Page 229
Miscellaneous Scanner Options Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-3 Scanning Sequence Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-3 Errors While Scanning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-3 Miscellaneous Scanner Parameter Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-4 Miscellaneous Scanner Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-5 Transmit Code ID Character . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-5 Prefix/Suffix Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-6 Scan Data Transmission Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-7 FN1 Substitution Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-8 Transmit “No Read” Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-9 Synapse Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-10
Page 230
14-2 DS6608 Product Reference Guide
Page 231
Miscellaneous Scanner Options 14-3
Introduction This chapter includes commonly used bar codes to customize how data is transmitted to the host device. See Chapter 15, Advanced Data Formatting for further customization options. The digital scanner ships with the settings shown in the Miscellaneous Scanner Options Default Table on page 14-4 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous scanner defaults). If the default values suit requirements, programming is not necessary. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner is powered down.
Note
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
If not using a Synapse or USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host. To return all features to default values, scan the *Set All Defaults bar code on page 4-5. Throughout the programming bar code menus, default values are indicated with asterisks (*).
* Indicates Default
*Disable No Read
Feature/Option
(00h) Hex Value
Scanning Sequence Examples In most cases, scan one bar code to set a specific parameter value. Other parameters, such as Prefix Value, require scanning several bar codes. See each parameter for descriptions of this procedure.
Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Page 232
14-4 DS6608 Product Reference Guide
Miscellaneous Scanner Parameter Defaults Table 14-1 lists the defaults for miscellaneous scanner options parameters. To change any option, scan the appropriate bar code(s) provided in the Miscellaneous Scanner Parameters on page 14-5. See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Note Table 14-1. Miscellaneous Scanner Options Default Table Parameter
Parameter Number
Default
Page Number
Transmit Code ID Character
2Dh
None
14-5
Prefix Value
63h, 69h
7013 <CR><LF>
14-6
Suffix 1 Value Suffix 2 Value
62h, 68h 64h, 6Ah
7013 <CR><LF>
14-6
Scan Data Transmission Format
EBh
Data as is
14-7
FN1 Substitution Values
67h, 6Dh
Set
14-8
Transmit “No Read” Message
5Eh
Disable
14-9
Synapse Interface
F0h ACh
Standard
14-10
Page 233
Miscellaneous Scanner Options 14-5
Miscellaneous Scanner Parameters Transmit Code ID Character Parameter # 2Dh A Code ID character identifies the code type of a scanned bar code. This is useful when the digital scanner is decoding more than one code type. In addition to any single character prefix already selected, the Code ID character is inserted between the prefix and the decoded symbol. Select no Code ID character, a Symbol Code ID character, or an AIM Code ID character. For Code ID Characters, see Symbol Code Identifiers on page B-3 and AIM Code Identifiers on page B-4.
Symbol Code ID Character (02h)
AIM Code ID Character (01h)
*None (00h)
Page 234
14-6 DS6608 Product Reference Guide
Prefix/Suffix Values Key Category Parameter # P = 63h, S1 = 62h, S2 = 64h Decimal Value Parameter # P = 69h, S1 = 68h, S2 = 6Ah A prefix and/or one or two suffixes can be appended to scan data for use in data editing. To set a value for a prefix or suffix, scan a four-digit number (i.e., four bar codes from Appendix D, Numeric Bar Codes) that corresponds to that value. See Table E-1 on page E3 for the four-digit codes. When using host commands to set the prefix or suffix, set the key category parameter to 1, then set the 3-digit decimal value. See Table E-1 on page E-3 for the four-digit codes. To correct an error or change a selection, scan Cancel on page D-4. To use Prefix/Suffix values, first set the Scan Data Transmission Format on page 14-7.
Note
Scan Prefix (07h)
Scan Suffix 1 (06h)
Scan Suffix 2 (08h)
Data Format Cancel
Page 235
Miscellaneous Scanner Options 14-7
Scan Data Transmission Format Parameter # EBh To change the scan data format, scan one of the following eight bar codes corresponding to the desired format. If using this parameter do not use ADF rules to set the prefix/suffix.
Note
To set values for the prefix and/or suffix, see Prefix/Suffix Values on page 14-6.
*Data As Is (00h)
<DATA> <SUFFIX 1> (01h)
<DATA> <SUFFIX 2> (02h)
<DATA> <SUFFIX 1> <SUFFIX 2> (03h)
<PREFIX> <DATA > (04h)
Page 236
14-8 DS6608 Product Reference Guide
Scan Data Transmission Format (continued)
<PREFIX> <DATA> <SUFFIX 1> (05h)
<PREFIX> <DATA> <SUFFIX 2> (06h)
<PREFIX> <DATA> <SUFFIX 1> <SUFFIX 2> (07h)
FN1 Substitution Values Key Category Parameter # 67h Decimal Value Parameter # 6Dh The Wedge and USB HID Keyboard hosts support a FN1 Substitution feature. When enabled any FN1 character (0x1b) in an EAN128 bar code is substituted with a value. This value defaults to 7013 (Enter Key). When using host commands to set the FN1 substitution value, set the key category parameter to 1, then set the 3-digit keystroke value. See the ASCII Character Set table for the currently installed host interface for the desired value. To select a FN1 substitution value via bar code menus: 1. Scan the bar code below.
Set FN1 Substitution Value
2. Look up the keystroke desired for FN1 Substitution in the ASCII Character Set table for the currently installed host interface. Enter the 4-digit ASCII Value by scanning each digit in Appendix D, Numeric Bar Codes. To correct an error or change the selection, scan Cancel. To enable FN1 substitution for keyboard wedge, scan the Enable FN1 Substitution bar code on page 6-12. To enable FN1 substitution for USB HID keyboard, scan the Enable FN1 Substitution bar code on page 8-10.
Page 237
Miscellaneous Scanner Options 14-9
Transmit “No Read” Message Parameter # 5Eh Scan a bar code below to select whether or not to transmit a No Read message. When enabled, the characters NR are transmitted when a bar code is not decoded. When disabled, if a symbol does not decode, nothing is sent to the host.
Enable No Read (01h)
*Disable No Read (00h)
Page 238
14-10 DS6608 Product Reference Guide
Synapse Interface Parameter # F0h, ACh The auto-detection of a Synapse cable varies in duration depending on the type of Synapse connection. If a digital scanner is connected to another scanner using a Synapse cable, use the Auxiliary Synapse Port connection. In all other cases, where the cable is used, the default setting is recommended. To disconnect and reconnect the digital scanner from a Synapse cable that is connected to a live host via a Synapse, use the "Plug and Play" setting. Do not change this setting from the default if an on-board wedge host is enabled.
*Standard Synapse Connection (01h)
Auxiliary Synapse Port Connection (32h)