer.
Normal when scanning the Code 39 Buffering Clear Buffer bar code or upon attempt to transmit an empty Code 39 buffer.
Digital scanner emits a power-up beep after changing USB host type.
The USB bus re-established power to the digital scanner.
Normal when changing USB host type.
Digital scanner emits one high beep when not in use. In RS-232 mode, a <BEL> character was received and Beep on <BEL> option is enabled.
Normal when Beep on <BEL> is enabled and the digital scanner is in RS-232 mode.
If after performing these checks the digital scanner still experiences problems, contact the distributor or call the local Symbol Support Center. See page xvi for the telephone numbers.
Note
Page 43
Maintenance and Technical Specifications 3-5
Technical Specifications Table 3-2. Technical Specifications Item
Description
Power Requirements
5 VDC + / - 10% @ approximately 220 mA RMS (nominal), 500 mA (max)
Power Source
Depending on host: • Host powered • External power supply, 5.2 V nominal
Decode Capability
UPC/EAN, UPC/EAN with supplementals, UCC/EAN, JAN 8 & 13, 128, Code 39, Code 39 Full ASCII, Code 39 Trioptic, Codabar (NW7), Interleaved 2 of 5, Discrete 2 of 5, IATA 2 of 5, Code 128, Code 93, MSI, Code 11, Code 32, Coupon Code, Bookland EAN, RSS, US Postnet, US Planet, UK Postal, Japan Postal, Australia Postal, Dutch Postal, Composite Codes, PDF417, MicroPDF, Maxicode, Data Matrix (ECC 200), QR Code.
Beeper Operation
User-selectable: enable, disable
Beeper Volume
User-selectable: three levels
Beeper Tone
User-selectable: three tones
Yaw Tolerance
± 50° from normal
Pitch Tolerance
± 60° from normal
Roll Tolerance
± 180° from normal
Print Contrast Minimum
25% minimum reflectance differential, measured at 650 nm.
Ambient Light Immunity
10,000 Ft Candles (107,600 Lux)
Durability
6 ft (1.8 m) drop to concrete
Operating Temperature
32° to 122° F (0° to 50° C)
Storage Temperature
-40° to 158° F (-40° to 70° C)
Humidity
5% to 95% (non-condensing)
Weight (without cable)
6.4 oz. (181.4 g)
Dimensions: Height Width Depth
6.55 in. (16.64 cm) 2.82 in. (7.16 cm) 4.72 in. (11.99 cm)
Laser
650nm laser diode
Laser Classifications
IEC 825-1 Class 2
ESD
15 kV area discharge 8 kV contact discharge
Minimum Element Width
5 mil (0.127 mm)
Interfaces Supported
RS-232, Keyboard Wedge, Wand Emulation, Scanner Emulation, IBM 468X/469X, USB, Synapse
Electrical Safety
UL1950, CSA C22.2 No.950. EN60950/IC950
Input Transient Protection
IEC 1000-4-(2,3,4,5,6,11)
EMI
FCC Part 15 Class B, ICES-003 Class B European Union EMC Directive, Japan VCCI/MITI/Dentori
Page 44
3-6 DS6608 Product Reference Guide
Digital Scanner Signal Descriptions Bottom of digital scanner
Cable interface port
Pin 1
Pin 10
Interface cable modular connector
Figure 3-1. Digital Scanner Cable Pinouts The signal descriptions in Table 3-3 apply to the connector on the digital scanner and are for reference only.
Table 3-3. Digital Scanner Signal Pin-outs Pin
IBM
Synapse
RS-232
Keyboard Wedge
Wand
Scanner Emulation
USB
1
Reserved
SynClock
Reserved
Reserved
Reserved
Jump to Pin 6
DBP
2
Power
Power
Power
Power
Power
Power
Power
3
Ground
Ground
Ground
Ground
Ground
Ground
Ground
4
IBM_A(+)
Reserved
TxD
KeyClock
DBP
Reserved
SOS
5
Reserved
Reserved
RxD
TermData
CTS
D+
Decode
6
IBM_B(-)
SynData
RTS
KeyData
RTS
Jump to Pin 1
Trigger
7
Reserved
Reserved
CTS
TermClock
Reserved
D-
Enable
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
9
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
10
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved