The text of a manual · part 43 of 50
DS6608 Product Reference Guide: Standard Default Parameters
Pages 343 to 352 of 402, from DS6608 Product Reference Guide
The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol DS-6608
Page 343
Standard Default Parameters
Page 344
A-2 DS6608 Product Reference Guide
Page 345
Standard Default Parameters
Table A-1. Standard Default Parameters Table Parameter
Parameter Number
Default
Page Number
User Preferences Set Default Parameter
All Defaults
4-5
Parameter Scanning
ECh
Enable
4-5
Beeper Tone
91h
Medium
4-6
Beeper Volume
8Ch
High
4-7
Power Mode
80h
Continuous On
4-7
Time Delay to Low Power Mode
92h
1 Minute
4-8
Trigger Mode
8Ah
Auto Aim
4-9
Picklist Mode
F0h 92h
Disabled Always
4-10
Decode Session Timeout
88h
9.9 Sec
4-11
Timeout Between Decodes, Same Symbol
89h
0.6 Sec
4-11
Beep After Good Decode
38h
Enable
4-12
Decoding Illumination
F0h 2Ah
Enable
5-5
Decode Aiming Pattern
F0h 32h
Enable
5-5
Keyboard Wedge Host Type
IBM PC/AT& IBM PC Compatibles1
6-5
Country Types (Country Codes)
North American
6-6
Ignore Unknown Characters
Transmit
6-8
Keystroke Delay
No Delay
6-8
Intra-Keystroke Delay
Disable
6-9
Alternate Numeric Keypad Emulation
Disable
6-9
Caps Lock On
Disable
6-10
Caps Lock Override
Disable
6-10
Convert Wedge Data
No Convert
6-11
Decoding Preferences
Keyboard Wedge Host Parameters
1User selection is required to configure this interface and this is the most common selection.
A-3
Page 346
A-4 DS6608 Product Reference Guide
Table A-1. Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
Function Key Mapping
Disable
6-11
FN1 Substitution
Disable
6-12
Send and Make Break
Send
6-12
RS-232 Host Types
Standard1
7-8
Baud Rate
9600
7-9
Parity Type
None
7-11
Stop Bit Select
1 Stop Bit
7-12
Data Bits
8-Bit
7-12
Check Receive Errors
Enable
7-13
Hardware Handshaking
None
7-14
Software Handshaking
None
7-16
Host Serial Response Time-out
2 Sec
7-17
RTS Line State
Low RTS
7-18
Beep on <BEL>
Disable
7-18
Intercharacter Delay
0 msec
7-19
Nixdorf Beep/LED Options
Normal Operation
7-20
Ignore Unknown Characters
Send Bar Code
7-20
USB Device Type
HID Keyboard Emulation
8-5
USB Country Keyboard Types (Country Codes)
North American
8-6
USB Keystroke Delay
No Delay
8-8
USB CAPS Lock Override
Disable
8-8
USB Ignore Unknown Characters
Enable
8-9
Emulate Keypad
Disable
8-9
Emulate Keypad with Leading Zero
Disable
8-10
USB Keyboard FN1 Substitution
Disable
8-10
RS-232 Host Parameters
USB Host Parameters
1User selection is required to configure this interface and this is the most common selection.
Page 347
Standard Default Parameters
Table A-1. Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
Function Key Mapping
Disable
8-11
Simulated Caps Lock
Disable
8-11
Convert Case
No Case Conversion
8-12
Port Address
None Selected
9-5
Convert Unknown to Code 39
Disable
9-6
Wand Emulation Host Types
Symbol OmniLink Interface Controller1
10-5
Leading Margin
80 msec
10-6
Polarity
Bar High/Margin Low
10-7
Ignore Unknown Characters
Ignore
10-8
Convert All Bar Codes to Code 39
Disable
10-8
Convert Code 39 to Full ASCII
Disable
10-9
Beep Style
Beep on Successful Transmit
11-5
Parameter Pass-Through
Parameter Process and Pass Through
11-6
Convert Newer Code Types
Convert Newer Code Types
11-7
Module Width
20 µs
11-8
Convert All Bar Codes to Code 39
Do Not Convert to Code 39
11-8
Code 39 Full ASCII Conversion
Disable
11-9
Transmission Timeout
3 seconds
11-9
Ignore Unknown Characters
Ignore Unknown Characters
11-11
Leading Margin
2 ms
11-12
Check for Decode LED
Check for Decode LED
11-13
None1
12-3
IBM 468X/469X Host Parameters
Wand Emulation Host Parameters
Undecoded Scanner Emulation
123Scan Configuration Tool 123Scan Configuration UPC/EAN 1User selection is required to configure this interface and this is the most common selection.
A-5
Page 348
A-6 DS6608 Product Reference Guide
Table A-1. Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
UPC-A
01h
Enable
13-10
UPC-E
02h
Enable
13-10
UPC-E1
0Ch
Disable
13-11
EAN-8/JAN 8
04h
Enable
13-11
EAN-13/JAN 13
03h
Enable
13-12
Bookland EAN
53h
Disable
13-12
Decode UPC/EAN/JAN Supplementals (2 and 5 digits)
10h
Ignore
13-13
UPC/EAN/JAN Supplemental Redundancy
50h
10
13-14
Transmit UPC-A Check Digit
28h
Enable
13-15
Transmit UPC-E Check Digit
29h
Enable
13-15
Transmit UPC-E1 Check Digit
2Ah
Enable
13-16
UPC-A Preamble
22h
System Character
13-16
UPC-E Preamble
23h
System Character
13-17
UPC-E1 Preamble
24h
System Character
13-18
Convert UPC-E to A
25h
Disable
13-18
Convert UPC-E1 to A
26h
Disable
13-19
EAN-8/JAN-8 Extend
27h
Disable
13-19
UCC Coupon Extended Code
55h
Disable
13-20
Code 128
08h
Enable
13-20
UCC/EAN-128
0Eh
Enable
13-21
ISBT 128
54h
Enable
13-21
Code 39
00h
Enable
13-22
Trioptic Code 39
0Dh
Disable
13-22
Convert Code 39 to Code 32 (Italian Pharmacy Code)
56h
Disable
13-23
Code 32 Prefix
E7h
Disable
13-23
Code 128
Code 39
1User selection is required to configure this interface and this is the most common selection.
Page 349
Standard Default Parameters
Table A-1. Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
Set Length(s) for Code 39
12h 13h
2 to 55
13-24
Code 39 Check Digit Verification
30h
Disable
13-25
Transmit Code 39 Check Digit
2Bh
Disable
13-26
Code 39 Full ASCII Conversion
11h
Disable
13-26
Buffer Code 39
71h
Disable
13-27
Code 93
09h
Disable
13-29
Set Length(s) for Code 93
1Ah 1Bh
4 to 55
13-30
Code 11
0Ah
Disable
13-31
Set Lengths for Code 11
1Ch 1Dh
4 to 55
13-32
Code 11 Check Digit Verification
34h
Disable
13-33
Transmit Code 11 Check Digit(s)
2Fh
Disable
13-34
Interleaved 2 of 5 (ITF)
06h
Enable
13-34
Set Lengths for I 2 of 5
16h 17h
14
13-35
I 2 of 5 Check Digit Verification
31h
Disable
13-36
Transmit I 2 of 5 Check Digit
2Ch
Disable
13-37
Convert I 2 of 5 to EAN 13
52h
Disable
13-37
Discrete 2 of 5
05h
Disable
13-38
Set Length(s) for D 2 of 5
14h 15h
12
13-38
Codabar
07h
Disable
13-39
Set Lengths for Codabar
18h 19h
5 to 55
13-40
CLSI Editing
36h
Disable
13-41
NOTIS Editing
37h
Disable
13-41
Code 93
Code 11
Interleaved 2 of 5 (ITF)
Discrete 2 of 5 (DTF)
Codabar (NW - 7)
1User selection is required to configure this interface and this is the most common selection.
A-7
Page 350
A-8 DS6608 Product Reference Guide
Table A-1. Standard Default Parameters Table (Continued) Parameter
Parameter Number
Default
Page Number
MSI MSI
0Bh
Disable
13-42
Set Length(s) for MSI
1Eh 1Fh
1 to 55
13-42
MSI Check Digits
32h
One
13-43
Transmit MSI Check Digit
2Eh
Disable
13-44
MSI Check Digit Algorithm
33h
Mod 10/Mod 10
13-44
US Postnet
59h
Enable
13-45
US Planet
5Ah
Enable
13-45
UK Postal
5Bh
Enable
13-46
Transmit UK Postal Check Digit
60h
Enable
13-46
Japan Postal
F0h 22h
Enable
13-47
Australian Postal
F0h 23h
Enable
13-47
Dutch Postal
F0h 46h
Enable
13-48
Transmit US Postal Check Digit
5Fh
Enable
13-48
RSS 14
F0h 52h
Enable
13-49
RSS Limited
F0h 53h
Enable
13-49
RSS Expanded
F0h 54h
Enable
13-50
Convert RSS to UPC/EAN
F0h 8Dh
Disable
13-50
Composite CC-C
F0h 55h
Disable
13-51
Composite CC-A/B
F0h 56h
Disable
13-51
Composite TLC-39
F0h 73h
Disable
13-52
UPC Composite Mode
F0h 58h
Always Linked
13-53
Composite Beep Mode
F0h 8Eh
Beep As Each Code Type is Decoded
13-54
Postal Codes
RSS (Reduced Space Symbology)
Composite
1User selection is required to configure this interface and this is the most common selection.
Page 351
Standard Default Parameters
Table A-1. Standard Default Parameters Table (Continued) Parameter UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes
Parameter Number
Default
Page Number
F0h ABh
Disable
13-54
PDF417
0Fh
Enable
13-55
MicroPDF417
E3h
Disable
13-55
Code 128 Emulation
7Bh
Disable
13-56
Data Matrix
F0h 24h
Enable
13-57
Maxicode
F0h 26h
Enable
13-57
QR Code
F0h 25h
Enable
13-58
Redundancy Level
4Eh
1
13-59
Security Level
4Dh
1
13-61
Intercharacter Gap Size
F0h 7Dh
Normal
13-62
2D Symbologies
Symbology-Specific Security Levels
Report Version
13-62
Macro PDF Flush Macro PDF Buffer
13-63
Abort Macro PDF Entry
13-63
Miscellaneous Scanner Options Transmit Code ID Character
2Dh
None
14-5
Prefix Value
63h, 69h
7013 <CR><LF>
14-6
Suffix 1 Value Suffix 2 Value
62h, 68h 64h, 6Ah
7013 <CR><LF>
14-6
Scan Data Transmission Format
EBh
Data as is
14-7
FN1 Substitution Values
67h, 6Dh
Set
14-8
Transmit “No Read” Message
5Eh
Disable
14-9
Synapse Interface
F0h ACh
Standard
14-10
1User selection is required to configure this interface and this is the most common selection.
A-9
Page 352
A-10 DS6608 Product Reference Guide